893
Views
0
CrossRef citations to date
0
Altmetric
Review Article

Phase-contrast X-ray imaging of breast

, , , , &
Pages 866-884 | Accepted 15 Jun 2010, Published online: 30 Aug 2010

References

  • Elmore JG, Armstrong K, Lehman CD, Fletcher SW. Screening for breast cancer. JAMA 2005;293:1245–56.
  • Lord SJ, Lei W, Craft P, Cawson JN, Morris I, Walleser S, . A systematic review of the effectiveness of magnetic resonance imaging (MRI) as an addition to mammography and ultrasound in screening young women at high risk of breast cancer. Eur J Cancer 2007;43:1905–17.
  • Lehman CD, Isaacs C, Schnall MD, Pisano ED, Ascher SM, Weatherall PT, . Cancer yield of mammography, MR, and US in high-risk women: prospective multi-institution breast cancer screening study. Radiology 2007;244:381–8.
  • Durfee SM, Selland DL, Smith DN, Lester SC, Kaelin CM, Meyer JE. Sonographic evaluation of clinically palpable breast cancers invisible on mammography. Breast J 2000; 6:247–51.
  • Schulz-Wendtland R, Fuchsjäger M, Wacker T, Hermann KP. Digital mammography: an update. Eur J Radiol 2009;72: 258–65.
  • Haus AG, Yaffe MJ. Syllabus: a categorical course in physics. Technical aspects of breast imaging. Chicago: RSNA Publications; 1994. 95–7.
  • Pogany A, Gao D, Wilkins SW. Contrast and resolution in imaging with a microfocus x-ray source. Rev Sci Instrum 1997;68:2774–82.
  • Momose A, Takeda T, Itai Y, Yoneyama A, Hirano K. Perspective for medical applications of phase-contrast x-ray imaging. Ando M, Uyama C. Medical applications of synchrotron radiation. Tokyo: Springer-Verlag; 1998. 54–62.
  • Gabor D. A new microscopic principles. Nature 1948; 161:777–8.
  • Bonse U, Hart M. An x-ray interferometer. Appl Phys Lett 1965;6:155–6.
  • Förster E, Goetz K, Zaumseil P. Double crystal diffractometry for the characterization of targets for laser fusion experiments. Kristall und Technik 1980;15:937–45.
  • Podurets KM, Somenkov VA, Shil'shtein SSh. Refraction-contrast radiography. Sov Phys Tech Phys 1989;34:654–7.
  • Fernández M. X-ray scattering and diffraction enhanced imaging studies of in vitro breast tissues. Report series in physics. HU-P-D131 [dissertation]. Helsinki: University of Helsinki: Yliopistopaino; 2006. 1–53. Available from: http://urn.fi/URN:ISBN:952-10-2118–7.
  • Pucci-Minafra I, Albanese NN, Di Cara G, Minafra L, Marabeti MR, Cancemi P. Breast cancer cells exhibit selective modulation induced by different collagen substrates. Connect Tissue Res 2008;49:252–6.
  • Lewis RA, Rogers KD, Hall CJ, Towns-Andrews E, Slawson S, Evans A, . Breast cancer diagnosis using scattered x-rays. J Synchrotron Radiat 2000;7:348–52.
  • Fernández M, Keyriläinen J, Serimaa R, Torkkeli M, Karjalainen-Lindsberg ML, Tenhunen M, . Small-angle x-ray scattering studies of human breast tissue samples. Phys Med Biol 2002;47:577–92.
  • Fernández M, Keyriläinen J, Serimaa R, Torkkeli M, Karjalainen-Lindsberg ML, Leidenius M, . Human breast cancer in vitro: matching histo-pathology with small-angle x-ray scattering and diffraction enhanced x-ray imaging. Phys Med Biol 2005;50:2991–3006.
  • Fernández M, Suhonen H, Keyriläinen J, Bravin A, Fiedler S, Karjalainen-Lindsberg ML, . USAXS and SAXS from cancer-bearing breast tissue samples. Eur J Radiol 2008; 68:S89–S94.
  • Sidhu S, Siu KK, Falzon G, Nazaretian S, Harte SA, Fox JG, . X-ray scattering for classifying tissue types associated with breast disease. Med Phys 2008;35: 4660–70.
  • Sidhu S, Siu KK, Falzon G, Hart SA, Foxe JG, Lewis RA. Mapping structural changes in breast tissue disease using x-ray scattering. Med Phys 2009;36:3211–17.
