61
Views
4
CrossRef citations to date
0
Altmetric
Original

Rotation therapy with a cobalt60 unit

&
Pages 395-409 | Published online: 14 Dec 2010

References

  • Bullen, M. A. and Brunsden, B. S. (1957) A method for the remote measurement of liquid depth. Brit. J. Radiol, 30, p. 333.
  • Bullen, M. A. A low-frequency electro-mechanical integrator. Electronic Engng
  • Burlin, T. E. (1957) The evaluation of the dose to the thorax in rotational cobalt 60 therapy. Brit. J. Radiol, 30, p. 543.
  • Cohen, M. (1955) The unit of X-ray dose and its realisation. II. The patient and the roentgen. Brit. J. Radiol, 28, p. 669.
  • Dixon, W. R. , Garrett, C. and Morrison, A. (1952) Cobalt 60 teletherapy unit: output, depth dose and isodose distributions. National Research Council of Canada Report, 2667
  • Farmer, F. T. (1955) A sub-standard X-ray dosemeter. Brit. J. Radiol, 28, p. 304.
  • Fedoruk, S. O. and Johns, H. E. (1957) Transmission dose measurement for cobalt 60 radiation with special reference to rotation therapy. Brit. J. Radiol, 30, p. 190.
  • Green, D. T. and Errington, R. F. (1952) 1000 curie cobalt units for radiation therapy. 111 Design of a cobalt 60 beam therapy unit. Brit. J. Radiol, 25, p. 309.
  • Johns, H. E. (1953) The physics of radiation therapy, Charles, C. Thomas, Springfield
  • Johns, H. E. , Epp, E. R. , Cormack, D. V. and Fedoruk, S. O. (1952) Depth dose data and diaphragm design for the Saskatchewan 1000 curie cobalt unit. Brit. J. Radiol, 25, p. 302.
  • Johns, H. E. , Whitmore, G. F. , Watson, T. A. and Umberg, F. H. (1953) A system of dosimetry for rotation therapy with typical rotation distributions. J. Canad. Ass. Radiol, 4, p. 1.
  • Johns, H. E. , Morrison, M. T. and Whitmore, G. F. (1956) Dosage calculations for rotation therapy, with special reference to cobalt 60. Amer. J. Roentgenol, 75, p. 1105.
  • Jones, D. E. A. , Gregory, C. and Birchall, I. (1956) Dosage distribution in rotational cobalt 60 therapy. Brit. J. Radiol, 29, p. 196.
  • O'Connor, J. E. (1957) The variation of scattered X-rays with density in an irradiated body. Phys. Med. Biol, 1, p. 352.
  • Pfalzner, P. M. (1956) Rotation therapy with a cobalt 60 unit. II. Transit dose measurements as a means of correcting tumour dose for non-waterequivalent absorbing media. Acta radiol, 45, p. 62.
  • Pfalzner, P. M. and Inch, W. R. (1956) Rotation therapy with a cobalt 60 unit. I. Physical aspects of circumaxial rotation. Acta radiol, 45, p. 51.
  • Spiers, F. W. (1946) Effective atomic number and energy absorption in tissues. Brit. J. Radiol, 19, p. 52.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.