85
Views
12
CrossRef citations to date
0
Altmetric
Original Article

Enzyme electrodes as practical biosensors

Pages 293-298 | Published online: 09 Jul 2009

References

  • Guilbault G. G. Enzyme electrodes. Methods in Enzymology, S. P. Kolowick, N. O. Kaplan. Academic Press, New York 1976; 44: 579–618
  • Koryta J. Basic concepts of electroanalytical methods used in medicine and biology. Medical and Biological Applications of Electrochemical Devices, J. Koryta. Wiley-Interscience, New York 1980; 1–12
  • Clark L. C., Jr., Lyons C. Electrode systems for continuous monitoring in cardiovascular surgery. Annals New York Academy of Sciences 1962; 102: 29–45
  • Guilbault G. G. Enzyme electrode probes. Enzyme and Microbial Technology 1980; 2: 258–264
  • Covington A. K. Introduction: basic electrode types, classification, and selectivity considerations. Ion-Selective Electrode Methodology, A. K. Covington. CRC Press, Florida 1979; 1: 1–20
  • Fatt I. Polarographic Oxygen Sensors. CRC Press, Florida 1976
  • Ngo T. T. Bioanalytical applications of immobilised enzymes. International Journal of Biochemistry 1980; 11: 459–465
  • Bowers L. D., Carr P. W. Applications of immobilised enzymes in analytical chemistry. Analytical Chemistry 1976; 48: 545A–559A
  • Nilsson H., Akerlund A., Mosbach K. Determination of glucose, urea and penicillin using enzyme — pH electrodes. Biochimica Biophysica Acta 1973; 320: 529–534
  • Updike S. J., Hicks G. P. The enzyme electrode. Nature 1967; 214: 986–988
  • Bessman S. P., Schultz R. D. Progress towards a glucose sensor for the artificial pancreas. Advances in Medicine and Biology, H. J. Berman, N. C. Hebert. Plenum Press, New York 1974; 50: 189–197
  • Layne E. C., Schultz R. D., Thomas L. J., Slama G., Sayler B. S., Bessman S. P. Continuous extracorporeal monitoring of animal blood using the glucose electrode. Diabetes 1976; 25: 81–89
  • Romette J. L., Froment B., Thomas D. Glucose-oxidase electrode. Measurements of glucose in samples exhibiting high variability in oxygen content. Clinica Chimica Acta 1979; 95: 249–253
  • Sokol L., Garber C., Shults M., Updike S. Immobilised-enzyme rate-determination method for gbcose analysis. Clinical Chemistry 1980; 26: 89–92
  • Updike S. J., Shults M. C., Busby M. Continuous glucose monitor based on an immobilised enzyme electrode Setector. Journal of Laboratory and Clinical Medicine 1979; 93: 518–527
  • Williams D. L., Doig A. R., Korosi A. Electrochemical-enzymatic analysis of blood glucose and lactase. Analytical Chemistry 1970; 42: 118–121
  • Guilbault G. G., Lubrano G. J. An enzyme electrode for the amperometric determination of glucose. Analytica Chimica Acta 1977; 64: 439–455
  • Clark L. C., Jr., Clark E. W. Differential anodic enzyme polarography for the measurement of glucose. Advances in Experimental Medicine and Biology, D. F. Bruley, H. I. Bicher. Plenum Press, New York 1973; 37A: 127–156
  • Chua K. S., Tan I. K. Plasma glucose measurement with the Yellow Springs Glucose Analyser. Clinical Chemistry 1978; 24: 150–152
  • Keyes M. H., Semersky F. E., Gray D. N. Glucose analysis utilising immobilised enzymes. Enzyme and Mirobial Technology 1979; 1: 91–94
  • Grooms T. A., Clark L. C., Jr., Weiner B. J. The design of peroxide enzyme membrane polarographic sensors for clinical and industrial analysis. Enzyme Engineering, H. H. Weetall, G. P. Royer. Plenum Press, New York 1980; 5: 217–223
  • Fogt E. J., Lawrence M. D., Jenning M. E., Clemens A. H. Development and evaluation of a glucose analyser for a glucose-controlled insulin infusion system (Biostator®). Clinical Chemistry 1978; 24: 1366–1372