  • Ando M, Bando H, Endo T, Ichihara S, Hashimoto E, Hyodo K, . Refraction-based 2D, 2.5D and 3D medical imaging: stepping forward to a clinical trial. Eur J Radiol 2008;68:S32–S36.
  • Pfeiffer F, Kottler C, Bunk O, David C. Hard x-ray phase tomography with low-brilliance sources. Phys Rev Lett 2007;98:108105–8.
  • Gureyev TE, Wilkins SW. Regimes of x-ray phase contrast imaging with perfect crystals. Il Nuovo Cimento 1997;19D:545–52.
  • Momose A, Takeda T, Itai Y, Hirano K. Phase-contrast x-ray computed tomography for observing biological soft tissues. Nat Med 1996;2:473–5.
  • Beckmann F, Bonse U, Busch F, Günnewig O. X-ray microtomography (microCT) using phase contrast for the investigation of organic matter. J Comput Assist Tomogr 1997;21:539–53.
  • Momose A, Fukuda J. Phase-contrast radiographs of nonstained rat cerebellar specimen. Med Phys 1995;22: 375–9.
  • Momose A, Takeda T, Itai Y. Phase-contrast x-ray computed tomography for observing biological specimens and organic materials. Rev Sci Instrum 1995;66:1434–6.
  • Momose A, Yoneyama A, Hirano K. Operation of a two-crystal x-ray interferometer at the photon factory. J Synchrotron Radiat 1997;4:311–12.
  • Takeda T, Momose A, Itai Y, Wu J, Hirano K. Phase-contrast imaging with synchrotron x-rays for detecting cancer lesions. Acad Radiol 1995;2:799–803.
  • Takeda T, Momose A, Hirano K, Haraoka S, Watanabe T, Itai Y. Human carcinoma: early experience with phase-contrast x-ray CT with synchrotron radiation – comparative specimen study with optical microscopy. Radiology 2000; 214:298–301.
  • Takeda T, Momose A, Wu J, Yu Q, Zeniya T, Thet-Thet-Lwin , . Vessel imaging by interferometric phase-contrast x-ray technique. Circulation 2002;105:1708–12.
  • Takeda T, Wu J, Tsuchiya Y, Yoneyama A, Lwin TT, Aiyoshi Y, . Interferometric x-ray imaging of breast cancer specimens at 51 keV x-ray energy. Jpn J Appl Phys 2004;43:5652–6.
  • Pfeiffer F, Weitkamp T, Bunk O, David C. Phase retrieval and differential phase-contrast imaging with low-brilliance x-ray sources. Nat Phys 2006;2:258–61.
  • Momose A, Kawamoto S, Koyama I, Hamaishi Y, Takai K, Suzuki Y. Demonstration of x-ray Talbot interferometry. Jpn J Appl Phys 2003;42: L866–8.
  • Weitkamp T, Diaz A, David C, Pfeiffer F, Stampanoni M, Cloetens P, . X-ray phase imaging with a grating interferometer. Opt Express 2005;13:6296–304.
  • Weitkamp T, David C, Bunk O, Bruder J, Cloetens P, Pfeiffer F. X-ray phase radiography and tomography of soft tissue using grating interferometry. Eur J Radiol 2008;68:S13–S17.
  • Arfelli F, Assante M, Bonvicini V, Bravin A, Cantatore G, Castelli E, . Low-dose phase contrast x-ray medical imaging. Phys Med Biol 1998;43:2845–52.
  • Snigirev A, Snigireva I, Kohn V, Kuznetsov S, Schelokov I. On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation. Rev Sci Instrum 1995;66:5486–92.
  • Wilkins SW, Gureyev TE, Gao D, Pogany A, Stevenson AW. Phase-contrast imaging using polychromatic hard x-rays. Nature 1996;384:335–8.
  • Cloetens P, Barrett R, Baruchel J, Guigay JP, Schlenker M. Phase objects in synchrotron radiation hard x-ray imaging. J Phys D Appl Phys 1996;29:133–46.
  • Nugent KA, Gureyev TE, Cookson DJ, Paganin D, Barnea Z. Quantitative phase imaging using hard x rays. Phys Rev Lett 1996;77:2961–4.
  • Raven C, Snigirev A, Snigireva I, Spanne P, Souvorov A, Kohn V. Phase-contrast microtomography with coherent high-energy synchrotron x-rays. Appl Phys Lett 1996;69:1826–8.
