References
- Dewhirst MW, Phillips TL, Samulski TV, Stauffer P, Shrivastava P, Paliwal B, et al. RTOG quality assurance guidelines for clinical trials using hyperthermia. Int J Radiat Oncol Biol Phys 1990;18:1249–59
- Emami B, Stauffer P, Prionas S, Ryan BS, Corry P, Dewhirst M, et al. RTOG quality assurance guidelines for interstitial hyperthermia. Int J Radiat Oncol Biol Phys 1991;20:1117–24
- Sapozink MD, Corry PM, Kapp DS, Myerson RJ. RTOG quality assurance guidelines for clinical trials using hyperthermia for deep-seated malignancy. Int J Radiat Oncol Biol Phys 1991;20:1109–15
- Waterman F, Dewhirst M, Fessenden P, Samulski T, Stauffer P, Emami B, et al. RTOG quality assurance guidelines for clinical trials using hyperthermia administered by ultrasound. Int J Radiat Oncol Biol Phys 1991;20:1099–107
- Hand JW, Langendijk JJW, Andersen JB, Bolomey JC. Quality assurance guidelines for ESHO protocols. Int J Hyperthermia 1989;5:421–8
- Hand JW. Biophysics and technology of electromagnetic hyperthermia. In: Gautherie M, editor. Methods of External Hyperthermia Heating. Berlin: Springer; 1990. pp 1–60
- Lagendijk JJW, Van Rhoon GC, Hornsleth SN, Wust P, De Leeuw ACC, Schneider CJ, et al. ESHO quality assurance guidelines for regional hyperthermia. Int J Hyperthermia 1998;14:125–33
- Van Rhoon GC, Van Der Heuvel DJ, Ameziane A, Rietveld PJ, Volenec K, Van Der Zee J. Characterization of the SAR-distribution of the Sigma-60 applicator for regional hyperthermia using a Schottky diode sheet. Int J Hyperthermia 2003;19:642–54
- Bruggmoser G, Bauchowitz S, Canters R, Crezee H, Ehmann M, Gellermann J, et al. Quality assurance for clinical studies in regional deep hyperthermia. Strahlenther Onkol 2011;187:605–10
- Harrison GH. Ultrasound hyperthermia applicators: Intensity distributions and quality assurance. Int J Hyperthermia 1990;6:169–74
- Hornsleth SN, Frydendal L, Mella O, Dahl O, Raskmark P. Quality assurance for radiofrequency regional hyperthermia. Int J Hyperthermia 1997;13:169–85
- Nussbaum G. Quality assessment and assurance in clinical hyperthermia: Requirements and procedures. Cancer Res 1984;44:S4811–17
- Schneider CJ, Van Dijk JDP, De Leeuw AAC, Wust P, Baumhoer W. Quality assurance in various radiative hyperthermia systems applying a phantom with LED matrix. Int J Hyperthermia 1994;10:733–47
- Shrivastava PN, Saylor TK, Matloubieh AY, Paliwal BR. Hyperthermia thermometry evaluation: Criteria and guidelines. Int J Radiat Oncol Biol Phys 1988;14:327–35
- Shrivastava PN, Saylor TK, Matloubieh AY, Paliwal BR. Hyperthermia quality assurance results. Int J Hyperthermia 1988;4:25–37
- Shrivastava P, Luk K, Oleson J, Dewhirst M, Pajak T, Paliwal BR, et al. Hyperthermia quality assurance guidelines. Int J Radiat Oncol Biol Phys 1989;16:571–87
- Shrivastava PN, Saylor TK. Physics evaluation and quality control of hyperthermia equipment. In: Gautherie M, editor. Methods of External Hyperthermic Heating. Berlin: Springer; 1990. pp 117–39
- Visser AG, van Rhoon GC. Technical and clinical quality assurance. In: Seegenschmiedt MH, Fessenden P, Vernon CC, editors. Thermoradiotherapy and Thermochemotherapy: Volume 1 Biology, Physiology, and Physics. Berlin: Springer; 1995. pp 453–72
- Kikuchi M, Amemiya Y, Egawa S, Onoyama Y, Kato H, Kanai H, et al. Guide to the use of hyperthermic equipment. 1. Capacitively-coupled heating. Int J Hyperthermia 1993;9:187–203
- Bruggmoser G. Some aspects of quality management in deep regional hyperthermia. Int J Hyperthermia 2012;28:562–9
- Cetas TC. Thermometry. In: Field SB, Hand JW, editors. An Introduction to the Practical Aspects of Clinical Hyperthermia. London: Taylor & Francis; 1990. pp 423–77
- Chakraborty DP, Brezovich IA. Error sources affecting thermocouple thermometry in RF electromagnetic fields. J Microw Power 1982;17:17–28
- Hoh LL, Waterman FM. Use of manganin-constantan thermocouples in thermometry units designed for copper-constantan thermocouples. Int J Hyperthermia 1995;11:131–8
- Waterman FM, Hoh LL. A recommended revision in the RTOG thermometry guidelines for hyperthermia administered by ultrasound. Int J Hyperthermia 1995;11:121–30
- Waterman FM. Invasive thermometry techniques. In: Seegenschmiedt MH, Fessenden P, Vernon CC, editors. Thermoradiotherapy and Thermochemotherapy: Volume 1, Biology, Physiology and Physics. Berlin: Springer; 1995. pp 331–60
- Wust P, Cho CH, Hildebrandt B, Gellermann J. Thermal monitoring: Invasive, minimal-invasive and non-invasive approaches. Int J Hyperthermia 2006;22:255–62
- Chan KW, Chou CK, McDougall JA, Luk KH. Changes in heating patterns due to perturbations by thermometer probes at 915 and 434 MHz. Int J Hyperthermia 1988;4:447–56
- Chan KW, Chou CK, McDougall JA, Luk KA. Perturbations due to the use of catheters with non-perturbing probes. Int J Hyperthermia 1988;4:699–702
- Chan KW, Chou CK. Use of thermocouples in the intense fields of ferromagnetic implant hyperthermia. Int J Hyperthermia 1993;9:831–48