References
- Blume H. Per technology, chapters 1–6, Philips Market Vision
- Foley W. D., Goodman L. R., Wilson C. R. The effect of varying pixel size and image processing on the detection of interstitial lung disease. Proceedings of the Chest Imaging Conference 1987. Medical Physics Publishing Co., MadisonUSA 1988
- Fraser R. G., Breatnach E., Barnes G. T. Digital radiography of the chest. Clinical experience with a prototype unit. Radiology 1983; 148: 1
- Goodman L. R., Foley W. D., Wilson C. R., Rimm A. A., Lawson T. L. Digital and conventional chest images. Observer performance with a film digital radiography system. Radiology 1986; 158: 27
- Goodman L. R., Foley W. D., Wilson C. R., Tikofsky R. S., Hoffman R. G. Pneumothorax and other lung diseases. Effect of altered resolution and edge enhancement on diagnosis with digitized radiographs. Radiology 1988; 176: 83
- Kehler M., Albrechtsson U., Andersson B., Lárusdóttir H., Lundin A., Pettersson H. Assessment of digital chest radiography using stimulable phosphor. Acta Radiol 1989; 30: 581
- Kehler M., Albrechtsson U., Andrésdóttir A., Lárusdóttir H., Lundin A. Accuracy of digital radiography using stimulable phosphor for diagnosis of pneumothorax. Acta Radiol 1990; 31: 47
- Kelsey C. A., Mettler F. A. Introduction to ROC analysis. Proceedings of the Chest Imaging Conference 1987. Medical Physics Publishing Co., MadisonUSA 1988
- Lams P. M., Cocklin M. L. Spatial resolution requirements for digital chest radiographs. ROC study of observer performance in selected studies. Radiology 1986; 158: 11
- MacMahon H., Vyborny C. J., Metz C. E., Doi K., Sabeti V., Solomon S. L. Digital radiography of subtle pulmonary abnormalities. An ROC study of the effect of pixel size on observer performance. Radiology 1986; 158: 21
- Merritt C. R. B., Matthews C. C., Sheinhorn D. S., Balter S. Digital imaging of the chest. J. Thorac. Imag 1985; 1: 1
- Metz C. E. Applications of ROC analysis in diagnostic image evaluation. The physics of medical imaging. Recording system measurements and technique, A. G. Haus. American Institute of Physics, New York 1979; 546
- Current problems in ROC analysis. Proceedings of the Chest Imaging Conference 1987. Medical Physics Publishing Co., MadisonUSA 1988
- Oestman J. W., Greene R., Rubens J. R., et al. High frequency edge enhancement in the detection of fine pulmonary lines. Parity between storage phosphor digital images and conventional chest radiology. Invest. Radiol 1989; 24: 643
- Seeley G. W., Fisher H. G., Stempski M. O., Borgstrom M., Bjelland J., Capp M. P. Total radiology department. Spatial resolution requirements. AJR 1987; 148: 421