  • Kotre CJ, Birch IP. Phase contrast enhancement of x-ray mammography: a design study. Phys Med Biol 1999;44: 2853–66.
  • Freedman MT, Lo SCB, Honda C, Makariou E, Sisney G, Pien E, . Phase contrast digital mammography using molybdenum x-ray: clinical implications in detectability improvement. Yaffe MJ, Antonuk LE. Proceedings of the SPIE. Vol. 5030. USA: SPIE; 2003. 533.
  • Tanaka T, Honda C, Matsuo S, Noma K, Oohara H, Nitta N, . The first trial of phase contrast imaging for digital full-field mammography using a practical molybdenum x-ray tube. Invest Radiol 2005;40:385–96.
  • Honda C, Ohara H. Advantages of magnification in digital phase-contrast mammography using a practical x-ray tube. Eur J Radiol 2008;68:S69–S72.
  • Cloetens P, Ludwig W, Baruchel J, van Dyck D, van Landuyt J, Guigay J, . Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays. Appl Phys Lett 1999;75: 2912–14.
  • Dreossi D, Abrami A, Arfelli F, Bregant P, Casarin K, Chenda V, . The mammography project at the SYRMEP beamline. Eur J Radiol 2008;68:S58–S62.
  • Nesterets YI, Coan P, Gureyev TE, Bravin A, Cloetens P, Wilkins SW. On qualitative and quantitative analysis in analyser-based imaging. Acta Crystallogr A 2006;62: 296–308.
  • Pisano ED, Johnston RE, Chapman D, Geradts J, Iacocca MV, Livasy CA, . Human breast cancer specimens: diffraction-enhanced imaging with histologic correlation – improved conspicuity of lesion detail compared with digital radiography. Radiology 2000;214:895–901.
  • Keyriläinen J, Fernández M, Suortti P. Refraction contrast in x-ray imaging. Nucl Instrum Meth A 2002; 488:419–27.
  • Dilmanian FA, Zhong Z, Ren B, Wu XY, Chapman LD, Orion I, . Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method. Phys Med Biol 2000;45:933–46.
  • Davis TJ, Gao D, Gureyev TE, Stevenson AW, Wilkins SW. Phase-contrast imaging of weakly absorbing materials using hard x-rays. Nature 1995;373:595–8.
  • Ingal VN, Beliaevskaya EA. X-ray plane-wave topography observation of the phase contrast from a non-crystalline object. J Phys D Appl Phys 1995;28:2314–17.
  • Davis T. X-ray diffraction imaging using perfect crystals. J X-ray Sci Technol 1996;6:317–42.
  • Chapman D, Thomlinson W, Johnston RE, Washburn D, Pisano E, Gmür N, . Diffraction enhanced x-ray imaging. Phys Med Biol 1997;42:2015–25.
  • Oltulu O, Zhong Z, Hasnah M, Wernick MN, Chapman D. Extraction of extinction, refraction and absorption properties in diffraction enhanced imaging. J Phys D Appl Phys 2003;36:2152–6.
  • Pagot E, Cloetens P, Fiedler S, Bravin A, Coan P, Baruchel J, . A method to extract quantitative information in analyzer-based x-ray phase contrast imaging. Appl Phys Lett 2003;82:3421–3.
  • Rigon L, Besch HJ, Arfelli F, Menk RH, Heitner G, Plothow-Besch H. A new DEI algorithm capable of investigating sub-pixel structures. J Phys D Appl Phys 2003; 36:A107–12.
  • Rigon L, Arfelli F, Menk RH. Generalized diffraction enhanced imaging to retrieve absorption, refraction and scattering effects. J Phys D Appl Phys 2007;40:3077–89.
  • Wernick MN, Wirjadi O, Chapman D, Zhong Z, Galatsanos NP, Yang Y, . Multiple-image radiography. Phys Med Biol 2003;48:3875–95.
  • Bravin A. Exploiting the x-ray refraction contrast with an analyser: the state of the art. J Phys D Appl Phys 2003; 36:A24–9.
  • Khelashvili G, Brankov JG, Chapman D, Anastasio MA, Yang Y, Zhong Z, . A physical model of multiple-image radiography. Phys Med Biol 2006;51:221–36.
  • Chou CY, Anastasio MA, Brankov JG, Wernick MN, Brey EM, Connor DM, . An extended diffraction-enhanced imaging method for implementing multiple-image radiography. Phys Med Biol 2007;52:1923–45.
