52
Views
0
CrossRef citations to date
0
Altmetric
Review

The Significance of Postprocedural Aortic Regurgitation After Transcatheter Aortic Valve Implantation On Postprocedural Prognosis

, &
Pages 637-645 | Published online: 07 Aug 2012

References

  • Iung B , BaronG, ButchartEGet al. A prospective survey of patients with valvular heart disease in Europe: the Euro Heart Survey on Valvular Heart Disease. Eur. Heart J. , 24(13), 1231–1243 (2003).
  • Dell‘Amore A , AquinoTM, PagliaroMet al. Aortic valve replacement with and without combined coronary bypass grafts in very elderly patients: early and long-term results. Eur. J. Cardiothorac. Surg. , 41(3), 491–498 (2012).
  • Bonow RO , CarabelloBA, KanuCet al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (writing committee to revise the 1998 guidelines for the management of patients with valvular heart disease): developed in collaboration with the Society of Cardiovascular Anesthesiologists: endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. Circulation , 114(5), E84–E231 (2006).
  • Leon MB , SmithCR, MackMet al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N. Engl. J. Med. , 363(17), 1597–1607 (2010).
  • Cribier A , EltchaninoffH, BashAet al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation , 106(24), 3006–3008 (2002).
  • Thomas M , SchymikG, WaltherTet al. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation , 122(1), 62–69 (2010).
  • Rodés-Cabau J , WebbJG, CheungAet al. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J. Am. Coll. Cardiol. , 55(11), 1080–1090 (2010).
  • Moat NE , LudmanPet al., de Belder MA Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) registry. J. Am. Coll. Cardiol., 58(20), 2130–2138 (2011).
  • Linke A . Treatment of high risk aortic stenosis patients with transcatheter medtronic corevalve implantation. Presented at: American College of Cardiology 2012. Chicago, IL, USA, 24–27 March 2012.
  • Smith CR , LeonMB, MackMJet al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N. Engl. J. Med. , 364(23), 2187–2198 (2011).
  • O‘Rourke DJ , PalacRT, MalenkaDJet al. Outcome of mild periprosthetic regurgitation detected by intraoperative transesophageal echocardiography. J. Am. Coll. Cardiol. , 38(1), 163–166 (2001).
  • Webb JG , AltweggL, BooneRHet al. Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes. Circulation , 119(23), 3009–3016 (2009).
  • Grube E , BuellesfeldL, MuellerRet al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve revalving system. Circ. Cardiovasc. Interv. , 1(3), 167–175 (2008).
  • Ewe SH , NgAC, SchuijfJDet al. Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation. Am. J. Cardiol. , 108(10), 1470–1477 (2011).
  • Gotzmann M , PljakicA, BojaraWet al. Transcatheter aortic valve implantation in patients with severe symptomatic aortic valve stenosis-predictors of mortality and poor treatment response. Am. Heart J. , 162(2), 238–245 (2011).
  • Jabbour A , IsmailTF, MoatNet al. Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J. Am. Coll. Cardiol. , 58(21), 2165–2173 (2011).
  • Colli A , D‘AmicoR, KempfertJet al. Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: impact of aortic cusp calcification on postoperative aortic regurgitation. J. Thorac. Cardiovasc. Surg. , 142(5), 1229–1235 (2011).
  • Al-Attar N , HimbertD, VahanianAet al. Severe intraprosthetic regurgitation by immobile leaflet after trans-catheter aortic valve implantation. Eur. J. Cardiothorac. Surg. , 39(4), 591–592 (2011).
  • Zegdi R , CiobotaruV, NoghinMet al. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. J. Am. Coll. Cardiol. , 51(5), 579–584 (2008).
  • Détaint D , LepageL, HimbertDet al. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. JACC Cardiovasc. Interv. , 2(9), 821–827 (2009).
  • Takagi K , LatibA, Al-LameeRet al. Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation. Catheter. Cardiovasc. Interv. , 78(3), 432–443 (2011).
  • Ussia GP , MulèM, TamburinoC. The valve-in-valve technique: transcatheter treatment of aortic bioprothesis malposition. Catheter. Cardiovasc. Interv., 73(5), 713–716 (2009).
  • Schultz C , PiazzaN, WeustinkAet al. How should I treat acute valve regurgitation? EuroIntervention , 7(1), 151–159 (2011).
  • Tops LF , WoodDA, DelgadoVet al. Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc. Imaging , 1(3), 321–330 (2008).
  • Ewe SH , NgAC, SchuijfJDet al. Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation. Am. J. Cardiol. , 108(10), 1470–1477 (2011).
  • Gonçalves A , AlmeriaC, Marcos-AlbercaPet al. Three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation. J. Am. Soc. Echocardiogr. , 25(1), 47–55 (2012).
  • Webb JG , PasupatiS, HumphriesKet al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation , 116(7), 755–763 (2007).
  • Ussia GP , BarbantiM, PetronioASet al. On behalf of the CoreValve Italian registry investigators. Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis. Eur. Heart J. , 33(8), 969–976 (2012).
