72
Views
0
CrossRef citations to date
0
Altmetric
Review

Pacemaker and Defibrillator Therapy in Pediatrics and Congenital Heart Disease

Pages 469-479 | Published online: 26 Aug 2008

Bibliography

  • DeFrances CJ , CullenKA, KozakLJ: National Hospital Discharge Survey: 2005 annual summary with detailed diagnosis and procedure data.Vital Health Stat., 13(165), 1–209 (2007).
  • Silka MJ , KronJ, DunniganA, DickM 2nd: Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society. Circulation, 87(3), 800–807 (1993).
  • Gregoratos G , AbramsJ, EpsteinAEet al.: ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). Circulation, 106(16), 2145–2161 (2002).
  • Epstein AE , DiMarcoJP, EllenbogenKAet al.: ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. Circulation, 117(21), E350–E408 (2008).
  • Batra AS , BalajiS: Pacing in adults with congenital heart disease.Expert Rev. Cardiovasc. Ther., 4(5), 663–670 (2006).
  • Bae EJ , LeeJY, NohCI, KimWH, KimYJ: Sinus node dysfunction after Fontan modifications – influence of surgical method.Int. J. Cardiol., 88(2–3), 285–291 (2003).
  • Andersen HO et al. , de Leval MR, Tsang VT : Is complete heart block after surgical closure of ventricular septum defects still an issue? Ann. Thorac. Surg., 82(3), 948–956 (2006).
  • Gross GJ , ChiuCC, HamiltonRM, Kirsh JA, Stephenson EA: Natural history of postoperative heart block in congenital heart disease: implications for pacing intervention. Heart Rhythm, 3(5), 601–604 (2006).
  • Hokanson JS , MollerJH: Significance of early transient complete heart block as a predictor of sudden death late after operative correction of tetralogy of Fallot.Am. J. Cardiol., 87(11), 1271–1277 (2001).
  • Batra AS , WellsWJ, HinokiKW, Stanton RA, Silka MJ: Late recovery of atrioventricular conduction after pacemaker implantation for complete heart block associated with surgery for congenital heart disease. J. Thorac. Cardiovasc. Surg., 125(6), 1291–1293 (2003).
  • Bruckheimer E , BerulCI, KopfGSet al.: Late recovery of surgically-induced atrioventricular block in patients with congenital heart disease. J. Interv. Card. Electrophysiol., 6(2), 191–195 (2002).
  • Robinson JD , ZimmermanFJ, De Loera O, Heitschmidt M, Hijazi ZM: Cardiac conduction disturbances seen after transcatheter device closure of muscular ventricular septal defects with the Amplatzer occluder. Am. J. Cardiol., 97(4), 558–560 (2006).
  • Carminati M , ButeraG, ChessaMet al.: Transcatheter closure of congenital ventricular septal defects: results of the European Registry. Eur. Heart J., 28(19), 2361–2368 (2007).
  • Donofrio MT , GullquistSD, MehtaID, MoskowitzWB: Congenital complete heart block: fetal management protocol, review of the literature, and report of the smallest successful pacemaker implantation.J. Perinatol., 24(2), 112–117 (2004).
  • Breur JM et al. , Udink Ten Cate FE, Kapusta L : Pacemaker therapy in isolated congenital complete atrioventricular block. Pacing Clin. Electrophysiol., 25(12), 1685–1691 (2002).
  • Kim JJ , FriedmanRA, EidemBWet al.: Ventricular function and long-term pacing in children with congenital complete atrioventricular block. J. Cardiovasc. Electrophysiol., 18(4), 373–377 (2007).
  • Hunt SA : ACC/AHA 2005 guideline update for the diagnosis and management of chronic heart failure in the adult: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Update the 2001 Guidelines for the Evaluation and Management of Heart Failure).J. Am. Coll. Cardiol., 46(6), e1–e82 (2005).
