References
- Szivek J. A., Gealer R. G., Magee F. P., Emmanual J. Preliminary development of a hydroxyapatite-backed strain gauge. J Appl Biomater. 1990; 1: 241–248
- Maliniack M. M., Szivek J. A., De Young D. The development of hydroxyapatite coated strain gauges for long-term in vivo bone loading response measurements. J Appl Biomater. 1993; 4(2)143–152
- Szivek J. A., De Young D., Anderson PL. Evaluation of factors affecting bonding rate of calcium phosphate ceramic coatings for in vivo strain gauge attachment. J Biomed Mater Res. 1996; 33(3)121–132
- Szivek J. A., Johnson E. M., Magee FP. In vivo strain analysis of the greyhound femoral diaphysis. J Invest Surg. 1992; 5: 91–108
- Evans F. G. The mechanical properties of bone. Charles C. Thomas, Springfield, IL 1973
- Gies A. A., Carter DR. Experimental determination of whole long bone sectional properties. J Biomechanics 1982; 15: 297–303
- Pope M. H., Outwater JO. Mechanical properties of bone as a function of position and orientation. J Biomechanics 1974; 7: 61–66
- Kersey R. C., Szivek J. A., Sacoman DM. Symmetry of biome-chanical properties of canine femora. J Appl Biomater. 1994; 5(1)99–101
- Villanueva A. R. Histomorphometric quantitative analysis of bone. Theory and Practice of Histotechnology, DC Sheehan, B. Hrapchak. Mosby, St. Louis, MO 1980; 108–117
- Emmanual J., Hornbeck C., Bloebaum RD. A polymethyl-methacrylate method for large specimens of mineralized bone with implants. Stain Technol. 1987; 62: 401–410
- Villanueva A. R., Lundin KD. A versatile new mineralized bone strain for simultaneous assessment of tetracycline and osteoid seams. Stain Technol. 1989; 64: 129–138
- Skedros J. G., Bloebaum R. D., Bachus K. N., Boyce T. M. The meaning of gray levels in backscattered electron images of bone. J Biomed Mater Res. 1993; 27: 47–57
- Skedros J. G., Bloebaum R. D., Bachus K. N., Boyce T. M., Constance B. Influence of mineral content and composition on gray levels in backscattered electron images of bone. J Biomed Mater Res. 1993; 27: 57–65
- Baggot D. G., Lanyon LE. An independent “post-mortem” calibration of electrical resistance strain gauges bonded to bone surfaces “in vivo.”. J Biomechanics 1977; 10: 615–622
- Battraw G. A., Szivek J. A., Anderson P. L., Atcitty E. Interface strength studies of calcium phosphate ceramic-coated strain gauges. 23nd Annual Meeting of the Society of Biomaterials, New Orleans, LA, April, 1996
- Szivek J. A., Johnson E. M., Magee F. P., Emmanual J., Poser R. D., Koeneman JB. Bone remodeling andin vivo strain analysis of intact and implanted greyhound proximal femora. J Invest Surg. 1994; 7(3)213–233