929
Views
37
CrossRef citations to date
0
Altmetric
RESEARCH ARTICLE

Evaluation of a patch antenna applicator for time reversal hyperthemia

, &
Pages 185-197 | Received 25 Mar 2008, Accepted 23 Oct 2009, Published online: 10 Feb 2010

References

  • Valdagni R, Amichetti M, Pani G. Radical radiation alone versus radical radiation plus microwave hyperthermia for N3 (TNM-UICC) neck nodes: A prospective randomized clinical trial. Int J Radiat Oncol Biol Phys 1988; 15(1)13–24
  • Valdagni R, Amichetti M. Report of long-term follow-up in a randomized trial comparing radiation therapy and radiation therapy plus hyperthermia to metastatic lymph nodes in stage IV head and neck patients. Int J Radiat Oncol Biol Phys 1993; 28: 163–169
  • Van der Zee J, Gonzáles Gonzáles D, Van Rhoon GC, van Dijk J, van Putten W, Hart A. Comparison of radiotherapy alone with radiotherapy plus hyperthermia in locally advanced pelvic tumours: A prospective, randomised, multicentre trial. Lancet 2000; 355: 1119–1125
  • Jones EL, Oleson JR, Prosnitz LR, Samulski TV, Vujaskovic Z, Yu D, Sanders LL, Dewhirst MW. Randomized trial of hyperthermia and radiation for superficial tumors. J Clin Oncol 2005; 23: 3079–3085
  • Issels RD, Lindner LH, Wust P, Hohenberger P, Jauch K, Daugaard S, Mansmann U, Hiddemann W, Blay J, Verweij J. Regional hyperthermia (RHT) improves response and survival when combined with systemic chemotherapy in the management of locally advanced, high grade soft tissue sarcomas (STS) of the extremities, the body wall and the abdomen: A phase III randomised pros. Clin. Oncol 2007 ASCO Annual Meeting Proceedings Part I., Vol 25, No. 18S(June 20 Supplement), Abs No. 10009
  • Trefná H, Vrba J, Persson M. Time-reversal focusing in microwave hyperthermia for deep seated tumours. 2009, Submitted to Phys Med Biol
  • Turner PF. Regional hyperthermia with an annular phased array. IEEE Trans Biomed Eng 1984; BME-31: 106–114
  • Cassereau D, Fink M. Time-reversal of ultrasonic fields-part III: Theory of the closed time-reversal cavity. IEEE Trans Ultrason Ferroelectr Freq Control 1992; 39(5)579–592
  • Paulides MM, Bakker JF, Chavannes M, van Rhoon GC. A patch antenna design for application in a phased-array head and neck hyperthermia applicator. IEEE Trans Biomed Eng 2007; 54: 2057–2063
  • Paulides MM, Bakker JF, Zwamborn APM, van Rhoon GC. A head and neck hyperthermia applicator: Theoretical antenna array design. Int J Hyperth 2007; 23: 59–67
  • Paulides MM, Bakker JF, van Rhoon GC. An electromagnetic head and neck hyperthermia applicator: Experimental phantom verification and FDTD model. Int J Radiat Oncol Biol Phys 2007; 68: 612–620
  • Paulides MM, Bakker JF, Neufeld E, Van der Zee J, Jansen PP, Levendag PC, van Rhoon GC. The HYPERcollar: A novel applicator for hyperthermia in the head and neck. Int J Hyperth 2007; 23: 567–576
  • Paulides MM, Wielheesen DHM, Van der Zee J, Van Rhoon GC. Assessment of the local SAR distortion by major anatomical structures in a cylindrical neck phantom. Int J Hyp 2005; 21: 125–140
  • International Telecommunication Union. Introduction to international radio regulations: Article 5. www.itu.int. (accessed 07122009)
  • Turner PF, Schaefermeyer T. BSD-2000 approach for deep local and regional hyperthermia: Clinical utility. Strahlenth Onkol 1989; 165: 700–704
  • Nadobny J, Wlodarczyk W, Westhoff L, Gellermann J, Rau B, Monich B, Wust P. Development and evaluation of a three-dimensional hyperthermia applicator with Water-Coated antennas (WACOA). Int J Hyp 2003; 30: 2052–2064