  • Strieper M , KarpawichP, FriasPet al.: Initial experience with cardiac resynchronization therapy for ventricular dysfunction in young patients with surgically operated congenital heart disease. Am. J. Cardiol., 94(10), 1352–1354 (2004).
  • Dubin AM , JanousekJ, RheeEet al.: Resynchronization therapy in pediatric and congenital heart disease patients: an international multicenter study. J. Am. Coll. Cardiol., 46(12), 2277–2283 (2005).
  • Silka MJ , HardyBG, MenasheVD, Morris CD:A population-based prospective evaluation of risk of sudden cardiac death after operation for common congenital heart defects. J. Am. Coll. Cardiol., 32(1), 245–251 (1998).
  • Etheridge SP , SanataniS, CohenMIet al.: Long QT syndrome in children in the era of implantable defibrillators. J. Am. Coll. Cardiol., 50(14), 1335–1340 (2007).
  • Dubin AM , BerulCI, BevilacquaLMet al.: The use of implantable cardioverter-defibrillators in pediatric patients awaiting heart transplantation. J. Card. Fail., 9(5), 375–379 (2003).
  • Eicken A , KolbC, LangeSet al.: Implantable cardioverter defibrillator (ICD) in children. Int. J. Cardiol., 107(1), 30–35 (2006).
  • DeMaso DR , LaurettiA, SpiethLet al.: Psychosocial factors and quality of life in children and adolescents with implantable cardioverter-defibrillators. Am. J. Cardiol., 93(5), 582–587 (2004).
  • Alexander ME , CecchinF, WalshEPet al.: Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics. J. Cardiovasc. Electrophysiol., 15(1), 72–76 (2004).
  • Korte T , KoditzH, NiehausM, PaulT, TebbenjohannsJ: High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator.Pacing Clin. Electrophysiol., 27(7), 924–932 (2004).
  • Celiker A , BaspinarO, KaragozT: Transvenous cardiac pacing in children: problems and complications during follow-up.Anadolu Kardiyol Derg, 7(3), 292–297 (2007).
  • Berul CI , VillafaneJ, AtkinsDLet al.: Pacemaker lead prolapse through the pulmonary valve in children. Pacing Clin. Electrophysiol., 30(10), 1183–1189 (2007).
  • Silvetti MS , DragoFet al., De Santis A : Single-centre experience on endocardial and epicardial pacemaker system function in neonates and infants. Europace, 9(6), 426–431 (2007).
  • Kammeraad JA , RosenthalE, BostockJ, RogersJ, SreeramN: Endocardial pacemaker implantation in infants weighing < or = 10 kilograms.Pacing Clin. Electrophysiol., 27(11), 1466–1474 (2004).
  • Figa FH , McCrindleBW, BigrasJL, HamiltonRM, GowRM: Risk factors for venous obstruction in children with transvenous pacing leads.Pacing Clin. Electrophysiol., 20(8 Pt 1), 1902–1909 (1997).
  • Bar-Cohen Y , BerulCI, AlexanderMEet al.: Age, size, and lead factors alone do not predict venous obstruction in children and young adults with transvenous lead systems. J. Cardiovasc. Electrophysiol., 17(7), 754–759 (2006).
  • Cannon BC , FriedmanRA, FenrichALet al.: Innovative techniques for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart. Pacing Clin. Electrophysiol., 29(2), 181–187 (2006).
  • Kriebel T , RuschewskiWet al., Gonzalez y Gonzalez M : ICD Implantation in infants and small children: the extracardiac technique. Pacing Clin. Electrophysiol., 29(12), 1319–1325 (2006).
  • Stephenson EA , BatraAS, KnilansTKet al.: A multicenter experience with novel implantable cardioverter defibrillator configurations in the pediatric and congenital heart disease population. J. Cardiovasc. Electrophysiol., 17(1), 41–46 (2006).
  • Bauersfeld U , TomaskeMet al., Dodge-Khatami A : Initial experience with implantable cardioverter defibrillator systems using epicardial and pleural electrodes in pediatric patients. Ann. Thorac. Surg., 84(1), 303–305 (2007).
