2,369
Views
19
CrossRef citations to date
0
Altmetric
Research Article

Glucose biosensor based on the immobilization of glucose oxidase on electrochemically synthesized polypyrrole-poly(vinyl sulphonate) composite film by cross-linking with glutaraldehyde

, , &
Pages 354-361 | Received 23 Jan 2012, Accepted 19 Mar 2012, Published online: 30 Apr 2012

References

  • Adlan MA, Bondugulapati LN, Premawardhana LD. 2010. Glucose intolerance and diabetes mellitus in endocrine disorders – two case reports and a review. Curr Diabetes Rev. 6(5):266–73.
  • Aljane F, Toumi I, Ferchichi A. 2007. HPLC determination of sugars and atomic absorption analysis of mineral salts in fresh figs of Tunisian cultivars. African Journal of Biotechnology 6(5):599–602.
  • Arora K, Prabhakar N, Chand S, Malhotra BD. 2007. Immobilization of single stranded DNA probe onto polypyrrole-polyvinyl sulfonate for application to DNA hybridization biosensor. Sensors and Actuators B 126:655–663.
  • Arslan F, Ustabaş S, Arslan H. 2011. An amperometric biosensor for glucose determination prepared from glucose oxidase immobilized in polyaniline-polyvinylsulfonate film. Sensors 11: 8152–8163.
  • Arslan F, Yasar A, Kılıç E. 2006. An amperometric biosensor for xanthine determination prepared from xanthine oxidase immobilized in polypyrrole film. Artif. Cell Blood Subs. 34:1–16.
  • Bankar SB, Bule MV, Singhal RS, Ananthanarayan L. 2009. Glucose oxidase: An overview. Biotechnology Advances 27:489–501.
  • Çete S, Yaşar A, Arslan F. 2006. An amperometric biosensor for uric acid determination prepared from uricase immobilized in polypyrrole film. Artificial Cells, Blood Substitutes and Biotechnology 34:367–380.
  • Chaubey A, Gerard M, Singhal M, Singh VS, Malhotra BD. 2000. Immobilization of lactate dehydrogenase on electrochemically prepared polypyrrole–polyvinylsulphonate composite films for application to lactate biosensors. Electrochimica Acta. 46:723–729.
  • Collings AF, Caruso F. 1997. Biosensors: Recent advances. Reports on Progress in Physics 60:1397–1445.
  • Crouch E, Cowell DC, Hoskins S, Pittson RW, Hart JP. 2005. A novel, disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon ink. Biosensors and Bioelectronics 21:712–718.
  • Dohnal L, Kalousová M, Zima T. 2010. Comparison of three methods for determination of glucose. Prague Medical Report 111(1):42–54.
  • Gade VK, Shirale DJ, Gaikwad PD, Savale PA, Kakde KP, Kharat HJ, Shirsat MD. 2006. Immobilization of GOD on electrochemically synthesized Ppy–PVS composite film by cross-linking via glutaraldehyde for determination of glucose. Reactive & Functional Polymers 66:1420–1426.
  • Gade VK, Shirale DJ, Gaikwad PD, Savale PA, Kakde KP, Kharat HJ, Shirsat MD. 2007a. Immobilization of GOD on Ppy-PVS composite film for determination of glucose: A comparative study of phosphate and acetate buffers. International Journal of Polymeric Materials 56:1051–1065.
  • Gade VK, Shirale DJ, Gaikwad PD, Kakde KP, Savale PA, Kharat HJ, Shirsat MD. 2007b. Synthesis and characterization of Ppy-PVS, Ppy-pTS,and Ppy-DBS composite films. International Journal of Polymeric Materials 56:107–114.
  • Gade VK, Shirale DJ, Gaikwad PD, Kakde KP, Savale PA, Kharat HJ, Pawar BH, Shirsat MD. 2007c. Synthesis and characterization of Ppy-PVS, P(NMP)-PVS and their co-polymer Ppy-P(NMP)-PVS films by galvanostatic method. Int. J. Electrochem. Sci. 2:270–277.
  • Gerard M, Chaubey A, Malhotra BD. 2002. Application of conducting polymers to biosensors. Biosensors & Bioelectronics 17:345–359.
  • Gouda MD, Kumar MA, Thakur MS, Karanth NG. 2002. Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents. Biosensors and Bioelectronics 17:503–507.
  • Hendji AN, Bataillard P, Jaffrezic-Renault N. 1993. Covalent immobilization of glucose oxidase on silanized platinum microelectrode for the monitoring of glucose. Sens. Actuators B: Chem. 15:127–134.
  • Hodak J, Etchenique R, Calvo EJ, Singhal K, Bartlett PN. 1997. Layer-by-layer self-assembly of glucose oxidase with a poly(allylamine)ferrocene redox mediator. Langmuir 13:2708–2716.
  • Karyakin AA. 2001. Prussian blue based nano-electrode arrays for detection of H2O2 with advanced analytical performances. Electroanalysis 13:813–819.
  • Li J, Lin X. 2007. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode. Biosensors and Bioelectronics 22:2898–2905.
  • Malik B, Cote GL. 2010. Characterizing dual wavelength polarimetry through the eye for monitoring glucose. Biomedical Optics Express 1(5):1247–1258.
