- Rengier F , MehndirattaA, von Tengg-KobligkHet al. 3D printing based on imaging data: review of medical applications. Int. J. Comput. Assist. Radiol. Surg.5(4), 335–341 (2010).
- Green DE , McNeeleyMF. Practice corner: a perfect fit. Radiographics32(7), 1975–1976 (2012).
- Tam MD , LaycockSD, BrownJR, JakewaysM. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy. J. Endovasc. Ther.20(6), 863–867 (2013).
- Itagaki MW . Using 3D printed models for planning and guidance during endovascular intervention: a technical advance. Diagn. Interv. Radiol.21(4), 338–341 (2015).
- Mitsouras D , LiacourasP, ImanzadehAet al. Medical 3D printing for the radiologist. Radiographics35(7), 1965–1988 (2015).
- Sheth R , BaleshER, ZhangYS, HirschJA, KhademhosseiniA, OkluR. Three-dimensional printing: an enabling technology for IR. J. Vasc. Interv. Radiol.27(6), 859–865 (2016).
- Mahesh M . Search for isotropic resolution in CT from conventional through multiple-row detector. Radiographics22(4), 949–962 (2002).
- Ionita CN , MokinM, VarbleNet al. Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing. Proc. SPIE Int. Soc. Opt. Eng.9038, 90380M (2014).
- Sherman J , RangwallaH, DohatcuA, MinsuokK, IonitaC, RudinS. SU-FF-I-127: patient specific angiography phantoms for investigating new endovascular image-guided interventional (EIGI) devices. Med. Phys.34(6), 2367 (2007).
- Sherman J , RangwalaH, IonitaCet al. Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging. Proc SPIE Int. Soc. Opt. Eng.6918, 69181v (2008).
- Schafer S , HoffmannKR, NoëlPB, IonitaCN, DmochowskiJ. Evaluation of guidewire path reproducibility. Med. Phys.35(5), 1884–1892 (2008).
- Ionita CN , SuriH, NataranjianSet al. Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study. Proc. SPIE Int. Soc. Opt. Eng.7965, 79651H1–79651H9 (2011).
- Meess KM , IzzoRL, DryjskiMLet al. 3D Printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system. Proc. SPIE Int. Soc. Opt. Eng.11, 10138 (2017).
- Cloonan AJ , ShahmirzadiD, LiRX, DoyleBJ, KonofagouEE, McGloughlinTM. 3D-printed tissue-mimicking phantoms for medical imaging and computational validation applications. 3D Print. Addit. Manuf.1, 14–23 (2014).
- de Galarreta SR , AitorC, AntónR, FinolEA. Abdominal aortic aneurysm: from clinical imaging to realistic replicas. J. Biomech. Eng.136, 014502 (2014).
- Biglino G , VerschuerenP, ZegelsR, TaylorAM, SchievanoS. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing. J. Cardiovasc. Magn. Reson.15, 2 (2013).
- Perrin D , BadelP, OrgeasLet al. Patient-specific simulation of endovascular repair surgery with tortuous aneurysms requiring flexible stent-grafts. J. Mech. Behav. Biomed. Mater.63, 86–99 (2016).
- Erbano BO , OpolskiAC, OlandoskiMet al. Rapid prototyping of three-dimensional biomodels as an adjuvant in the surgical planning for intracranial aneurysms. Acta. Cir. Bras.28(11), 756–761 (2013).
- Winder RJ , SunZ, KellyB, EllisPK, HirstD. Abdominal aortic aneurysm and stent graft phantom manufactured by medical rapid prototyping. J. Med. Eng. Technol.26(2), 75–78 (2002).
- Markl M , SchumacherR, KüfferJ, BleyTA, HennigJ. Rapid vessel prototyping: vascular modeling using 3t magnetic resonance angiography and rapid prototyping technology. MAGMA18(6), 288–292 (2005).