53
Views
30
CrossRef citations to date
0
Altmetric
Original Article

Applications of Artificial Cells in Medicine and Biotechnology

Pages 1-20 | Received 12 Sep 1986, Published online: 11 Jul 2009

References

  • Chang T MS. Hemoglobin corpuscles. Report of research project for Honours B.Sc. McGill University. 1957
  • Chang T MS. Semipermeable microcapsules. Science 1964; 14b: 524
  • Chang T MS, Macintosh F C, Mason S G. Semipermeable Microcapsules: I. Preparation and properties. Can J Physiol Pharmacol 1966; 44: 115–128
  • Chang T MS. Artificial Cells. Charles C Thomas Publisher, Springfield 1972; 111
  • Chang T MS. Nonthrombogenic Microcapsules. 3,522,346, (1970), US patent, Canadian Patent 876,100 (1971). Chang TMS, MacIntosh FC and Mason SG. Encapsulated hydrophilic compositions and methods of making them, Canadian Patent 873,815 (1971). Chang TMS. Blood compatible microcapsules containing detoxicants, US Patent 3,725,113 (1973); Canadian Patent 982,941 (1976). (All assigned to nonprofit organisations Research Co.)
  • Chang T MS. Microencapsulation and Artificial Cells. Humana Press, Clifton, NJ 1984
  • Chang T MS. Semipermeable aqueous microcapsules (“artificial cells”): with emphasis on experiments in an extracorporeal shunt system. Trans Amer Soc Artif Internal Organs 1966; 12: 13
  • Chang T MS. Removal of endogenous and exogenous toxins by a microencapsulated absorbent. Can J Physiol Pharmacol 1969; 47: 1043
  • Chang T MS, Malave N. The development and first clinical use of semiperemable microcapsules (artificial cells) as a compact artificial kidney. Trans Amer Soc Artif Internal Organs 1970; 16: 141
  • Chang T MS. Microcapsule artificial kidney: including updated preparative procedures and properties. Kidney Int 1976; 10: 218
  • Chang T MS. Artificial Kidney, Artificial Liver, and Artificial Cells. Plenum Press, New York 1978
  • Sideman S, Chang T MS. Hemoperfusion: Artificial Kidney and Liver Support and Detoxification, Part I. Hemisphere, Washington, DC 1980
  • Bonomini V, Chang T MS. Hemoperfusion, Contributions to Nephrology Series. S Karger AG, Basel 1982; 29
  • Klinkmann H, Falkenhagen D, Courtney J M. Blood purification by hemoperfusion. Int J Artif Organs 1979; 2: 296
  • Nikolaev V G, Strelko V V. Hemoperfusion. Naukova Dumka, Kiev 1979
  • Chang T MS, Gonda A, Dirks J H, Malave N. Clinical evaluation of chronic intermittent or short-term hemoperfusions in patients with chronic renal failure using semiperemable microcapsules (artificial cells) formed from membrane-coated activated charcoal. Trans Amer Soc Artif Internal Organs 1971; 17: 246
  • Chang T MS, Gonda A, Dirks J H, Coffey J F, Burns T. ACAC microcapsule artificial kidney for the long term and short term management of eleven patients with chronic renal failure. Trans Amer Soc Artif Internal Organs 1972; 18: 465–472
  • Chang T MS, Chirito E, Barre P, Cole C, Hewish M. Clinical performance characteristics of a new combined system for simultaneous hemoperfusion-hemodialysis-ultrafiltration in series. Trans Amer Soc Artif Internal Organs. 1975; 21: 502
  • Winchester J F, Apiliga M T, Mac Kay J M, Kennedy A C. Short term evaluation of charcoal hemoperfusion combined with dialysis in uremic patients. Kidney Int. 1976; 10: S315
  • Stefoni S, Coli L, Feliciangeli G, Baldrati L, Bonomini V. Regular hemoperfusion in regular dialysis treatment A long-term study. Int J Artif Organs. 1980; 3: 348
  • Chang T MS, Barre P, Kuruvilla S. Long-term reduced time hemoperfusion-hemodialysis compared to standard dialysis: A preliminary cross-over analysis. Trans Amer Soc Artif Intern Organs. 1985; 31: 572
  • Chang T MS, Chirito E, Barre P, Cole C, Lister C, Resurreccion E. Longterm clinical assessment of combined ACAC hemoperfusionultrafiltration in uremia. Artif Organs. 1979; 3: 127