  • Sellers RD , LevyMJ, AmplatzKet al. Left retrograde cardioangiography in acquired cardiac disease: technic, indications and interpretations in 700 cases. Am. J. Cardiol. , 14, 437–447 (1964).
  • Tribouilloy CM , Enriquez-SaranoM, FettSLet al. Application of the proximal flow convergence method to calculate the effective regurgitant orifice area in aortic regurgitation. J. Am. Coll. Cardiol. , 32(4), 1032–1039 (1998).
  • Enriquez-Sarano M , BaileyKR, SewardJBet al. Quantitative Doppler assessment of valvular regurgitation. Circulation , 87(3), 841–848 (1993).
  • Leon MB , PiazzaN, NikolskyEet al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic research consortium. J. Am. Coll. Cardiol. , 57(3), 253–269 (2011).
  • Zoghbi WA , ChambersJB, DumesnilJGet al. Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: a report from the American Society of Echocardiography‘s Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography. J. Am. Soc. Echocardiogr. , 22(9), 975–1014 (2009).
  • Sinning JM , HammerstinglC, Vasa-NicoteraMet al. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J. Am. Coll. Cardiol. , 59(13), 1134–1141 (2012).
  • Vahanian A , BaumgartnerH, BaxJet al. Guidelines on the management of valvular heart disease: the Task Force on the Management of Valvular Heart Disease of the European Society Of Cardiology. Eur. Heart J. , 28(2), 230–268 (2007).
  • Anderson RH , LalM, HoSY. Anatomy of the aortic root with particular emphasis on options for its surgical enlargement. J. Heart Valve Dis., 5(Suppl. 3), S249–S257 (1996).
  • Piazza N et al. , De Jaegere P, Schultz C Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ. Cardiovasc. Interv., 1, 74–81 (2008).
  • Tzikas A , SchultzCJ, PiazzaNet al. Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation. Catheter. Cardiovasc. Interv. , 77(6), 868–875 (2011).
  • Schultz CJ , MoelkerA, PiazzaNet al. Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer‘s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur. Heart J. , 31(7), 849–856 (2010).
  • Messika-Zeitoun D , SerfatyJM, BrochetEet al. Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J. Am. Coll. Cardiol. , 55, 186–194 (2010).
  • Leon MB . TAVR update 2011: the year in review. Presented at: Transcatheter Cardiovascular Therapeutics 2011. San Francisco, CA, USA, 7–11 November 2011.
  • John D , BuellesfeldL, YuecelSet al. Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc. Interv. , 3(2), 233–243 (2010).
  • Delgado V , NgACet al., van de Veire NR Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. Eur. Heart J., 31(9), 1114–1123 (2010).
  • Koos R , MahnkenAH, DohmenGet al. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int. J. Cardiol. , 150(2), 142–145 (2011).
  • Unbehaun A , PasicM, DreysseSet al. Transapical aortic valve implantation. J. Am. Coll. Cardiol. , 59(3), 211–221 (2012).
  • Sherif MA , Abdel-WahabM, StöckerBet al. Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the medtronic CoreValve bioprosthesis. J. Am. Coll. Cardiol. , 56(20), 1623–1629 (2010).
  • Edmunds LH et al. Jr, Clark RE, Cohn LH Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ad hoc liaison committee for standardizing definitions of prosthetic heart valve morbidity of the American Association For Thoracic Surgery and The Society Of Thoracic Surgeons. J. Thorac. Cardiovasc. Surg., 112(3), 708–711 (1996).
  • Rallidis LS , MoyssakisIE, IkonomidisIet al. Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up. Am. Heart J. , 138, 351–357 (1999).
  • Ionescu A , FraserAG, ButchartEG. Prevalence and clinical significance of incidental paraprostheticvalvar regurgitation: a prospective study using transoesophageal echocardiography. Heart, 89(11), 1316–1321 (2003).
  • Makkar RR . Two-year outcomes of transcatheter aortic valve replacement (TAVR) in ‘inoperable‘ patients with severe aortic stenosis: The Partner trial. Presented at: Transcatheter Cardiovascular Therapeutics 2011. San Francisco, CA, USA, 7–11 November 2011.
  • Abdel-Wahab M , ZahnR, HorackMet al. Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart , 97(11), 899–906 (2011).
  • Tamburino C , CapodannoD, RamondoAet al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation , 123(3), 299–308 (2011).
  • Makkar RR , FontanaGP, JilaihawiHet al. Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. N. Engl. J. Med. , 366(18), 1696–1704 (2012).
  • Kodali SK , WilliamsMR, SmithCRet al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N. Engl. J. Med. , 366(18), 1686–1695 (2012).
  • Frerker C , BergmannM, SchewelDet al. Successful reposition and treatment of severe aortic paraprosthetic regurgitation after percutaneous implantation of a self-expandable biological valve. J. Cardiovasc. Med. (Hagerstown) , 13(5), 346–350 (2012).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.