Sample transport by pneumatic tube system alters results of multiple electrode aggregometry but not rotational thromboelastometry

, , , &
Pages 454-461 | Received 07 Jun 2012, Accepted 31 Jul 2012, Published online: 29 Aug 2012

References

  • Schochl H, Nienaber U, Maegele M, Hochleitner G, Primavesi F, Steitz B, Arndt C, Hanke A, Voelckel W, Solomon C. Transfusion in trauma: Thromboelastometry-guided coagulation factor concentrate-based therapy versus standard fresh frozen plasma-based therapy. Crit Care 2011; 15(2)R83
  • Tauber H, Innerhofer P, Breitkopf R, Westermann I, Beer R, El Attal R, Strasak A, Mittermayr M. Prevalence and impact of abnormal ROTEM(R) assays in severe blunt trauma: Results of the ‘diagnosis and treatment of trauma-induced coagulopathy (DIA-TRE-TIC) study’. Br J Anaesth 2011; 107(3)378–387
  • Schochl H, Nienaber U, Hofer G, Voelckel W, Jambor C, Scharbert G, Kozek-Langenecker S, Solomon C. Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate. Crit Care 2010; 14(2)R55
  • Stancheva A, Spassov L, Tzatchev K. Correlation between rotation thrombelastometry ROTEM analysis and standard haemostatic parameters during liver transplantation. Clin Lab 2011; 57(5–6)407–413
  • Roullet S, Pillot J, Freyburger G, Biais M, Quinart A, Rault A, Revel P, Sztark F. Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation. Br J Anaesth 2010; 104(4)422–428
  • Rahe-Meyer N, Solomon C, Winterhalter M, Piepenbrock S, Tanaka K, Haverich A, Pichlmaier M. Thromboelastometry-guided administration of fibrinogen concentrate for the treatment of excessive intraoperative bleeding in thoracoabdominal aortic aneurysm surgery. J Thorac Cardiovasc Surg 2009; 138(3)694–702
  • Rahe-Meyer N, Winterhalter M, Boden A, Froemke C, Piepenbrock S, Calatzis A, Solomon C. Platelet concentrates transfusion in cardiac surgery and platelet function assessment by multiple electrode aggregometry. Acta Anaesthesiol Scand 2009; 53(2)168–175
  • Valarche V, Desconclois C, Boutekedjiret T, Dreyfus M, Proulle V. Multiplate(R) whole blood impedance aggregometry: A new tool for von Willebrand disease. J Thromb Haemost 2011; 9(8)1645–1647
  • Steinlechner B, Dworschak M, Birkenberg B, Duris M, Zeidler P, Fischer H, Milosevic L, Wieselthaler G, Wolner E, Quehenberger P, et al. Platelet dysfunction in outpatients with left ventricular assist devices. Ann Thorac Surg 2009; 87(1)131–137
  • Solomon C, Traintinger S, Ziegler B, Hanke A, Rahe-Meyer N, Voelckel W, Schochl H. Platelet function following trauma. A multiple electrode aggregometry study. Thromb Haemost 2011; 106(2)322–330
  • Stissing T, Dridi NP, Ostrowski SR, Bochsen L, Johansson PI. The Influence of low platelet count on whole blood aggregometry assessed by Multiplate. Clin Appl Thromb Hemost 2011; 17(6)E211–E217
  • Canigral A, Silvestre FJ, Canigral G, Alos M, Garcia-Herraiz A, Plaza A. Evaluation of bleeding risk and measurement methods in dental patients. Med Oral Patol Oral Cir Bucal 2010; 15(6)e863–e868
  • Hanke AA, Roberg K, Monaca E, Sellmann T, Weber CF, Rahe-Meyer N, Gorlinger K. Impact of platelet count on results obtained from multiple electrode platelet aggregometry (Multiplate). Eur J Med Res 2010; 15(5)214–219
  • Weber CF, Gorlinger K, Byhahn C, Moritz A, Hanke AA, Zacharowski K, Meininger D. Tranexamic acid partially improves platelet function in patients treated with dual antiplatelet therapy. Eur J Anaesthesiol 2011; 28(1)57–62
  • Woo KS, Kim BR, Kim JE, Goh RY, Yu LH, Kim MH, Han JY. Determination of the prevalence of aspirin and clopidogrel resistances in patients with coronary artery disease by using various platelet-function tests. Korean J Lab Med 2010; 30(5)460–468
  • Velik-Salchner C, Maier S, Innerhofer P, Streif W, Klingler A, Kolbitsch C, Fries D. Point-of-care whole blood impedance aggregometry versus classical light transmission aggregometry for detecting aspirin and clopidogrel: The results of a pilot study. Anesth Analg 2008; 107(6)1798–1806
  • Rahe-Meyer N, Winterhalter M, Hartmann J, Pattison A, Hecker H, Calatzis A, Solomon C. An evaluation of cyclooxygenase-1 inhibition before coronary artery surgery: Aggregometry versus patient self-reporting. Anesth Analg 2008; 107(6)1791–1797
