References
- Moglia, A., Menciassi, A., Schurr, M.O.Dario, P., 2007, Wireless capsule endoscopy: from diagnostic devices to multipurpose robotic systems. Biomedical Microdevices, 9, 235–243.
- McCaffrey, C., Chevalerias, O., O’Mathuna, C.Twomey, K., 2008, Swallowable-capsule technology. IEEE Pervasive Computing, 7, 23–29.
- Swain, P., 2008, The future of wireless capsule endoscopy. World Journal of Gastroenterology, 14, 4142–4145.
- Carpi, F., 2010, Magnetic capsule endoscopy: the future is around the corner. Expert Review of Medical Devices, 7, 161–164.
- Eliakim, R., 2004, M2A capsule endoscopy—a painless voyage in the small bowel and beyond. Israel Medical Association Journal, 6, 560–561.
- Carta, R.Sfakiotakis, M.Pateromichelakis, N.Thone, J.Tsakiris, D.P.Puers, R., 2011, A multi-coil inductive powering system for an endoscopic capsule with vibratory actuation Sensors Actuators A. 172, 253–258.
- Van Gossum, A.Ibrahim, M., 2010, Video capsule endoscopy: what is the future? Gastroenterology Clinics of North America, 39, 807–826.
- International Commission on Non-ionizing Radiation Protection (ICNIRP), 1997, Guidelines for Limiting Exposure to Time-varying Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz) (Oberschleissheim: ICNRP).
- Japan Society of Medical Electronics and Biological Engineering, 2002, Basic Knowledge and Safety Management of Medical and Biological Engineering, 4th edn (Tokyo: Nankodo), pp. 42–60.
- Lee, S.W., Kim, J.D., Son, J.H., Ryu, M.H., and Kim, J.W., 2005, Design of two-dimensional coils for wireless power transmission to in vivo robotic capsule. 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1–7, 6631–6634.
- Lenaerts, B.Puers, R., 2005, Inductive powering of a freely moving system. Sensors and Actuators A, 123–124, 522–530.
- Miura, H., Arai, S., Kakubari, Y., Sato, F., Matsuki, H.Sato, T., 2006, Improvement of the transcutaneous energy transmission system utilizing ferrite cored coils for artificial hearts. IEEE Transactions on Magnetics, 42, 3578–3580.
- Lenaerts, B.Puers, R., 2007, An inductive power link for a wireless endoscope. Biosensors and Bioelectronics, 22, 1390–1395.
- Xin, W., Yan, G.Wang, W., 2010, Study of a wireless power transmission system for an active capsule endoscope. Medical Robotics in Computer-Integrated Surgery, 6, 113–122.
- Lenaerts, B.Puers, R., 2008, Automatic inductance compensation for class E driven flexible coils. Sensors and Actuators A, 145–146, 154–160.
- Ma, G., Yan, G.He, X., 2007, Power transmission for gastrointestinal microsystems using inductive coupling. Physiological Measurement, 28, 9–18.
- Carta, R., Thone, J.Puers, R., 2010, A wireless power supply system for robotic capsular endoscopes. Sensors and Actuators A, 162, 177–183.
- Jia, Zhiwei Yan, Guozheng Jiangpingping Wang, Zhiwu and Liu, Hua, 2011, Efficiency optimization of wireless power transmission systems for active capsule endoscopes. Physiol. Meas., 32, 1561–1573.
- Murray, J.M.Oleszek, G.M., 1979, Design considerations in class D MOS power amplifiers. IEEE Transactions on Industrial Electronics, IECI- 26(4), 211–218.
- Trout, S.R., 1988, Use of Helmholtz coils for magnetic measurements. IEEE Transactions on Magnetics, 24, 2108–2111.
- Ma, G.Y., 2008, Research on a miniature robot and wireless powering techniques for intestinal inspection. PhD Thesis, Shanghai Jiaotong University, China.