References
- Defrise M, Clack R. A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection. IREE Trans Med Imaging 1994;13:186–95.
- Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am 1984;1:612–9.
- Higgins TF, Baumgaertner MR. Diagnosis and treatment of fractures of the talus: a comprehensive review of the literature. Foot Ankle Int 1999;20:595–604.
- Schulze W, Richter J, Klapperich T, Muhr G. Functional results after operative therapy for talus fractures. Chirurg 1998;69:1207–13.
- Jerosch J, Malms J, Castro M, Wagner R, Wiesner L. Accuracy of pedicle screw placement in lumbar vertebrae. Z Orthop 1992;130:479–83.
- Routt ML, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 1997;11:584–9.
- Hernigou P, Besnard P. Articular penetration is more likely in Garden-I fractures of the hip. J Bone Joint Surg Br 1997;79:285–8.
- Rock C, Linsenmaier U, Brandl R, Kotsianos D, Wirth S, Kaltschmidt R, Euler E, Mutschler W, Pfeifer KJ. Presentation of a new mobile C-arm image amplifier (Iso-C-3D): initial results with three-dimensional CT-imaging. Unfallchirurg 2001;104:827–33.
- Kotsianos D, Rock C, Euler E, Wirth S, Linsenmaier U, Brandl R, Mutschler W, Pfeifer KJ. Three-dimensional imaging with an isocentric mobile C-arm (Siemens TSO-C-3D). Preliminary results for different joint fractures in comparison with plain radiography and computed tomography. Unfallchirurg 2001;104:834–8.
- Kotsianos D, Rock C, Wirth S, Linsenmaier U, Brandl R, Fischer T, Euler E, Mutschler W, Pfeifer KJ, Reiser M. Detection oftibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens TSO-C-3D): comparison with plain films and spiral CT. Fortschr Röntgenstr 2002;174:82–7.
- Heining SM, Euler E, Wirth S, Riquarts C, Mutschler W. New method of 3D-imaging with an isocentric C-arm and application in pedicle screw insertion. Syllabus of the Fifth Annual North American Program on Computer Assisted Orthopaedic Surgery (CAOS USA, 2001), July 2001, Pittsburgh, PA. p 217–8.
- Linsenmaier U, Rock C, Euler E, Wirth S, Brandl R, Kotsianos D, Mutschler W, Pfeifer KJ. New method of C-arm based isocentric tomography–feasibility. Radiology 2002;224:286–92.
- Nolte LP, Wälti H, Fujita H, Zheng G, Seissler W, Hey J, Kusch J. A novel mobile C-arm system for use in image guided surgery – a feasibility study. Proceedings of the First Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS-International 2001), February 2001, Davos, Switzerland. p 49.
- Wendl K, von Recum J, Wentzensen A, Grutzner PA. Iso-C3D assisted navigated implantation of pedicle screws in the thoracic and lumbar spine. Unfallchirurg 2003;106:907–13.
- Arand M, Schempf M, Kinzl L, Fleiter T, Pless D, Gebhard F. Precision in standardized Iso-C-Arm based navigated boring on the proximal femur. Unfallchirurg 2003;104:1150–6.
- Euler E, Wirth S, Linsenmaier U, Mutschler W, Pfeifer KJ, Hebecker A. Comparative analysis of the quality of mobile C-arm three-dimensional imaging of the talus. Unfallchirurg 2001;104:839–46.
- Wirth S, Euler E, Mutschler W, Pfeifer KJ. C-Arm based computed tomography — a comparative study. Tn: Lemke HE, Vannier MW, Tnamura K, Farman AG, Doi K, editors. Computer Assisted Radiology and Surgery. Proceedings of the 15th International Congress and Exhibition (CARS 2001), June 2001, Berlin. Amsterdam: Elsevier. p 408–13.
- De Lee JC. Fractures and dislocations of the foot. In: Mann RA, Coughin MJ, editors, Surgery of the foot and ankle. 6th ed. St. Louis: Mosby; 1993. p 1627–40.
- Ebraheim NA, Sabry FF, Nadim Y. Internal architecture of the talus: implication for talar fracture. Foot Ankle Int 1999;20:794–6.
- Wechsler RJ, Schweitzer ME, Karasick D, Deely DM, Glaser JB. Helical CT of talar fractures. Skeletal Radiol 1997;26:137–42.
- Nolte LP. Computer aided fixation of spinal implants. J Image Guid Surg 1995;1:88–93.
- Caversaccio M, Bächler R, Lädrach K, Schroth G, Nolte LP, Häusler R. The ‘Bernese’ frameless optical computer aided surgery system. Comput Aided Surg 1999;4:328–34.
- Nolte LP, Zamorano L, Visarius H, Berlemann U, Langlotz F, Arm E, Schwarzenbach O. Clinical evaluation of a system for precision enhancement in spine surgery. Clin Biomech 1995;10:293–303.
- Foley KT, Smith MM. Image-guided spine surgery. Neurosurg Clin N Am 1996;7:171–86.
- Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 2000;9:235–40.
- Gebhard F, Kinzl L, Arand M. The limits of CT based computer navigation in spinal surgery. Unfallchirurg 2000;103:696–701.
- Marmulla R, Niederdellmann H. Computer assisted bone segment navigation. J Craniomaxillofac Surg 1998;26:347–59.