831
Views
14
CrossRef citations to date
0
Altmetric
Review Article

Upper limb functional electrical stimulation devices and their man–machine interfaces

, , &
Pages 471-479 | Received 01 Apr 2015, Accepted 22 Sep 2015, Published online: 28 Oct 2015

References

  • Kilgore, K.L., Hoyen, H.A., Bryden, A.M., Hart, R.L., Keith, M.W., and Peckham, P.H., 2008, An implanted upper-extremity neuroprosthesis using myoelectric control. The Journal Of Hand Surgery, 33, 539–550
  • Buckett, J.R., Peckham, P.H., Thrope, G.B., Braswell, S.D., and Keith, M.W., 1988, A flexible, portable system for neuromuscular stimulation in the paralyzed upper extremity. IEEE Transactions on Biomedical Engineering, 35, 897–904
  • Peckham, P.H., Keith, M.W., Kilgore, K.L., Grill, J.H., Wuolle, K.S, Thrope, G.B., Gorman, P., Hobby, J., Mulcahey, M.J., Carroll, S., Hentz, Vincent R., Wiegner, Allen et al. 2001, Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: A multicenter study. Archives of Physical Medicine and Rehabilitation, 82, 1380–1388
  • Taylor, P., Esnouf, J., and Hobby, J., 2002, The functional impact of the Freehand System on tetraplegic hand function. Clinical Results. Spinal Cord, 40, 560–566
  • Snoek, G.J., IJzerman, M.J., in‘t Groen, Fa.C.G., Stoffers, T.S., and Zilvold, G., 2000, Use of the NESS Handmaster to restore handfunction in tetraplegia: Clinical experiences in ten patients. Spinal Cord, 38, 244
  • Hendricks, H., IJzerman, M., de Kroon, J., Fac, and Zilvold, G., 2001, Functional electrical stimulation by means of the 'Ness Handmaster Orthosis' in chronic stroke patients: An exploratory study. Clinical Rehabilitation, 15, 217–220
  • Prochazka, A., Gauthier, M., Wieler, M., and Kenwell, Z., 1997, The bionic glove: An electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia. Archives Of Physical Medicine And Rehabilitation, 78, 608–614
  • Popović, D., Stojanović, A., Pjanović, A., Radosavljević, S., Popović, M., Jović, S., and Vulović, D., 1999, Clinical evaluation of the bionic glove. Archives of Physical Medicine and Rehabilitation, 80, 299–304
  • Kowalczewski, J., Chong, S.L., Galea, M., and Prochazka, A., 2011, In-home tele-rehabilitation improves tetraplegic hand function. Neurorehabil Neural Repair, 25, 412–422
  • Buick, A., Kowalczewski, J., Carson, R., and Prochazka, A., 2015, Tele-Supervised FES-Assisted Exercise for Hemiplegic Upper Limb. IEEE Transactions on Neural Systems & Rehabilitation Engineering, 11, 11
  • Popovic, D., and Popovic, M., 1998, Tuning of a nonanalytical hierarchical control system for reaching with FES. IEEE Transactions on Biomedical Engineering, 45, 203–212
  • Triolo, R., Nathan, R., Handa, Y., Keith, M., Betz, R.R., Carroll, S., and Kantor, C., 1996, Challenges to clinical deployment of upper limb neuroprostheses. Journal of Rehabilitation Research & Development, 33, 111–122
  • Shimada, Y., Sato, K., Kagaya, H., Konishi, N., Miyamoto, S., and Matsunaga, T., 1996, Clinical use of percutaneous intramuscular electrodes for functional electrical stimulation. Archives of Physical Medicine And Rehabilitation, 77, 1014–1018
  • Popovic, M.R., Popovic, D.B., and Keller, T., 2002, Neuroprostheses for grasping. Neurological Research, 24, 443–452
  • Keller, T., Popovic, M.R., Pappas, I.P.I., and Müller, P.-Y., 2002, Transcutaneous functional electrical stimulator “Compex Motion”. Artificial Organs, 26, 219–223
  • Mangold, S., Keller, T., Curt, A., and Dietz, V., 2005, Transcutaneous functional electrical stimulation for grasping in subjects with cervical spinal cord injury. Spinal Cord, 43, 1–13
  • Popovic, M.R., Thrasher, T.A., Adams, M.E., Takes, V., Zivanovic, V., and Tonack, M.I., 2005, Functional electrical therapy: retraining grasping in spinal cord injury. Spinal Cord, 44, 143–151
