References
- Roy-Camille R, Saillant G, Bertreaux D. Early management of spinal injuries. In: McKibben B, editor. Recent Advances in Orthopedics. Edinburgh: Churchill-Livingstone; 1979. p. 57–87.
- Barrey C, Mertens P, Jund J, et al. Quantitative anatomic evaluation of cervical lateral mass fixation with a comparison of the Roy-Camille and the Magerl screw techniques. Spine. 2005;30:E140–E147.
- Heller JG, Estes BT, Zaouali M, et al. Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance. J Bone Joint Surg. 1996;78:1315–1321.
- Graham AW, Swank ML, Kinard RE, et al. Posterior cervical arthrodesis and stabilization with a lateral mass plate: Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications. Spine. 1996;21:323–328.
- Wellman BJ, Follett KA, Traynelis VC. Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients. Spine. 1998;23:193–200.
- Katonis P, Papadakis SA, Galanakos S, et al. Lateral mass screw complications: analysis of 1662 screws. J Spinal Disord Techniq 2011;24:415–420.
- Stemper BD, Marawar SV, Yoganandan N, et al. Quantitative anatomy of subaxial cervical lateral mass: An analysis of safe screw lengths for Roy-Camille and Magerl techniques. Spine. 2008;33:893–897.
- Harris BM, Hilibrand AS, Nien YH, et al. A comparison of three screw types for unicortical fixation in the lateral mass of the cervical spine. Spine. 2001;26:2427–2431.
- Seybold EA, Baker JA, Criscitiello AA, et al. Characteristics of unicortical and bicortical lateral mass screws in the cervical spine. Spine. 1991;24:2397–2403.
- Wu J, Huang W, Tsai H, et al. Pedicle screw loosening in dynamic stabilization: incidence, risk, and outcome in 126 patients. Neurosurg Focus. 2011;31:E9.
- Errico T, Uhl R, Cooper P, et al. Pullout strength comparison of two methods of orienting screw insertion in the lateral masses of the bovine cervical spine. J Spinal Disord. 1992;5:59–63.
- Ebraheim N. Posterior lateral mass screw fixation: anatomic and radiographic considerations. Univ Penn Orthopaed J. 1999;12:66–72.
- Esses SI, Sachs BL, Dreyzen V. Complications associated with the technique of pedicle screw fixation: a selected survey of ABS members. Spine. 1993;18:2231–2238.
- McKoy BE, An YH. An expandable anchor for fixation in osteoporotic bone. J Orthopaed Res. 2001;19:545–547.
- King TS, Cebon D. An alternative to screws for plating osteoporotic bone. J Biomed Eng. 1993;15:79–82.
- Zeiter S, Montavon P, Schneider E, et al. Plate stabilization with bone rivets: an alternative method for internal fixation of fractures. J Orthopaed Trauma. 2004;18:279–285.
- Zhang LC, Klemm D, Eckert J, et al. Manufacture by selective laser melting and mechanical behaviour of a biomedical Ti-24Nb-4Zr-8Sn alloy. Scripta Mater. 2011;65:21–24.
- Schatzker J. Screws and plates and their application. In: Muller ME, Allgöwer M, Schneider R, et al. editors. Manual of internal fixation: Techniques recommended by the AO-ASIF Group, 3rd edn. New York: Springer-Verlag; 1991. p. 179–199.
- Steeves M, Stone C, Mogaard J, et al. How pilot-hole size affects bone-screw pullout strength in human cadaveric cancellous bone. Can J Surg. 2005;48:207–212.
- Schindelin J, Arganda-Carreras I, Frise E, et al. Fiji: An open-source platform for biological-image analysis. Nature Meth. 2012;9:676–682.
- Doube M, Kłosowski MM, Arganda-Carreras I, et al. BoneJ: Free and extensible bone image analysis in ImageJ. Bone. 2010;47:1076–1079.
- Buie HR, Campbell GM, Klinck RJ, et al. Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. Bone. 2007;41:505–515.
- Wolff J. Das Gesetz der Transformation der Knochen. Berlin: Hirschwild; 1892.
- Seller K, Wahl D, Wild A, et al. Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies. Eur Spine J. 2007;16:1047–1054.
- Decoster TA, Heetderks DB, Downey DJ, Optimizing bone screw pullout force. J Orthopead Trauma. 1990;4:169–174.
- Wan S, Lei W, Wu Z, et al. Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep. Eur Spine J. 2010;19:2122–2129.
- Shi L, Wang L, Guo Z, et al. A study of low elastic modulus expandable pedicle screws in osteoporotic sheep. J Spinal Disord Techniq. 2012;25:123–128.
- Sanden B, Olerud C, Larsson S. Hydroxyapatite coating enhances fixation of loaded pedicle screws: a mechanical in vivo study in sheep. Eur Spine J. 2001;10:334–339.
- Liu D, Wu Z-X, Gao M-X, et al. A new method of partial screw augmentation in sheep vertebrae in vitro: Biomechanical and interfacial evaluation. J Spinal Disord Techniq. 2011;24:318–324.
- Wilke H-J, Daniel Z, Uwe W. Internal morphology of human facet joints: Comparing cervical and lumbar spine with regard to age, gender and the vertebral core. J Anat. 2012;220:233–241.
- Kandziora F, Pflugmacher R, Scholz M, et al. Comparison between sheep and human cervical spines: An anatomic, radiographic, bone mineral density, and biomechanical study. Spine. 2001;216:1028–1037.
- Öhman C, Dall’Ara E, Baleani M, et al. The effects of embalming using a 4% formalin solution on the compressive mechanical properties of human cortical bone. Clin Biomech. 2008;23:1294–1298.
- Borchers RE, Gibson LJ, Burchardt H, et al. Effects of selected thermal variables on the mechanical properties of trabecular bone. Biomaterials. 1995;16:545–551.