References
- Hurley AE. Use of KAFOs for patients with cerebral vascular accident, traumatic brain injury, and spinal cord injury. J Prosth Orth 2006;18(3):199–201.
- Zissimopoulos A, Fatone S, Gard SA. Biomechanical and energetic effects of a stance-control orthotic knee joint. J Rehabil Res Dev 2007;44(4):503–513.
- Lage KJ, White SC, Yack HJ. The effects of unilateral knee immobilization on lower extremity gait mechanics. Med Sci Sports Exercise 1995;27(1):8–14.
- Phillips B, Zhao H. Predictors of assistive technology abandonment. Assist Technol 1993;5:36–45.
- Kaplan LK, Grynbaum BB, Rusk HA, Anastasia T, Gassler S. A reappraisal of braces and other mechanical aids in patients with spinal cord dysfunction: Results of a follow-up study. Arch Phys Med Rehab 1996;47:393–405.
- Newell M. Stance control. Stance control. Alexandria, Virginia: AOPA; 2006.
- Irby SE, Bernhardt KA, Kaufman KR. Gait of stance control orthosis users: The dynamic knee brace system. Prosthet Orthot Int 2005;29(3):269–282.
- Irby SE, Bernhardt KA, Kaufman KR. Gait changes over time in stance control orthosis users. Prosthet Orthot Int 2007;31(4):353–361.
- McMillan AG, Kendrick K, Michael JW, Aronson J, Horton GW. Preliminary evidence for effectiveness of a stance control orthosis. J Prosth Orth 2004;16(1):6–13.
- Kaufman KR, Irby MS, Mathewson JW, Wirta RW, Sutherland DH. Energy-efficient knee-ankle foot orthosis: A case study. J Prosth Orth 1996;8(3):79–85.
- Hwang S, Kang S, Cho K, Kim Y. Biomechanical effect of electromechanical knee-ankle-foot-orthosis on knee joint control in patients with poliomyelitis. Med Biol Eng Comput 2008;46(6):541–549.
- Lehmann JF, Stonebridge JB. Knee lock device for knee ankle orthoses for spinal cord injured patients: An evaluation. Arch Phys Med Rehabil 1978;59(5):207–211.
- Bernhardt KA, Irby SE, Kaufman KR. Consumer opinions of a stance control knee orthosis. Prosthet Orthot Int 2006;30(3):246–256.
- Orendurff MS, Schoen JA, Bernatz GC, Segal AD, Klute GK. How humans walk: Bout duration, steps per bout, and rest duration. J Rehab Res Dev 2008;45(7):1077–1090.
- Mochon S, McMahon TA. Ballistic walking. J Biomech 1980;13(1):49–57.
- Murray MP, Sepic SB, Gardner GM, Mollinger LA. Gait patterns of above-knee amputees using constant-friction knee components. Bull Prosthet Res 1980l;10–34:35–45.
- Hebert JS, Liggins AB. Gait evaluation of an automatic stance-control knee orthosis in a patient with postpoliomyelitis. Arch Phys Med Rehabil 2005;86(8):1676–1680.
- Faul F, Erdfleder E, Lang A-G, Buchner A. G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Meth 2007;39(2):175–191.
- Traugh GH, Corcoran PJ, Reyes RL. Energy expenditure of ambulation in patients with above-knee amputations. Arch Phys Med Rehabil 1975;56(2):67–71.
- Isakov E, Susak Z, Becker E. Energy expenditure and cardiac response in above-knee amputees while using prostheses with open and locked knee mechanisms. Scand J Rehabil Med Suppl 1985;12:108–111.