  • Dodge-Khatami A , KadnerA, DaveHet al.: Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy in children: a safe approach with excellent functional and cosmetic results. Eur. J. Cardiothorac. Surg., 28(4), 541–545 (2005).
  • Ector B , WillemsR, HeidbuchelHet al.: Epicardial pacing: a single-centre study on 321 leads in 138 patients. Acta Cardiol., 61(3), 343–351 (2006).
  • Salerno JC , JohnstonTA, ChunTU, Jones TK: Coronary compression by an epicardial pacing lead within the pericardium. J. Cardiovasc. Electrophysiol., 18(7), 786 (2007).
  • Zeltser I , RhodesLA, TanelREet al.: Postpericardiotomy syndrome after permanent pacemaker implantation in children and young adults. Ann. Thorac. Surg., 78(5), 1684–1687 (2004).
  • Aellig NC , BalmerC, Dodge-KhatamiAet al.: Long-term follow-up after pacemaker implantation in neonates and infants. Ann. Thorac. Surg., 83(4), 1420–1423 (2007).
  • Cohen MI , RhodesLA, SprayTL, Gaynor JW: Efficacy of prophylactic epicardial pacing leads in children and young adults. Ann. Thorac. Surg., 78(1), 197–202; discussion 202–193 (2004).
  • Cohen MI , BushDM, VetterVLet al.: Permanent epicardial pacing in pediatric patients: seventeen years of experience and 1200 outpatient visits. Circulation, 103(21), 2585–2590 (2001).
  • Fortescue EB , BerulCI, CecchinFet al.: Comparison of modern steroid-eluting epicardial and thin transvenous pacemaker leads in pediatric and congenital heart disease patients. J. Interv. Card. Electrophysiol., 14(1), 27–36 (2005).
  • Murayama H , MaedaM, SakuraiH, Usui A, Ueda Y: Predictors affecting durability of epicardial pacemaker leads in pediatric patients. J. Thorac. Cardiovasc. Surg., 135(2), 361–366 (2008).
  • Thomson JD , BlackburnME, Van Doorn C, Nicholls A, Watterson KG: Pacing activity, patient and lead survival over 20 years of permanent epicardial pacing in children. Ann. Thorac. Surg., 77(4), 1366–1370 (2004).
  • Silvetti MS , DragoF, GrutterGet al.: Twenty years of paediatric cardiac pacing: 515 pacemakers and 480 leads implanted in 292 patients. Europace, 8(7), 530–536 (2006).
  • Fortescue EB , BerulCI, CecchinFet al.: Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease. Heart Rhythm, 1(2), 150–159 (2004).
  • Mathony U , SchmidtH, GrogerCet al.: Optimal maximum tracking rate of dual-chamber pacemakers required by children and young adults for a maximal cardiorespiratory performance. Pacing Clin. Electrophysiol., 28(5), 378–383 (2005).
  • Tomaske M , HarpesP, PretreR, Dodge-KhatamiA, BauersfeldU: Long-term experience with AutoCapture-controlled epicardial pacing in children.Europace, 9(8), 645–650 (2007).
  • Khairy P , LandzbergMJ, GatzoulisMAet al.: Transvenous pacing leads and systemic thromboemboli in patients with intracardiac shunts: a multicenter study. Circulation, 113(20), 2391–2397 (2006).
  • Shah MJ , NehgmeR, CarboniM, Murphy JD: Endocardial atrial pacing lead implantation and midterm follow-up in young patients with sinus node dysfunction after the fontan procedure. Pacing Clin. Electrophysiol., 27(7), 949–954 (2004).
  • Chintala K , ForbesTJ, KarpawichPP: Effectiveness of transvenous pacemaker leads placed through intravascular stents in patients with congenital heart disease.Am. J. Cardiol., 95(3), 424–427 (2005).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.