References
- Vogt A. Lehrbuch und Atlas der Spaltlampenmikroskopie des lebenden auges. Verlag von Julius Springer, Berlin 1930; 30–35
- Maurice D. M. A scanning slit optical microscope. Invest. Ophthalmol. 1974; 13: 1033–1037
- Laing R. A., Sandstrom M. M., Leibowitz H. M. In vivo photomicrography of the corneal endothelium. Arch. Ophthalmol. 1975; 93: 143–145
- Bourne W. M., Kaufman H. E. Specular microscopy of human corneal endothelium in vivo. Am. J. Ophthalmol. 1976; 81: 319–323
- Holm O. High magnification photography of the anterior segment of the human eye. Acta Ophthalmol. 1978; 56: 475–476
- Sturrock G. D., Sherrard E. S., Rue N. S.C. Specular microscopy of the corneal endothelium, Brit. J. Ophthalmol. 1978; 62: 809–814
- McCarey B. E. Non-contact specular microscopy. A macrophotography technique and some endothelial cell findings. Ophthalmology 1979; 86: 1848–1860
- Olsen T. Non-contact specular microscopy of human corneal endotheliumm. Acta Ophthalmol. 1997; 57: 986–998
- Koester C. J., Roberts C. W., Donn A., Hoefle F. B. Wide-field specular microscopy. Clinical and research applications. Ophthalmology 1980; 87: 849–860
- Lohman L. E., Rao G. N., Aquavella J. V. Optics and clinical applications of wide-field specular microscopy. Am. J. Ophthalmol. 1981; 92: 43–48
- Laing R. A., Sandstrom M. M., Berrospi A. R., Leibowitz H. M. Changes in the corneal endothelium as a function of age. Exp. Eye Res. 1976; 22: 587–594
- Laule A., Cable M. K., Hoffman C. E., Hanna C. Endothelial cell population changes of human cornea during life. Arch. Ophthalmol. 1978; 96: 2031–2035
- Suda T. Mosaic pattern changes in human corneal endothelium with age. Jpn. J. Ophthal. 1984; 28: 331–338
- Blackwell W. L., Gravenstein N., Kaufman H. E. Comparison of central corneal endothelial cell numbers with peripheral areas. Am. J. Ophthalmol. 1977; 84: 473–476
- Hoffer K. J. Vertical endothelial cell disparity. Am. J. Ophthalmol. 1979; 87: 344–349
- Shaw E. L., Rao G. N., Arthur E. J., Aquavella J. V. The functional reserve of corneal endothelium. Trans. Am. Acad. Ophthalmol. Otolaryngol. 1978; 85: 640–649
- Rao G. N., Shaw E. L., Arthur E. J., Aquavella J. V. Endothelial morphology and corneal deturgescense. Ann. Ophthal. 1978; 11: 885–899
- Rao G. N., Aquavella J. V., Goldberg S. H., Berk S. L. Pseudophakic bullous keratopathyi Relationship to preoperative corneal endothelial status. Ophthalmol. 1984; 91: 1135–1140
- Matsuda M., Suda T., Manabe R. Quantitative analysis of endothelial mosaic pattern changes in anterior keratoconus. Am. J. Ophthal. 1984; 98: 43–49
- Schultz R. O., Malsuda M., Yee R. W., Edelhauser H. F., Schultz K. J. Corneal endothelial changes in type I and type II diabetes mellitus. Am. J. Ophthal. 1984; 98: 401–410
- Holden B. A., Sweeney D. F., Vannas D., Nilsson K. T., Efron N. The effects of long-term extended wear of contact lenses on the human cornea. Invest. Ophthalmol. Vis. Sci. 1984; 25: 192, (suppl)
- Karaki T. Establishing a standard method of studying the corneal endothelium using a digitizer. Folia Ophthalmol. Jpn. 1981; 32: 2241–2247
- Inaba M., Matsuda M., Shiozaki Y., Kosaki H. Morphologic analysis of human corneal endothelium. Invest. Ophthalmol. Vis. Sci. 1984; 25: 240, (suppl)
- Waring G., III, Krohn M., Ford G., Harris R., Rosenblatt L. Four methods of measuring human corneal endothelial cells from specular photomicrographs. Arch. Ophthalmol. 1980; 98: 848–855
- Rao G., Waldron W., Aquavella J. Morphology of graft endothelium and donor age. Br. J. Ophthalmol. 1980; 64: 523–527
- Pardos G., Krachmer J. Comparison of endothelial cell density in diabetics and a control population. Am. J. Ophthalmol. 1980; 90: 172–174
- Sperling S. Early morphological changes in organ cultured human corneal endothelium. Acta Ophthalmol. 1978; 56: 785–792
- Sherrard E. S. The corneal endothelium in vivo: Its response to mild trauma. Exp. Eye Res. 1976; 22: 347–357
- Olsen T. Variations in endothelial morphology of normal corneas and after cataract extraction. A specular microscopic study. Acta Ophthalmol. 1979; 57: 1014–1019
- Honda H., Ogita Y., Higuchi S., Kani K. Cell movements in a living mammalian tissue: Long-term observations of individual cells in wounded endothelia of cats. J. Morphol. 1982; 174: 25–39
- Neubauer L., Baratz R. S., Laing R. A., Oak S. S., Leibowitz H. M. Coalescence of endothelial cells in the traumatized cornea: III. Correlation between specular and scanning electron microscopy. Arch. Ophthalmol. 1984; 102: 921–922
- Bourne W. M., Brubaker R. F., O'Fallon M. Use of air to decrease endothelial cell loss during intraocular lens implantation. Arch. Ophthalmol. 1979; 97: 1473–1475
- Thompson D. W. The forms of tissues on cell-aggregates. On Growth and Form, J. T. Bonner. University Press, Cambridge 1969; 88–119
- Rao G. N., Lohman L. E., Aquavella J. V. Cell-size-shape relationships in corneal endothelium. Invest. Ophthalmol. vis. Sci. 1982; 22: 271–174
- Honda H. Geometrical models for cells in tissues. Int. Rev. Cytol. 1983; 81: 191–248
- Tanimura K. A quantitative analysis of corneal endothelial cells. Folia Ophthalmol. Jpn. 1981; 32: 1835–1839
- Ehlers N. Graft thickness after penetrating keratoplasty. Acta Ophthalmol. 1974; 52: 893–903
- Bourne W. M. Morphologic and functional evaluation of the endothelium of transplanted human corneas. Trans. Am. Ophthalmol. Soc 1983; LXXXI: 403–450