  • Mueller T, Dieplinger B, Poelz W, Haltmayer M. Utility of the PFA-100 instrument and the novel multiplate analyzer for the assessment of aspirin and clopidogrel effects on platelet function in patients with cardiovascular disease. Clin Appl Thromb Hemost 2009; 15(6)652–659
  • von Pape KW, Dzijan-Horn M, Bohner J, Spannagl M, Weisser H, Calatzis A. [Control of aspirin effect in chronic cardiovascular patients using two whole blood platelet function assays. PFA-100 and Multiplate]. Hamostaseologie 2007; 27(3)155–160
  • Hartert H. Blutgerinnungs studien mit der thrombelastographie, einem neuen untersuchungsverfahren. Klin Wochenschr 1948; 26(37–38)577–583
  • Spalding GJ, Hartrumpf M, Sierig T, Oesberg N, Kirschke CG, Albes JM. Cost reduction of perioperative coagulation management in cardiac surgery: Value of “bedside” thrombelastography (ROTEM). Eur J Cardiothorac Surg 2007; 31(6)1052–1057
  • Wallin O, Soderberg J, Grankvist K, Jonsson PA, Hultdin J. Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation. Clin Chem Lab Med 2008; 46(10)1443–1449
  • Kratz A, Salem RO, Van Cott EM. Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers. Arch Pathol Lab Med 2007; 131(2)293–296
  • Fernandes CM, Worster A, Eva K, Hill S, McCallum C. Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality. J Emerg Nurs 2006; 32(2)139–143
  • Bolliger D, Seeberger MD, Tanaka KA, Dell-Kuster S, Gregor M, Zenklusen U, Grapow M, Tsakiris DA, Filipovic M. Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry. Platelets 2009; 20(7)458–465
  • Dyszkiewicz-Korpanty A, Quinton R, Yassine J, Sarode R. The effect of a pneumatic tube transport system on PFA-100 trade mark closure time and whole blood platelet aggregation. J Thromb Haemost 2004; 2(2)354–356
  • Braun S, von Beckerath N, Ellert J, Kastrati A, Schomig A, Vogt W, Sibbing D. Assessment of platelet function in whole blood by multiple electrode aggregometry: Transport of samples using a pneumatic tube system. Am J Clin Pathol 2009; 132(5)802–803
  • Colucci G, Giabbani E, Barizzi G, Urwyler N, Alberio L. Laboratory-based ROTEM((R)) analysis: Implementing pneumatic tube transport and real-time graphic transmission. Int J Lab Hematol 2011; 33(4)441–446
  • Hübner U, Bockel-Frohnhofer N, Hummel B, Geisel J. The effect of a pneumatic tube transport system on platelet aggregation using optical aggregometry and the PFA-100. Clin Lab 2010; 56(1–2)59–64
  • Franz RC. ROTEM analysis: A significant advance in the field of rotational thrombelastography. S Afr J Surg 2009; 47(1)2–6
  • Hanke AA, Maschler S, Schochl H, Floricke F, Gorlinger K, Zanger K, Kienbaum P. In vitro impairment of whole blood coagulation and platelet function by hypertonic saline hydroxyethyl starch. Scand J Trauma Resusc Emerg Med 2011; 19: 12
  • Gorlinger K, Dirkmann D, Hanke AA, Kamler M, Kottenberg E, Thielmann M, Jakob H, Peters J. First-line therapy with coagulation factor concentrates combined with point-of-care coagulation testing is associated with decreased allogeneic blood transfusion in cardiovascular surgery: A retrospective, single-center cohort study. Anesthesiology 2011; 115(6)1179–1191
  • Gorlinger K. [Coagulation management during liver transplantation]. Hamostaseologie 2006; 26(3 Suppl 1)S64–S76
  • Spalding GJ, Hartrumpf M, Sierig T, Oesberg N, Kirschke CG, Albes JM. [Bedside thrombelastography. Cost reduction in cardiac surgery]. Anaesthesists 2007; 56(8)765–771
  • Lance MD, Henskens YM, Nelemans P, Theunissen MH, Oerle RV, Spronk HM, Marcus MA. Do blood collection methods influence whole-blood platelet function analysis?. Platelets May 30, 2012, [Epub ahead of print]
  • Kaiser AF, Neubauer H, Franken CC, Kruger JC, Mugge A, Meves SH. Which is the best anticoagulant for whole blood aggregometry platelet function testing? Comparison of six anticoagulants and diverse storage conditions. Platelets 2012; 23(5)359–367
  • Johnston LR, Larsen PD, La Flamme AC, Harding SA. Methodological considerations for the assessment of ADP induced platelet aggregation using the Multiplate(R) analyser. Platelets Jun 11, 2012, [Epub ahead of print]
  • Collinson PO, John CM, Gaze DC, Ferrigan LF, Cramp DG. Changes in blood gas samples produced by a pneumatic tube system. J Clin Pathol 2002; 55(2)105–107
  • Lang T, von Depka M. [Possibilities and limitations of thrombelastometry/-graphy]. Hamostaseologie 2006; 26(3 Suppl 1)S20–S29

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.