- Aspenberg P, Wagner P, Nilsson KG, Ranstam J. Fixed or loose? Dochotomy in RSA data for cemented cups. Acta Orthop 2008;79(4): 467-73.
- Braun RM. Total joint replacement at the base of the thumb – preliminary report. J Hand Surg Am 1982;7:245-51
- Bryant D, Havey TC, Roberts R, Guyatt G. How many patients? How many limbs? Analysis of patients or limbs in the orthopaedic literature: A systematic review. J Bone Joint Surg (Am) 2006;88(1): 41-5.
- Cooney WP, Chao EY. Biomechanical analysis of static forces in the thumb during hand function. J Bone Joint Surg (Am) 1977;59:27-36
- Cooney WP, Linscheid RP, Askew LJ. Total arthroplasty of the thumb trapeziometacarpal joint. Clin Orthop 1987;220:35-45
- de la Caffiniere JY, Aucouturier P. Trapezio-metacarpal arthroplasty by total prosthesis. Hand 1979;11:41-6
- Eaton RG, Glickel SZ. Trapeziometacarpal osteoarthritis. Staging as a rationale for treatment. Hand Clin 1987;3:455-71
- Hansen TB. Elektra TM. Total joint prosthesis. In: Wrist and Hand Joint Replacements. FESSH Instructional Course 2011 (Ed Magne Røkkum).
- Hansen TB, Homilius M. Failed total carpometacarpal joint prosthesis of the thumb: results after resection arthroplasty. Scand J Plast Reconstr Surg Hand Surg 2010;44:171-4
- Hansen TB, Vainorius D. High loosening rate of the Moje Acamo prosthesis for treating osteoarthritis of the trapeziometacarpal joint. J Hand Surg Eur 2008;33:571-4
- Hansen TB, Snerum L. Elektra trapeziometacarpal prosthesis for treatment of osteoarthrosis of the basal joint of the thumb. Scand J Plastic Reconstr Hand Surg 2008;42:316-19
- Hansen TB, Larsen K, Bjergelund L, Stilling M. Trapeziometacarpal joint implants can be evaluated by roentgen stereophotogrammetric analysis. J Hand Surg Eur 2010;35:480-5
- Hansen TB, Meier M, Møller MC, . Primary cup fixation with different designs of trapeziometacarpal total joint trapezium components: a radiostereometric analysis in a pig bone model. J Hand Surg Eur 2011;36:285-90
- Hansen TB, Sørensen OG, Kirkeby L, . Computed tomography improves intra-observer reliability, but not the inter-observer reliability of the Eaton-Glickel classification. J Hand Surg Eur 2012, Epub ahead of print
- Hernández-Cortés P, Pajares-López M, Robles-Molina MJ, . Two-year outcomes of Elektra prosthesis for trapeziometacarpal osteoarthritis: a longitudinal cohort study. J Hand Surg Eur 2012;37:130-7
- Kaptein BL, Valstar ER, Stoel BC, . A new model-based RSA method validated using CAD models and models from reversed engineering. J Biomech 2003;36:873-82
- Klahn A, Nygaard M, Gvozdenovic R, Boeckstyns M EH. Elektra prosthesis for trapeziometacarpal osteoarthritis: a follow-up of 39 consecutive cases. J Hand Surg Eur 2012; Epub ahead of print
- Kärrholm J, Borssén B, Löwenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg (Br) 1994;76:912-7.
- Nelissen RG, Pijls BG, Kärrholm J, . RSA and registries: the quest for phased introduction of new implants. J Bone Joint Surg (Am) (Suppl 3) 2011;21:93: 62-5.
- Perez-Ubeda MJ, Garcia-Lopez A, Martinez FM, . Results of the cemented SR trapeziometacarpal prosthesis in the treatment of thumb carpometacarpal osteoarthritis. J Hand Surg (Am) 2003;28:917-25
- Pijls BG, Nieuwenhuijse MJ, Fiocco M, . Early proximal migration of cups is associated with late revision in THA. A systematic review and meta-analysis of 26 RSA studies in 49 survival studies. Acta Orthop 2012a;83(6): 583-91.
- Pijls BG, Valstar ER, Nouta KA, . Early migration of tibial components is associated with late revision. A systematic review and meta-analysis of 21,000 knee arthroplasties. Acta Orthop 2012b;83(6): 614-24.
- Regnard PJ. Electra trapezio metacarpal prosthesis: Results of the first 100 cases. J Hand Surg Br 2006;31:621-8
- Ryd L, Albrektsson BE, Carlsson L, . Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg (Br) 1995;77:377-83
- Ryd L, Yuan X, Löfgren H. Methods for determining the accuracy of radiostereometric analysis (RSA). Acta Orthop Scand 2000;71:403-8
- Søndergaard L, Konradsen L, Rechnagel K. Long-term follow-up of the cemented Caffiniere prosthesis for trapeziometacarpal arthroplasty. J Hand Surg Br 1991;16:428-30
- Ulrich-Vinther M, Puggaard H, Lange B. Prospective 1-year follow-up study comparing joint prosthesis with tendon interposition arthroplasty in treatment of trapeziometacarpal osteoarthritis. J Hand Surg (Am) 2008;33:1369-77
- Wachtl SW, Guggenheim PR, Sennwald GR. Cemented and non-cemented replacement of the trapeziometacarpal joint. J Bone Joint Surg (Br) 1998;80:121-5
- Valstar ER, Gill R, Ryd L, . Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 2005;76:563-72
- Van Capelle H GJ, Elzenga P, van Horn JR. Long-term result and loosening analysis of de la Caffiniére replacement of the trapeziometacarpal joint. J Hand Surg (Am) 1999;24:476-82
Acta Orthopaedica
Volume 84, 2013 - Issue 1
Open access
1,274
Views
40
CrossRef citations to date
0
Altmetric
Hand
Equally good fixation of cemented and uncemented cups in total trapeziometacarpal joint prostheses
A randomized clinical RSA study with 2-year follow-up
Torben Bæk HansenDepartment of Orthopaedics,
Section of Hand Surgery, and Orthopaedic Research Unit, Holstebro Regional Hospital, Holstebro, Denmark.Correspondence[email protected]
& Maiken StillingDepartment of Orthopaedics,
Section of Hand Surgery, and Orthopaedic Research Unit, Holstebro Regional Hospital, Holstebro, Denmark.
Pages 98-105
|
Received 07 May 2012, Accepted 15 Oct 2012, Published online: 23 Jan 2013
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.