References
- Karaaslan H, Peyronnet P, Benevent D, Lagarde C, Rince M, Leroux-Robert C. Risk of heparin lock-related bleeding when use indwelling venous catheter in hemodialysis. Nephrol Dial Transplant. 2001;16:2072–2074
- Sungur M, Eryuksel E, Yavas S, Bihorac A, Layon AJ, Caruso L. Exit of catheter lock solutions from double lumen acute hemodialysis catheters-an in vitro study. Nephrol Dial Transplant. 2007;22:3533–3537
- Agharazii M, Plamondon I, Lebel M, Douville P, Desmeules S. Estimation of heparin leak into the systemic circulation after central venous catheter heparin lock. Nephrol Dial Transplant. 2005;20:1238–1240
- Markota I, Markota D, Tomic M. Measuring of the heparin leakage into the circulation from central venous catheters-an in vivo study. Nephrol Dial Transplant. 2009;24:1550–1553
- Chen FK, Li JJ, Chen P, Zhao CZ, Gong HY, Yao DH. The effect of heparin saline used for catheter locking after heparin-free dialysis on coagulation parameters in patients with high bleeding risk. Chin J Blood Purif. 2012;11:245–248
- Yevzlin AS, Sanchez RJ, Hiatt JG, et al. Concentrated heparin lock is associated with major bleeding complications after tunneled hemodialysis catheter placement. Semin Dial. 2007;20:351–354
- National Institutes of Health NIDDK/DKUHD. USRDS 2010 Annual Data Report, volume two: atlas of End-Stage Renal Disease in the United States. 2010:270–284
- Moran JE, Ash SR; ASDIN Clinical Practice Committee. Locking solutions for hemodialysis catheters; heparin and citrate–a position paper by ASDIN. Semin Dial. 2008;21:490–492
- Twardowski ZJ, Reams G, Prowant BF, Moore HL, Van Stone JC. Air-bubble method of locking central-vein catheters for prevention of hub colonization: a pilot study. Hemodial Int. 2003;7:320–325
- Stas KJ, Vanwalleghem J, De Moor B, Keuleers H. Trisodium citrate 30% vs. heparin 5% as catheter lock in the interdialytic period in twin- or double-lumen dialysis catheters for intermittent hemodialysis. Nephrol Dial Transplant. 2001;6:1521–1522
- Weijmer MC, van den Dorpel MA, Van de Ven PJ, et al. Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients. J Am Soc Nephrol. 2005;16:2769–2777
- Venditto M, du Montcel ST, Robert J, et al. Effect of catheter-lock solutions on catheter-related infection and inflammatory syndrome in hemodialysis patients: heparin versus citrate 46% versus heparin/gentamicin. Blood Purif. 2010;29:268–273
- Winnett G, Nolan J, Miller M, Ashman N. Trisodium citrate 46.7% selectively and safely reduces staphylococcal catheter-related bacteraemia. Nephrol Dial Transplant. 2008;23:3592–3598
- Oguzhan N, Pala C, Sipahioglu MH, et al. Locking tunneled hemodialysis catheters with hypertonic saline (26% NaCl) and heparin to prevent catheter-related bloodstream infections and thrombosis: a randomized, prospective trial. Ren Fail. 2012;34:181–188