References
- Tile M. Fractures of the Pelvis and Acetabulum, 2nd edition. Williams and Wilkins, Baltimore 1995
- Tile M. Fractures of the acetabulum. Rockwood CA, Green DP, Bucholz RW. Rockwood and Green's Fractures in Adults. JB Lippincott, Philadelphia 1991; 1442–1479
- Kaempffe F A., Bone L B., Border J R. Open reduction and internal fixation of acetabular fractures: heterotopic ossification and other complications of treatment. J Orthop Trauma 1991; 5: 439–445
- Reinert C M., Bosse M J., Poka A, Schacherer T, Brum-back R J., Burgess A R. A modified extensile exposure for the treatment of complex or malunited acetabular fractures. 1988; 70A: 329–336, J Bone Joint Surg
- Brown G A., Willis M C., Firoozbakhsh K, Barmada A. Computed tomography image guided surgery in complex acetabular fractures. CORR 2000; 370: 219–226
- Starr A J., Reinert C M., Jones A L. Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 1998; 12: 51–58
- Gay S B., Sistrom C, Wang G J., Kahler D M., Boman T, McHugh N, Goitz H T. Percutaneous screw fixation of acetabular fractures with CT guidance: Preliminary results of a new technique (letter). AJR 1992; 158: 819–822
- Ludwig A L., Suhm N, Kalm A, Regazzoni P, et al. Coronal acetabular fractures: the anterior approach in computed tomography-navigated minimally invasive percutaneous fixation. Cardiovasc Intervent Radiol 2000; 23: 327–331
- Zura R D., Kahler D M. A transverse acetabular nonunion treated with computer-assisted percutaneous internal fixation. J Bone Joint Surg Am 2000; 82: 219–224
- Parker P J., Copeland C. Percutaneous fluoroscopic screw fixation of acetabular fractures. Injury 1997; 28(9–10)597–600
- Kahler D M., Zura R (1997) Evaluation of a computer integrated surgical technique for percutaneous fixation of transverse acetabular fractures. Proceedings of First Joint Conference on Computer Vision, Virtual Reality and Robotics in Medicine and Medical Robotics and Computer-Assisted Surgery (CVRMed-MRCAS'97), GrenobleFrance, March, 1997, J Troccaz, E Grimson, R Mösges. Springer, Berlin, 565–572, Lecture Notes in Computer Science 1205.
- Johanson N A., Charlson M E., Szatrowski T P., Ranawat C S. A self-administered hip rating questionnaire for the assessment of outcome after total hip replacement. J Bone Joint Surg Am 1992; 74: 58–59
- Norris B L., Hahn D H., Bosse M J., Kellam J F., Sims S H. Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery. J Orthop Trauma 1999; 13(6)414–417
- Mayo K A. Open reduction and internal fixation of fractures of the acetabulum: results in 163 fractures. Clin Orthop Rel Res 1994; 305: 31–37
- Wright R, Barrett K, Christie M J., Johnson K D. Long-term follow-up of open reduction and internal fixation. J Orthop Trauma 1994; 8: 397–403
- Routt M LC, Kregor P J., Simonian P T., et al. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 1995; 9: 207–214
- Routt M LC, Simonian P T., Grujie L. The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma 1995; 9: 35–44
- Kahler D M. Virtual fluoroscopy: a tool for decreasing radiation exposure during femoral intramedullary nailing. Syllabus of Fifth Annual North American Program on Computer Assisted Orthopaedic Surgery (CAOS USA), Pittsburgh, PA. July, 2001; 167–170
- Gundestrup M, Storm H H. Radiation-induced acute myeloid leukaemia and other cancers in commercial jet cockpit crew: a population-based cohort study. Lancet 1999; 354: 2029–2031