  • Chang T MS, Barre P, Kuruvilla S, Messier D, Man M K, Resurreccion E. Phase 1 clinical trial of a new composite artificial kidney combining hemodialysis with hemoperfusion. Trans Amer Soc Artif Internal Organs. 1982; 28: 43
  • Chang T MS, Coffey J F, Barre P, Gouda A, Dirks J H, Levy M, Lister C. Microcapsule Artificial Kidney: treatment of patients with acute drug intoxication. Canadian Med Assoc J. 1973; 108: 429
  • Chang T MS, Coffey J F, Lister C, Taroy E, Stark A. Methaqualone, methyprylon, and glutethimide clearance by the ACAC microcapsule artificial kidney: in vitro and in patients with acute intoxication. Trans Amer Soc Artif Internal Organs. 1973; 19: 87
  • Vale J A, Rees A J, Widdop B, Goulding R. The use of charcoal hemoperfusion in the management of severely poisoned patients. British Med J. 1975; 1(5948)5
  • Poisoning and Drug Overdose, L M Haddad, J F Winchester. WB Saunders Co, Philadelphia 1983
  • Chang T MS, Espinosa-Melendez E, Francoeur T E, Eade N R. Albumincollodion activated coated charcoal hemoperfusion in the treatment of severe theophylline intoxication in a 3-year-old patient. Pediatrics. 1980; 65: 811
  • Chavers B M, Kjellstrand C M, Wiegand C, Ebben J, Mauer S M. Techniques for use of charcoal hemoeprfusion in infants. Kidney Int. 1980; 18: 386
  • Rosenbaum J L, Raja R. Hemoperfusion in acute intoxication. In Piskin The Past, Present and Future of Artificial Organs, E. TMS Chang. Meteksan Publisher, Ankara, Turkey 1982; 128
  • Chang T MS, Barre P. Effect of desferrioxamine on removal of aluminium and iron by coated charcoal haemoperfusion and haemodialysis. The Lancet. 1983; Nov: 1051
  • Chang T MS, Lister C, Varma R. Kinetics of coated charcoal hemoperfusion in the removal of Desferral. In Progress in Artificial Organs, K Atsumi, M Maekawa, K Ota. ISAO Press, Cleveland 1984; 602
  • Chang T MS. Haemoperfusion over microencapsulated adsorbent in a patient with hepatic coma. Lancet. 1972; ii: 1371–1372
  • Chang T MS, Migchelsen. Characterization of possible toxic metabolites in uremia and hepatic coma based on the clearance spectrum tor larger molecules by the ACAC microcapsule artificial kidney. Trans Am Soc Artif Intern Organs. 1973; 19: 314
  • Odaka M, Tabata Y, Kobayashi H, Nomura Y, Soma H, Hirasawa H, Sato H. Clinical experience of bead-shaped charcoal haemoperfusion in chronic renal failure and fulminant hepatic failure. In Artificial Kidney, Artificial Liver, and Artificial Cells, T MS Chang. Plenum Press, New York 1978
  • Agishi T, Yamashita N, Ota K. Clinical results of direct charcoal hemopertusion for endogenous and exogenous intoxication. In Hemoperfusion: Kidney and Liver Support and Detoxification, Part I, S Sideman, T MS Chang. Hemisphere, Washington 1980
  • Geltand M C, Winchester J F, Knepshield J H, Cohan S L, Schreiner G E. Biochemical correlates of reversal of hepatic coma with coated charcoal hemoperfusion. Trans Amer Soc Artif Intern Organs. 1978; 24: 239
  • Artificial Liver Support, K Williams, I M Murrary-Lyon. Pitman, London 1975
  • Chirito E, Keiter B, Lister C, Chang T MS. Artificial Liver: the effect of ACAC microencapsulated charcoal hemoperfusion on fulminant hepatic failure. Artif Organs 1977; 1(1)76
  • Chang T MS, Lister C, Chirito E, O'Keefe P, Resurreccion E. Effects of hemoperfusion rate and time of initiation of ACAC charcoal hemoperfusion on the survival of fulminant hepatic failure rats. Trans Amer Soc Artif Internal Organs. 1978; 24: 243
  • Tabata Y, Chang T MS. Comparisons of six artificial liver support regimes in fulminant hepatic coma rats. Trans Amer Soc Artif Internal Organs. 1980; 26: 394
  • Gimson A ES, Braude S, Mellon P J, Canalese J., Williams R. Earlier charcoal haemoperfusion in fulminant hepatic failure. Lancet. 1982; Sept. 25: 681
