- Black J. Biologic performance of tantalum. Clin Mater 1994; 16: 167–73.
- Davis JR. Tantalum and tantalum alloys. Corrosion of nonferrous alloy weldments. In: Corrosion of Weledments. Chapter 8. ASMInternational. 2006: 164.
- Fernández-Fairen M, Murcia A, Blanco A, Meroño A, Murcia A Jr, Ballester J. Revision of failed total hip arthroplasty acetabular cups to porous tantalum components A 5-year follow-up study. J Arthroplasty 2010; 25 (6): 865-72.
- Issack PS, Nousiainen M, Beksac B, Helfet DL, Sculco TP, Buly RL. Acetabular component revision in total hip arthroplasty. Part II: management of major bone loss and pelvic discontinuity. Am J Orthop 2009; 38 (11): 550-6.
- Jafari SM, Bender B, Coyle C, Parvizi J, Sharkey PF, Hozack WJ. Do tantalum and titanium cups show similar results in revision hip arthroplasty? Clin Orthop 2010; (468) (2): 459–65.
- Kato H, Nakamura T, Nishiguchi S, Matsusue Y, Kobayashi M, Miyazaki T, Kim HM, Kokubo T. Bonding of alkali- and heat-treated tantalum implants to bone. J Biomed Mater Res 2000; 539 (1): 28–35.
- Lavigne M, Belzile EL, Roy A, et al. Comparison of whole-blood metal ion levels in four types of metal-on metal femoral head total hip arthroplasty: the potential influence of the adapter sleeve. J Bone Joint Surg (Am) (Suppl 2) 2011; 93: 128.
- Levine B, Della Valle CJ, Jacobs JJ. Applications of porous tantalum in total hip arthroplasty J Am Acad Orthop Surg. 2006a; 14: 646–55.
- Levine BR, Sporer S, Poggie RA, Della Valle CJ, Jacobs JJ. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials 2006b; 27: 4671–81.
- Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop 2004; (429): 201-8.
- Roberge P. Corrosion basics. An introduction. 2nd Edition. NACE press. 2006: 76-92.
- Rodushkin I, Engstrom E, Stenberg A, Baxter DC. Determination of low-abundance elements at ultra-trace levels in urine and serum by inductively coupled plasma–sector field mass spectrometry. Anal Bional Chem 2004; 380: 247-57.
- Romaguera C, Vilaplana J. Contact dermatitis from tantalum. Contact Dermatitis 1995; 32: 184.
- Werman BS, Rietschel RL. Chronic urticaria from tantalum staples. Arch Dermatol 1981; 117: 438-9.
- Zimmer Inc. Trabecular Metal™ Technology the Best Thing Next to Bone. 2006; 97-7255-062-00 7.5ML
Acta Orthopaedica
Volume 85, 2014 - Issue 6
Open access
1,170
Views
14
CrossRef citations to date
0
Altmetric
Case report
Metallosis and elevated serum levels of tantalum following failed revision hip arthroplasty— a case report
George C BabisSecond Department of Orthopaedics, Konstantopouleio General Hospital N. Ionia,
University of Athens Medical School, N. Ionia, AthensCorrespondence[email protected]
, Nikolaos A StavropoulosFirst Department of Orthopaedics, “ATTIKON” University General Hospital, University of Athens Medical School,
Chaidari, Athens
, Gregory SasalosFirst Department of Orthopaedics, “ATTIKON” University General Hospital, University of Athens Medical School,
Chaidari, Athens
, Maria Ochsenkuehn-PetropoulouLaboratory of Inorganic and Analytical Chemistry, School of Chemical Engineering,
National Technical University of Athens, Athens
& Panagiotis MegasDepartment of Orthopaedics,
School of Medicine, University of Patras, Patras, Greece.
Pages 677-680
|
Received 17 Aug 2013, Accepted 24 Mar 2014, Published online: 20 Aug 2014
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.