  • Suhonen H, Fernández M, Bravin A, Keyriläinen J, Suortti P. Refraction and scattering of x-rays in analyzer-based imaging. J Synchrotron Radiat 2007;14:512–21.
  • Keyriläinen J, Fernández M, Karjalainen-Lindsberg ML, Virkkunen P, Leidenius M, von Smitten K, . Toward high-contrast breast CT at low radiation dose. Radiology 2008;249:321–7.
  • Diemoz PC, Coan P, Glaser Ch, Bravin A. Absorption, refraction and scattering in analyzer-based imaging: comparison of different algorithms. Opt Express 2010; 18:3494–509.
  • Hu C, Zhang L, Li H, Lo S. Comparison of refraction information extraction methods in diffraction enhanced imaging. Opt Express 2008;16:16704–10.
  • Huang Z, Kang K, Yang Y. Extraction methods of phase information for x-ray diffraction enhanced imaging. Nucl Instrum Meth A 2007;579:218–22.
  • Bravin A, Mocella V, Coan P, Astolfo A, Ferrero C. A numerical wave-optical approach for the simulation of analyzer-based x-ray imaging. Opt Express 2007;15: 5641–8.
  • Castelli E, Arfelli F, Dreossi D, Longo R, Rokvic T, Cova MA, . Clinical mammography at the SYRMEP beam line. Nucl Instrum Meth A 2007;572:237–40.
  • Pagot E, Fiedler S, Cloetens P, Bravin A, Coan P, Fezzaa K, . Quantitative comparison between two phase contrast techniques: diffraction enhanced imaging and phase propagation imaging. Phys Med Biol 2005;50:709–24.
  • Olivo A, Rigon L, Vinnicombe SJ, Cheung KC, Ibison M, Speller RD. Phase contrast imaging of breast tumours with synchrotron radiation. Appl Radiat Isot 2009;67:1033–41.
  • Wu X, Liu H, Yan A. Phase-contrast x-ray tomography: contrast mechanism and roles of phase retrieval. Eur J Radiol 2008;68:S8–S12.
  • Johnston RE, Washburn D, Pisano E, Burns C, Thomlinson WC, Chapman LD, . Mammographic phantom studies with synchrotron radiation. Radiology 1996;200:659–63.
  • Thomlinson W, Chapman D, Zhong Z, Johnston RE, Sayers D. Ando M, Uyama C. Medical applications of synchrotron radiation. Tokyo: Springer-Verlag; 1998. 72–6.
  • Chapman D, Thomlinson W, Zhong Z, Johnston RE, Pisano E, Washburn D, . Diffraction enhanced imaging applied to materials science and medicine. Synchrotron Radiation News 1998;11:4–11.
  • Arfelli F, Bonvicini V, Bravin A, Cantatore G, Castelli E, Dalla Palma L, . Mammography with synchrotron radiation: phase-detection techniques. Radiology 2000;215: 286–93.
  • Ingal VN, Beliaevskaya EA, Brianskaya AP, Merkurieva RD. Phase mammography – a new technique for breast investigation. Phys Med Biol 1998;43:2555–67.
  • Faulconer L, Parham C, Connor DM, Zhong Z, Kim E, Zeng D, . Radiologist evaluation of an X-ray tube-based diffraction-enhanced imaging prototype using full-thickness breast specimens. Acad Radiol 2009;16:1329–37.
  • Suortti P, Thomlinson W. Medical applications of synchrotron radiation. Phys Med Biol 2003;48:R1–35.
  • Lewis RA. Medical phase contrast x-ray imaging: current status and future prospects. Phys Med Biol 2004;49: 3573–83.
  • Thomlinson W, Chapman LD, Schültke E, Juurlink BHJ, editors. Proceedings of the 5th medical application of synchrotron radiation 2007. Eur J Radiol 2008;68:S1–S162.
  • Fiedler S, Bravin A, Keyriläinen J, Fernández M, Suortti P, Thomlinson W, . Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology. Phys Med Biol 2004;49:175–88.
  • Keyriläinen J, Fernández M, Fiedler S, Bravin A, Karjalainen-Lindsberg ML, Virkkunen P, . Visualisation of calcifications and thin collagen strands in human breast tumour specimens by the diffraction-enhanced imaging technique: a comparison with conventional mammography and histology. Eur J Radiol 2005;53:226–37.