  • Shi Z Q, Chang T MS. Effects of hemoperfusion on blood and brain levels of tyrosine and middle molecules. Trans Amer Soc Artif Internal Organs. 1982; 28: 205
  • Chang T MS, Yu Y T, Grunwald J. Artificial cells immobilized multienzyme systems and cofactors. Enzyme Engineering. 1982; 16: 451
  • Chang T MS. Artificial cells with regenerating multienzyme systems methods in Enzymology. 1985; 112: 195
  • Gu K F, Chang T MS. Artificial cells with multienzyme systems for conversion of ammonia and urea into leucine, isoleucine and valine. J Biomat Artificial Cells and Artificial Organs 1987; 15, (this issue)
  • Bourget L, Chang T MS. Phenylaianine ammonia-lysase immobilized in semipermeable microcapsules for enzyme replacement in phenylketonuria. Fed of Europ Biochem Soc (FEBS Letters) 1985; 180: 5
  • Bourget L., Chang T MS. Phenylalanive ammonia lysase immobilised in semipermeable microcapsules for the depletion of phenylalanine in plasma in phenylketonuric rat model. Biochim Biophys Acta. 1986; 883: 432–438
  • Lemieux R U. Synthetic adsorbent for anti-A or anti-B antibodies. Chem Soc Rev. 1978; 7: 423
  • Chang T MS. Blood compatible coating of synthetic immunoadsorbents. Trans Amer Soc Artif Internal Organs. 1980; 26: 546
  • Bensinger W I, Bucker C D, Clift R A. Whole blood immunoadsorption of anti-A or anti-B antibodies. Vox Sang. 1985; 48: 357
  • Gardner D L, Falb R D, Kim B C, Emmerling D C. Possible uremic detoxification via oral ingested microcapsules. Trans Amer Soc Artif Intern Organs. 1971; 17: 239
  • Kjellstrand C, Borges H, Pur C, Gardner U, Fink U. Ureasezirconiumphosphate microcapsules (UZP) effectively decreases nitrogen accumulation in CRF patients. (Abstract) Am Soc Artif Intern Organs. 1981; 10: 47
  • Lim F, Sun A N. Microencapsulated islets as bioartificial endocrine pancreas. Science 1980; 210: 908
  • Damon Corporation. Tissue Microencapsulation. Needham Heights, Mass 1981
  • Wong H, Chang T MS. Bioartificial liver: artificial cells microencapsulated hepatocytes increases survival of liver failure rats. Int J Artit Organs. 1986; 9: 335
  • Chang T MS. Artificial red blood cells. Trans Amer Soc Artif Internal Organs. 1980; 2b: 354
  • Keipert P E, Minkowitz J, Chang T MS. Cross-linked stroma-free polyhemoglobin as a potential blood substitute. Int J Artif Organs. 1982; 5: 383
  • Benesch R, Benesch R E, Yung S, Edalji R. Hemoglobin covalently bridged across polyphosphate binding site. Biochem Biophs Res Commun. 1975; 63: 1123
  • Sehgal L K, Gould S A, Rosen A L, Sehgal H L, Moss G S. Polymerized pyridoxalated hemoglobin. Surgery. 1984; 95: 433
  • Bolin R B, Geyer R P, Nemo G J. Advances in Blood Substitute Research. A.R. Liss Inc, New York 1983
  • Keipert P E, Chang T MS. In vivo asessment of pyridoxylated cross-linked polyhemoglobin as an artificial red cell substitute in rats. Trans Amer Soc Artif Internal Organs. 1983; 29: 329
  • Chang T MS. The future potentials of blood substitutes in transfusion. Transplantation Today. 1985; Sept: 40
  • Keipert P E, Chang T MS. Pyridoxylated polyhemoglobin as a blood substitute for resuscitation of lethal hemorrhagic shock in conscious rats. Biomat, Med Dev, and Artif Organs. 1985; 13: 1
  • Geyer R P, Monroe R G, Taylor K. Survival of rats totally perfused with a fluorocarbon-detergent preparation. In: Organ Perfusion and Preservation, J C Norman, F Folkman. Appleton Century Crofts, New York 1968; 85
  • Abstracts IIIrd International Symposium on Blood Substitutes. J Biomaterial. Artificial Cells and Artificial Organs. 1987, (in press)
  • Proceeding, IIIrd International Symposium on Blood Substitutes (for), T MS Chang, R. Geyer. 1988

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.