The Björk-Shiley and Ionescu-Shiley Heart Valve Prostheses In Vitro Comparison of Their Hydrodynamic Performance in the Mitral Position

, &
Pages 201-209 | Received 02 May 1983, Published online: 12 Jul 2009

References

  • Aberg B., Henze A. Comparison between the in vitro flow dynamics of the standard and the convexo-concave Björk-Shiley tilting disc valve prostheses. Scand J Thorac Cardiovasc Surg 1979; 13: 177
  • Björk V. O., Book K., Holmgren A. Significance of position and opening angle of the Björk-Shiley tilting disc valve in mitral surgery. Scand J Thorac Cardiovasc Surg 1973; 7: 187
  • Dellsperger K. C., Wieting D. W., Baehr D. A., Bard R. J., Brugger J. P., Harrison E. C. Regurgitation of prosthetic heart valves—dependence on heart rate and cardiac output. Am J Cardiol 1983; 51: 321
  • Gabbay S., Yellin E. L., Frishman W. H., Frater R. W. M. In vitro hydrodynamic comparison of St. Jude, Björk-Shiley, and Hall-Kaster valves. Trans Am Soc Artif Intern Organs 1980; 26: 231
  • Gabbay S., Frater R. W. M. In vitro comparison of the newer heart valve bioprostheses in the mitral and aortic positions. Cardiac bioprostheses, proceedings of the second international symposium, L. H. Cohn, V. Gallucci. York Medical Books, New York City 1982; section VII: 456–468
  • Gentle C. R. Characterisation of leakage flow in cardiac valve prostheses. ESAO Proc 1982; 9: 102
  • Ionescu M. I., Tandon A. P., Saunders N. R., Chidambaram M., Smith D. R. Clinical durability of the pericardial xenograft valve: 11 years experience. Cardiac bioprostheses, proceedings of the second international symposium, L. H. Cohn, V. Gallucci. York Medical Books, New York City 1982; section I: 43–60
  • Kennedy J. W., Yarnall S. R., Murray J. A., Figley M. M. Quantitative angiocardiography. IV. Relationship of left atrial and ventricular pressure and volume in mitral valve disease. Circulation 1970; 41: 817
  • Scotten L. N., Walker D. K., Smith D. W., Brownlee R. T. A versatile pump for simulating physiological fluid flows. AAMI Proc 1983; 18: 108
  • Scotten L. N., Racca R. G., Nugent A. H., Walker D. K., Brownlee R. T. New tilting disc cardiac valve prostheses—In vitro comparison of their hydro-dynamic performance in the mitral position. J Thorac Cardiovasc Surg 1981; 82: 136
  • Scotten L. N., Walker D. K., Brownlee R. T. Construction and evaluation of a hydromechanical simulation facility for the assessment of mitral valve prostheses. J Med Eng Technol 1979; 3: 11
  • Stevenson D. M., Yoganathan A. P., Franch R. H. The Björk-Shiley heart valve prosthesis—Flow characteristics of the new 70° model. Scand J Thorac Cardiovasc Surg 1982; 16: 1
  • Walker D. K., Scotten L. N., Racca R. G., Brownlee R. T. Acquisition and analysis of data obtained from the in vitro testing of replacement heart valves. AAMI Proc 1983; 18: 130
  • Yoganathan A. P., Corcoran W. H. Pressure drops across prosthetic aortic heart valves under steady and pulsatile flow. In vitro measurements. J Biomech 1979; 12: 153

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.