26
Views
28
CrossRef citations to date
0
Altmetric
Original Article

Quality assurance in various radiative hyperthermia systems applying a phantom with LED matrix

, , , &
Pages 733-747 | Received 27 Jun 1993, Accepted 09 Nov 1993, Published online: 09 Jul 2009

References

  • Allen S., Kantor G., Bassen H., Ruggera P. CDRH RF phantom for hyperthermia systems evaluations. International Journal of Hyperthermia 1988; 4: 17–23
  • De Leeuw A. A. C., Lagendijk J. J. W. Design of a deep-body hyperthermia system based on the ‘Coaxial TEM’ applicator. International Journal of Hyperthermia 1987; 3: 413–421
  • De Leeuw A. A. C., Lagendijk J. J. W., Van den Berg P. M. SAR distribution of the ‘coaxial TEM’ system with variable aperture width: measurements and model computations. International Journal of Hyperthermia 1990; 6: 445–451
  • De Leeuw A. A. C., Mooibroek J., Lagendijk J. J. W. Specific absorption rate steering by patient positioning in the ‘Coaxial TEM’ system: phantom investigation. International Journal of Hyperthermia 1991a; 7: 605–611
  • De Leeuw A. A. C., Schneider C. J., Lagendijk J. J. W. Effect of the water bolus of the ‘Coaxial TEM’ hyperhermia system on SAR distributions. Strahlentherapie Onkogie 1991b; 167: 329
  • Dewhirst M. W., Phillips T. L. RTOG quality assurance guidelines for clinical trials using hyperthermia. International Journal Radiation Oncology, Biology and Physics 1990; 18: 1249–1259
  • Hand J. W., Lagendijk J. J. W., Bach Andersen J., Bolomey J. C. Quality assurance guidelines for ESHO protocols. International Journal of Hyperthermia 1989; 5(4)421–428
  • Lagendijk J. J. W., Molls M. Consensus on QA in deep body hyperthermia. Hyperthermia Bulletin of the COMAC-BME 1990; 5: 95–96
  • Leybovich L., Myerson R. J., Emami B., Straube W. L. Evaluation of the Sigma 60 applicator for regional hyperthermia in terms of scattering parameters. International Journal of Hyperthermia 1991; 7(6)917–935
  • Paulsen K. D., Ross M. P. Comparison of numerical calculations with phantom experiments and clinical measurements. International Journal of Hyperthermia 1990; 6: 333–349
  • Perez C. A., Emami B., Nussbaum G. H. Regional (deep) heating, clinical studies in progress. Frontiers in Radiation Oncology 1984; 18: 108–125
  • Perez C. A., Gillespie B., Pajak T., Hornback N. D., Emami B., Rubin P. Quality assurance problems in clinical hyperthermia and their impact on therapeutic outcome: a report by the radiation therapy aoncology group. International Journal Radiation Oncology, Biology and Physics 1989; 16: 551–558
  • Raskmark P., Larsen T., Hornsleth S. N. Analysis of multi-applicator systems using S-parameters. Hyperthermic Oncology 1992; 1: 242
  • Sathiaseelan V., Iskander M. F., Howard G. C. W., Bleehen N. M. Theoretical analysis and clinical demonstration of the effect of power pattern control using the Annular Phased-Array hyperthermia system. IEEE Transactions on Microwave Theory and Techniques 1986; 34: 514–519
  • Sathiaseelan V., Mittal B. B., Taflove A., Reuter C., Piket-May M. J., Pierce M. C. Strategies for improving sigma-60 deep hyperthermia applicator performance. Hyperthermic Oncology 1992; 1: 247
  • Schneider C. J., Van Dijk J. D. P. Visualization by a matrix of light emitting diodes of interferences effects from a radiative four-applicator hyperthermia system. International Journal of Hyperthermia 1991; 7: 355–366
  • Schneider C. J., De Leeuw A. A., Van Dijk J. D. P. Quantitative determination of SAR profiles from photographs of the LED matrix. International Journal of Hyperthermia 1992a; 8: 609–619
  • Scheider C. J., Van Dijk J. D. P., Sijbrands J., Van Os R., Van Stam G., Zum Vörde Sive Vörding P. J., Lamaitre G., Postma A., Koenis F. Visualization of interfering RF-electric fields in a lossy liquid simulating a patient's body in a hyperthermia treatment by a LED-matrix. IEEE-EMBS Conference, Paris, 1992b; 256–257
  • Shrivastava P. N., Saylor T. K., Matloubieh A. Y., Paliwal B. R. Hyperthermia quality assurance results. International Journal of Hyperthermia 1988; 4: 25–37
  • Shrivastava P. Hyperthermia quality assurance guidelines. International Journal of Radiation, Oncology and Biology Physics 1989; 16: 571–587
  • Stogryn A. Equations for calculating the dielectric constant of saline water. IEEE Transactions on Microwave Theory and Techniques 1971; 19: 733–736
  • Turner P. F. Regional hyperthermia with an annular phased array. IEEE Transactions on Biomedical Engineering 1984; BME-31: 106–114
  • Turner P. F., Schaefermeyer T. BSD-2000 approach for deep local and regional hyperthernmia: clinical utility. Strahlentherapie 1989; 165: 700–704
  • Van Dijk J. D. P., Gonzalez-Gonzalez D., Blank L. E. C.M. Deep local hyperthermia with a four aperture array system of large waveguide radiators. Results of simulation and clinical application. Hyperthermic Oncology 1988, T. Sugahara, M. Saito. Taylor & Francis, London 1989; 573–575
  • Van Dijk J. D. P., Schneider C. J., Van Os R. M., Blank L., Gonzalez-Gonzalez D. Results of deep body hyperthermia with large waveguide radiators. Consensus on Hyperthermia in the 1990's, H. I. Bicher. Plenum, New York 1990; 315–320
  • Wust P., Nadobny J., Felix R., Deuflhard P., Louis A., John W. Strategies for optimized application of annular-phased-array systems in clinical hyperthermia. International Journal of Hyperthermia 1991a; 7: 157–173
  • Wust P., Nadobny J., Fähling H., Riess H., Koch K., John W., Felix R. Einflussfaktoren und Störeffekte bei der Steuerung von Leistungsverteilungen mit dem Hyperthermie-Ringsystem BSD-2000. II. Messtechnische Analyse. Strahlenth. Onkol 1991b; 167: 172–180

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.