  • Popovic, M.R., Thrasher, T.A., Zivanovic, V., Takaki, J., and Hajek, V., 2005, Neuroprosthesis for retraining reaching and grasping functions in severe hemiplegic patients. Neuromodulation, 8, 58–72
  • Knutson, J.S., Chae, J., Hart, R.L., Keith, M.W., Hoyen, H.A., Harley, M.Y., Hisel, T.Z., Bryden, A.M., Kilgore, K.L., and Peckham, H., 2012, Implanted neuroprosthesis for assisting arm and hand function after stroke: a case study. Journal of Rehabilitation Research & Developent, 49, 1505–1516
  • Memberg, W.D., Polasek, K.H., Hart, R.L., Bryden, A.M., Kilgore, K.L., Nemunaitis, G.A., Hoyen, H.A., Keith, M.W., and Kirsch, R.F., 2014, Implanted neuroprosthesis for restoring arm and hand function in people with high level tetraplegia. Archives of Physical Medicine And Rehabilitation, 95, 1201–1211
  • Thorsen, R., Spadone, R., and Ferrarin, M., 2001, A pilot study of myoelectrically controlled FES of upper extremity. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 9, 161–168
  • Thorsen, R., Cortesi, M., Jonsdottir, J., Carpinella, I., Morelli, D., Casiraghi, A., Puglia, M., Diverio, M., and Ferrarin, M., 2013, Myoelectrically driven functional electrical stimulation may increase motor recovery of upper limb in poststroke subjects: A randomized controlled pilot study. Journal of Rehabilitation Research and Development, 50, 785–794
  • Thorsen, R.A., Occhi, E., Boccardi, S., and Ferrarin, M., 2006, Functional electrical stimulation reinforced tenodesis effect controlled by myoelectric activity from wrist extensors. Journal of Rehabilitation Research and Development, 43, 247–256
  • Thorsen, R., Dalla Costa, D., Chiaramonte, S., Binda, L., Beghi, E., Redaelli, T., Occhi, E., and Ferrarin, M., 2013, A noninvasive neuroprosthesis augments hand grasp force in individuals with cervical spinal cord injury: the functional and therapeutic effects. ScientificWorldJournal, 30, 785–794
  • Malesevic, N.M., Popovic Maneski, L.Z., Ilic, V., Jorgovanovic, N., Bijelic, G., Keller, T., and Popovic, D.B., 2012, A multi-pad electrode based functional electrical stimulation system for restoration of grasp. Journal of NeuroEngineering & Rehabilitation, 9, 1–13
  • Wheeler, C.A., and Peckham, P.H., 2009, Wireless wearable controller for upper-limb neuroprosthesis. Journal of Rehabilitation Research and Development, 46, 243–256
  • Mann, G., Taylor, P., and Lane, R., 2011, Accelerometer-triggered electrical stimulation for reach and grasp in chronic stroke patients: A pilot study. Neurorehabilitation and Neural Repair, 25, 774–780
  • Tong, K.Y., Mak, A.F.T., Ip, W.Y., 2002, Control for FES hand grasp systems using accelerometers and gyroscopes., Engineering in Medicine and Biology, 2002. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002. Proceedings of the Second Joint, 13, 2379–2381
  • Knutson, J.S., Hoyen, H.A., Kilgore, K.L., and Peckham, P.H., 2004, Simulated neuroprosthesis state activation and hand-position control using myoelectric signals from wrist muscles. Journal Of Rehabilitation Research And Development, 41, 461–472
  • Moss, C.W., Kilgore, K.L., and Peckham, P.H., 2011, Training to improve volitional muscle activity in clinically paralyzed muscles for neuroprosthesis control. Conference Proceedings IEEE Engineering in Medicine & Biology Society, 7, 5794–5797
  • Nathan, R.H., and Ohry, A., 1990, Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system. Archives Of Physical Medicine and Rehabilitation, 71, 415–421
  • Kapadia, N., Zivanovic, V., and Popovic, M.R., 2013, Restoring voluntary grasping function in individuals with incomplete chronic spinal cord injury: Pilot Study. Topics in Spinal Cord Injury Rehabilitation, 19, 279–287

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.