References
- Delp S L., Stulberg S D., Davies B, Picard F, Leitner F. Computer assisted knee replacement. Clin Orthop 1998; 354: 49–56
- Stern S H., Insall J N. Posterior stabilised prosthesis: results after follow-up of nine to twelve years. J Bone Joint Surg Am 1992; 74: 980–6
- Vince K G., Insall J N, Kelly M A. The total condylar prosthesis: 10 to 12 year results of a cemented knee replacement. J Bone Joint Surg Br 1989; 71: 793–7
- Dorr L D., Boiardo R A. Technical considerations in total knee arthroplasty. Clin Orthop 1986; 205: 5–11
- Stulberg S D., Loan P, Sarin V. Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 2002; 84(suppl 2)90–8
- Jeffery R S., Morris R W., Denham R A. Coronal alignment after total knee replacement. J Bone Joint Surg Br 1991; 73: 709–14
- Ritter M A., Faris P M., Keating E M., Meding J B. Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop 1994; 299: 153–6
- Ecker M L., Lotke P A., Windsor R E., Cella J P. Long-term results after total condylar knee arthroplasty: significance of radiolucent lines. Clin Orthop 1987; 216: 151–8
- Garg A, Walker P S. Prediction of total knee motion using a three-dimensional computer-graphics model. J Biomech 1990; 23: 45–58
- Teter K E., Bregman D, Colwell C W. Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop 1995; 321: 106–10
- Stulberg S D., Picard K, Saragaglia D. Computer-assisted total knee replacement arthroplasty. Op Tech Orthop 2000; 10: 25
- Matsen F A., Garbini J L., Sidles J A., Pratt B, Baugarten P, Kaiura R. Robotic assistance in orthopaedic surgery: a proof of principle using distal femoral arthroplasty. Clin Orthop 1993; 296: 178–86
- Berger R A., Rubash H E., Seel M J., Thompson W H., Crossett L S. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop 1993; 286: 40–7
- Oswald M H., Jakob R P., Schneider E, Hoogewoud H M. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 1993; 8: 419–26
- Wasielewski R C., Galante J O., Leighty R M., Natarajan R N., Rosenberg A G. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop 1994; 299: 31–43
- Krackow K A., Bayers-Thering M, Phillips M J., Bayers-Thering M, Mihalko W M. A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted total knee arthroplasty. Orthopedics 1999; 22: 698–702
- Nofrini L, Slomczykowski M, Iacono F, Marcacci M. Evaluation of accuracy in ankle center location for tibial mechanical axis identification. J Invest Surg 2004; 17: 23–9