  • Bravin A, Keyriläinen J, Fernández M, Fiedler S, Nemoz C, Karjalainen-Lindsberg ML, . High-resolution CT by diffraction-enhanced x-ray imaging: mapping of breast tissue samples and comparison with their histo-pathology. Phys Med Biol 2007;52:2197–211.
  • Kao T, Connor D, Dilmanian FA, Faulconer L, Liu T, Parham C, . Characterization of diffraction-enhanced imaging contrast in breast cancer. Phys Med Biol 2009; 54:3247–56.
  • Dobbins JT 3rd, Godfrey DJ. Digital x-ray tomosynthesis: current state of the art and clinical potential. Phys Med Biol 2003;48:R65–106.
  • Kallergi M. Digital mammography: from theory to practice. Cancer Control 1998;5:72–9.
  • Bravin A, Fiedler S, Coan P, Labiche JC, Ponchut C, Peterzol A, . Comparison between a position sensitive germanium detector and a taper optics CCD “FRELON” camera for diffraction enhanced imaging. Nucl Instrum Meth A 2003;510:35–40.
  • Coan P, Peterzol A, Fiedler S, Ponchut C, Labiche JC, Bravin A. Evaluation of imaging performance of a taper optics CCD; ‘FReLoN’ camera designed for medical imaging. J Synchrotron Radiat 2006;13:260–70.
  • Boone JM, Kwan AL, Yang K, Burkett GW, Lindfors KK, Nelson TR. Computed tomography for imaging the breast. J Mammary Gland Biol Neoplasia 2006;11:103–11.
  • Lindfors KK, Boone JM, Nelson TR, Yang K, Kwan AL, Miller DF. Dedicated breast CT: initial clinical experience. Radiology 2008;246:725–33.
  • Glick SJ. Breast CT. Annu Rev Biomed Eng 2007;9: 501–26.
  • Karellas A, Vedantham S. Breast cancer imaging: a perspective for the next decade. Med Phys 2008;35: 4878–97.
  • Fernández M, Keyriläinen J, Karjalainen-Lindsberg ML, Leidenius M, von Smitten K, Fiedler S, . Human breast tissue characterisation with small-angle x-ray scattering. Spectroscopy 2004;18:167–76.
  • Pucci-Minafra I, Luparello C, Andriolo M, Basiricò L, Aquino A, Minafra S. A new form of tumor and fetal collagen that binds laminin. Biochemistry 1993;32: 7421–7.
  • American College of Radiology. Breast imaging reporting and data system (BI-RADS®). Breast imaging atlas. American College of Radiology (ACR). Reston: ACR; 2003.
  • Yamada H. Novel x-ray source based on a tabletop synchrotron and its unique features. Nucl Instrum Meth B 2003;199:509–16.
  • Hirai T, Yamada H, Sasaki M, Hasegawa D, Morita M, Oda Y, . Refraction contrast 11x-magnified x-ray imaging of large objects by MIRRORCLE-type table-top synchrotron. J Synchrotron Radiat 2006;13:397–402.
  • Pfeiffer F, Bech M, Bunk O, Kraft P, Eikenberry EF, Brönnimann Ch, . Hard x-ray dark-field imaging using a grating interferometer. Nat Mater 2008;7:134–7.
  • Coan P, Pagot E, Fiedler S, Cloetens P, Baruchel J, Bravin A. Phase-contrast X-ray imaging combining free space propagation and Bragg diffraction. J Synchrotron Radiat 2005; 12:241–5.
  • Coan P, Bravin A. Analysis of the x-ray refraction using an array-structured detector. Appl Phys Lett 2007;90:184106.
  • Carroll FE, Mendenhall MH, Traeger RH, Brau C, Waters JW. Pulsed tunable monochromatic x-ray beams from a compact source: new opportunities. Am J Roentgenol 2003; 181:1197–202.
  • Bech M, Bunk O, David C, Ruth R, Rifkin J, Loewen R, . Hard x-ray phase-contrast imaging with the Compact Light Source based on inverse Compton x-rays. J Synchrotron Radiat 2009;16:43–7.
  • Oliva P, Golosio B, Stumbo S, Bravin A, Tomassini P. Compact x-ray sources for mammographic applications: Monte Carlo simulations of image quality. Med Phys 2009;36:5149–61.
  • Keyriläinen J. Diffraction-enhanced x-ray imaging of in vitro breast tumours. Report series in physics. HU-P-D113 [dissertation]. Helsinki: University of Helsinki: Yliopistopaino; 2004. 1–99. Available from: http://urn.fi/URN:ISBN:952-10-1656-6.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.