135
Views
6
CrossRef citations to date
0
Altmetric
Original Article

Improved Localization of Coronary Stents Using Layer Decomposition

, &
Pages 84-89 | Received 05 Mar 2001, Accepted 23 Mar 2002, Published online: 06 Jan 2010

References

  • Schuhlen H, Kastrati A, Dirschinger J, Hausleiter J, Elezi S, Wehinger A, Pache J, Hadamitzky M, Schomig A. Intracoronary stenting and risk for major adverse cardiac events during the first month. Circulation 1998; 98(2)104–111
  • De Scheerder I, Wang K, Zhou X R., Ping Q B., Yanming H, Jianhua H, Xiaoshun L, Szilard M, Verbeken E, Zhu X, van de Werf F. Overlapping coronary stents result in an increased neointimal hyperplasia response: insight from a porcine coronary stent model. J Am Coll Cardiol 1999; 33(2)31
  • Goldberg S L., Colombo A, Nakamura S, Almagor M, Maiello L, Tobis J M. Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents. J Am Coll Cardiol 1994; 24(4)996–1003
  • Nakamura S, Colombo A, Gaglione S, Almagor Y, Goldberg S L., Maiello L, Finci L, Tobis J M. Intracoronary. ultrasound observations during stent implantation. Circulation 1994; 89(5)2026–2034
  • Schomig A, Kastrati A, Pache J, Mehilli J, Schuhlen H, Ezezi S, Neumann F J. Randomized comparison of gold-plated steel stent with conventional steel stent: results of the angiographic follow-up. J Am Coll Cardiol 1999; 33(2)95
  • Close R A., Abbey C K., Whiting J S. (2000) Layer decomposition of coronary angiograms. Proceedings of SPIE 3979. 2000, K M. Hanson. SPIE, Bellingham, 1230–1234, Medical Imaging 2000: Image Processing
  • Close R A., Abbey C K., Whiting J S. (2000) Improved image guidance of coronary stent deployment. Proceedings of SPIE 3976. 2000, S K. Mun. SPIE, Bellingham, 301–305, Medical Imaging 2000: Image Display and Visualization
  • Close R A., Abbey C K., Morioka C A., Whiting J S. Accuracy assessment of layer decomposition using simulated angiographic image sequences. IEEE Trans Med Imag 2001; 20(10)990–998
  • Barten P GJ. The SQRI method: a new method for the evaluation of visible resolution on a display. Proc Soc Inf Disp 1987; 28: 253–262
  • Sheskin D J. Handbook of Parametric and Nonparametric Statistical Procedures. CRC Press, New York 1997; 303–314
  • Dumay A CM, Reiber J HC, Gerbrands J J. Determination of optimal angiographic viewing angles: basic principles and evaluation study. IEEE Trans Med Imag 1994; 13(1)13–24

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.