  • Wust P, Beck R, Fähling H, Seebass M, Wlodarczyk W, Hoffmann W, Nadobny J. Electric field distributions in a phased-array applicator with 12 channels: Measuring and numerical simulations. Med Phys 2000; 27: 2065–2579
  • Seebass M, Beck R, Gellermann J, Nadobny J, Wust P. Electromagnetic phased arrays for regional hyperthermia: Optimal frequency and antenna arrangement. Int J Hyperth 2001; 17: 321–336
  • Paulsen KD, Geimer S, Tang J, Boyse WE. Optimization of pelvic heating rate distributions with electromagnetic phased arrays. Int. J. Hyperth 1999; 15: 157–186
  • Crezee J, Kok HP, Wiersma J. Improving locoregional hyperthermia equipment using 3D power control: From AMC-4 to AMC-8.. 14–15, In Abstracts ESHO-05 2005
  • Kroeze H, Van de Kramer JB, De Leeuw AAC, Lagendijk JJW. Regional hyperthermia applicator design using FDTD modelling. Phys Med Biol 2001; 46: 1919–1935
  • Samulski TV, Fessenden P, Lee ER, Kapp DS, Tanabe E, McEuen A. Spiral microstrip hyperthermia applicators: Technical design and clinical performance. Int J Radiat Oncol Biol Phys 1990; 18: 233–242
  • Stauffer PR, Rossetto F, Leoncini M, Gentilli GB. Radiation patterns of dual concentric conductor microstrip antennas for superficial hyperthermia. IEEE Trans Biomed Eng 1998; 45: 605–613
  • Lepage AC, Begaud X. A compact ultrawide band triangular patch antenna. Microw Opt Technol Lett 2004; 40: 287–289
  • Jang Y-W. Experimental study of a broadband U-slot triangular patch antenna. Microw Opt Technol Lett 2002; 34: 325–327
  • Waterhouse R. Small microstrip patch antenna. Electronics Letters 1995; 31: 604–605
  • Sanad M. Effect of the shorting posts on short circuit microstrip antennas. In IEEE Ant Prop Symp 1994; 794–797
  • Guo YX, Luk MK, Lee KF. Dual-band slot-loaded short-circuited patch antenna. Electron Lett 2000; 36: 289–291
  • Li Y, Chair R, Luk MK, Lee KF. Broadband triangular patch antenna with folded shorting wall. IEEE Ant Wireless Prop Lett 2004; 3: 189–192
  • Row J-S, Liou Y-Y. Broadband short-circuited triangular patch antenna. IEEE Trans Ant Prop 2006; 54: 2137–2141
  • Liou Y-Y, Row J-S, Chen T-R. Dual-frequency design of a shorted triangular patch antenna. Microw Opt Technol Lett 2006; 48: 749–751
  • Wong KL, Pan M-C, Hsu W-H. Single-feed dual-frequency triangular microstrip antenna with a V-shaped slot. Microw Opt Technol Lett 1999; 20: 133–134
  • Lu J-H, Tang C-L, Wong K-L. Novel dual-frequency and broad-band designs of slot-loaded equilateral triangular microstrip antennas. IEEE Trans Ant Prop 2000; 48: 1048–1054
  • Hassani HR, Mirshekar-Syahkal D. Analysis of triangular patch antennas including radome effects. IEE Proceedings-H 1992; 139: 251–256
  • Nasimuddin, Esselle K, Verma AK. Resonance frequency of an equilateral triangular microstrip antenna. Microw Opt Technol Lett 2005; 47: 485–489
  • Lee K-F, Luk M-K, Dahele JS. Characteristic of the equilateral triangular patch antenna. IEEE Trans Ant Prop 1988; 36: 1510–1518
  • Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol 1996; 41: 2271–2293
  • Lazebnik M, Popovic D, McCartney L, Watkins CB, Lindstrom MJ, Harter J, Sewall S, Ogilvie T, Magliocco A, Breslin TM, et al. A large-scale study of the ultrawideband microwave dielectric properties of normal, benign, and malignant breast tissues obtained from cancer surgeries. Phys Med Biol 2007; 52: 6093–6115
  • CST Microwave studio, CST GmbH. Bad Nauheimer Str. 19, 64289 Darmstadt, http://www.cst.com (accessed 07122009).
  • Rossetto F, Stauffer PR, Manfrini V, Diederich CJ, Gentili GB. Effect of practical layered dielectric loads on SAR patterns from dual concentric conductor microstrip antennas. Int J Hyperthermia 1998; 14: 553–571

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.