  • Clarke W. L., Santiago J. V. The characteristics of a new glucose sensor for use in an artificial pancreatic beta cell. Artificial Organs 1977; 2: 78–82
  • Silver I. A. An ultra micro glucose electrode. Ion and Enzyme Electrodes in Biology and Medicine, M. Kessler. University Park Press, Baltimore 1976; 189–192
  • Guilbault G. G., Hrabankova E. Determinations of urea in blood and urine with a urea-sensitive electrode. Analytica Chimica Acta 1970; 52: 287–294
  • Guilbault G. G., Nagy G., Kuan S. S. An improved electrode for the assay of urea in blood. Analytica Chimica Acta 1973; 67: 195–201
  • Mascini M., Guilbault G. G. Urease coupled ammonia electrode for urea determination in blood serum. Analytical Chemistry 1977; 49: 795–798
  • Ruzicka J., Hansen E. H. A new potentiometric gas sensor — the air-gap electrode. Analytica Chimica Acta. 1974; 69: 129–141
  • Guilbault G. G., Tarp M. A specific enzyme electrode for urea. Analytica Chimica Acta. 1974; 73: 355–365
  • Guilbault G. G., Stokbro W. The immobilised enzyme stirrer Part 1. A specific electrode for urea. Analytica Chimica Acta 1975; 76: 237–244
  • Guilbault G. G., Shu F. Enzyme electrodes based on the use of a carbon dioxide sensor. Urea and L-tyrosine electrodes. Analytical Chemistry 1972; 44: 2161–2166
  • Durliat H., Comtat, Baudras A. Spectrophotometric and electrochemical determinations of L(+)-lactate in blood by use of lactate dehydrogenase from yeast. Clinical Chemistry 1976; 22: 1802–1805
  • Soutter W. P., Sharp F., Clark D. M. Bedside estimation of whole blood lactate. British Journal of Anaesthesia 1978; 50: 445–450
  • Durliat H., Comtat M., Mahenc J. A device for the continuous assay of lactate. Analytica Chimica Acta 1979; 106: 131–135
  • Durliat H., Comtat M. Reagentless amperometric lactate electrode. Analytical Chemistry 1980; 52: 2109–2112
  • Clark L. C., Jr. A family of polarographic enzyme electrodes and the measurement of alcohol. Enzyme Engineering, L. B. Wingard, Jr. Wiley-Interxience, New York 1972; 377–394
  • Taylor P. J., Kmetec E., Johnson J. M. Design, construction, and applications of a galactose selective electrode. Analytical Chemistry 1977; 49: 789–794
  • Nanjo M., Guilbault G. G. Enzyme electrode sensing oxygen for uric acid in serum and urine. Analytical Chemistry 1974; 46: 1769–1772
  • Satoh I., Karube I., Suzuki S. Enzyme electrode for free cholesterol. Biotechnology and Bioengineering 1977; 19: 1095–1099
  • Bertrand C., Coulet P. R., Gautheron D. C. Enzyme electrode with collagen-irnmobilised cholesterol oxidase for the microdetermination of free cholesterol. Analytical Letters 1979; 12: 1477–1488
  • Meyerhoff M., Rechnitz G. A. An activated enzyme electrode for creatinine. Analytica Chimica Acta 1976; 85: 277–285
  • Pfeiffer D., Scheller F., Janchen M., Bertermann K. Glucose oxidase bienzyme electrodes for ATP, NAD+, Starch and disaccharides. Biochimie 1980; 62: 587–593
  • Rechnitz G. A., Kobos R. K., Riechel S. J., Gebauer C. R. A bio-selective membrane electrode prepared with living bacterial cells. Analytica Chimica Acta 1977; 94: 357–365
  • Arnold M. A., Rechnitz G. A. Determination of glutamine in cerebrospinal fluid with a tissue-based membrane electrode. Analytica Chimica Acta 1979; 113: 351–354
  • Chang K. W., Aisenberg S., Soeldner J. S., Hiebert J. M. Validation and bioengineering aspects of an implantable glucose sensor. Transactions of the American Society for Artificial Internal Organs 1973; 19: 352–360

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.