  • Newman JD, White SF, Tothill IE, Tumer APF. 1995. Catalytic materials, membranes, and fabrication technologies suitable for the construction of amperometric biosensors. Anal. Chem. 67:4594–4599.
  • Rahman MM, Ahammad AJS, Jin J-H, Ahn SJ, Lee J-J. 2010. A comprehensive review of glucose biosensors based on nanostructured metal-oxides. Sensors 10:4855–4886.
  • Rauf S, Ihsan A, Akhtar K, Ghauri MA, Rahman M, Anwar MA, Khalid AM. 2006. Glucose oxidase immobilization on a novel cellulose acetate–polymethylmethacrylate membrane. Journal of Biotechnology 121:351–360.
  • Retam RJ, Cabarcos EL, Mecerreyes D, Lopez-Ruiz B. 2004. Design of an amperometric biosensor using polypyrrole-microgel composites containing glucose oxidase. Biosensors and Bioelectronics 20:1111–1117.
  • Sesta G. 2006. Determination of sugars in royal jelly by HPLC. Apidologie 37:84–90.
  • Shankaran DR, Uehara N, Kato T. 2008. Metal dispersed sol-gel biocomposite amperometric glucose biosensor. Biosensors and Bioelectronics 18:721–728.
  • Shi R, Stein K, Schwedt G. 1997. Spectrophotometric determination of glucose in foods by flow injection analysis with an immobilized glucose oxidase reactor. Z Lebensm Unters Forsch A 204:99–102.
  • Singh S, Chaubey A, Malhotra BD. 2004. Preparation and characterization of an enzyme electrode based on cholesterol esterase and cholesterol oxidase immobilized onto conducting polypyrrole films. J. Appl. Polym. Sci. 91:3769–3773.
  • Singh M, Kathuroju PV, Jampana N. 2009. Polypyrrole based amperometric glucose biosensors. Sensors and Actuators B 143:430–443.
  • Singh S, Solanki KP, Pandey MK, Malhotra BD. 2006. Cholesterol biosensor based on cholesterol esterase, cholesterol oxidase and peroxidase immobilized onto conducting polyaniline films. Sensors and Actuators B 115:534–541.
  • Steegmans M, Iliaens S, Hoebregs H. 2004. Enzymatic, spectrophotometric determination of glucose, fructose, sucrose, and inulin/ oligofructose in foods. J AOAC Int. 87(5):1200–1207.
  • Sunil K, Arya AB, Arun K, Prusty SP, Singh A, Pratima R, Solanki KP, Manoj M, Malhotra BD. 2007. Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer. Analytical Biochemistry 363:210–218.
  • Tan X-C, Zhang J-L, Tan S-W, Zhao D-D, Huang Z-W, Mi Y, Huang Z-Y. 2009. Amperometric hydrogen peroxide biosensor based on immobilization of hemoglobin on a glassy carbon electrode modified with Fe3O4/chitosan core-shell microspheres. Sensors 9:6185–6199.
  • Vidal JC, Espuelas J, Garcia E, Castillo JR. 2004. Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers. Talanta 64:655–664.
  • Vidal JC, Garcia-Ruiz S, Mendez P, Castillo JR. 1999. Three approaches to the development of selective bilayer amperometric biosensors for glucose by in situ electropolymerization. Analyst 124:319–324.
  • Wan D, Yuan S, Li GL, Neoh KG, Kang ET. 2010. Glucose biosensor from covalent mmobilization of chitosan-coupled carbon nanotubes on polyaniline-modified gold electrode. Applied Materials & Interfaces 2(11):3083–3091.
  • Wang J. 2008. Electrochemical glucose biosensors. Chem. Rev. 2008108: 814–825.
  • Wang X, Zhang Y, Cheng C, Dong R, Hao J. 2011. Glucose in human serum determined by capillary electrophoresis with glucose micro-biosensor. Analyst. 136(8):1753–1759.
  • Wanga H, Ohnukia H, Endob H, Izumia M. 2011. Preparation of amperometric glucose biosensor based on 4-mercaptobenzoic acid. Physics Procedia 14:2–6.
  • Witt S, Wohlfahrt G, Schomburg D, Hecht H, Kalisz H. 2000. Conserved arginine-516 of Penicillium amagasakiense glucose oxidase is essential for the efficient binding of β-D-glucose. J. Biochem. 347:553–9.
  • Yıldırımoğlu F, Arslan F, Çete S, Yas ar A. 2009. Preparation of a polypyrrole polyvinylsulphonate composite film biosensor for determination of cholesterol based on entrapment of cholesterol oxidase. Sensors 9:6435–6445.
  • Yıldız HB, Kiralp S, Toppare L, Yagc Y. 2005. Immobilization of glucose oxidase in conducting graft copolymers and determination of glucose amount in orange juices with enzyme electrodes. International Journal of Biological Macromolecules 37:174–178.
  • Zhang Y, Guo G, Zhao F, Mo Z, Xiao F, Zeng B. 2010. A novel glucose biosensor based on glucose oxidase immobilized on AuPt nanoparticle-carbon nanotube-ionic liquid hybrid coated electrode. Electroanalysis 22:223–228.
  • Zhang Y, Wen G, Zhou Y, Shuang S, Dong C, Choi MM. 2007. Development and analytical application of an uric acid biosensor using an uricase-immobilized eggshell membrane. Biosens. Bioelectron. 22:1791–1797.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.