- Adam F, Pape D, Johann S, Kohn D. Postoperative migration of cementless titanium hip-stems. Clinical study with Roentgen Stereometric Analysis (RSA). J Bone Joint Surg Br 2004; 86-B: 377-37e.
- AJR. Australian Orthopaedic Association National Joint Replacement Registry Annual Report 2013: https://aoanjrr.dmac.adelaide.edu.au/nl/annual-reports-2013.
- Aldinger P R, Breusch S J, Lukoschek M, Mau H, Ewerbeck V, Thomsen M. A ten- to 15-year follow-up of the cementless Spotorno stem. J Bone Joint Surg Br 2003a; 85 (2): 209-14.
- Aldinger P R, Thomsen M, Mau H, Ewerbeck V, Breusch S J. Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand 2003b; 74 (3): 253-8.
- Alfaro-Adrian J, Gill H S, Murray D W. Cement migration after THR. A comparison of Charnley Elite and Exeter femoral stems using RSA. J Bone Joint Surg Br 1999; 81 (1): 130-4.
- Alfaro-Adrian J, Gill HS, Murray DW. Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems. J Arthroplasty 2001; 16 (5): 598-606.
- Badhe N P, Quinnell R C, Howard P W. The uncemented Bi-Contact total hip arthroplasty. J Arthroplasty 2002; 17 (7): 896-901.
- Badhe S, Livesley P. Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up). Int Orthop 2006; 30 (1): 31-4.
- The Beyond Compliance Advisory Group. http://www.beyondcompliance.org.uk.
- Bulstrode CJ, Murray DW, Carr AJ, Pynsent PB, Carter SR. Designer hips. BMJ 1993; 306 (6880): 732-3.
- Canales C V, Panisello Sebastia J J, et al. Ten-year follow-up of an anatomical hydroxyapatite-coated total hip prosthesis. Int Orthop 2006; 30 (2): 84-90.
- Capello W N, D’Antonio J A, Feinberg J R, Manley M T, Naughton M. Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty 2008; 23 (7 Suppl): 39-43.
- Castoldi F, Rossi R, La Russa M, Sibelli P, Rossi P, Ranawat A S. Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty. J Arthroplasty 2007; 22 (3): 363-8.
- Chen F S, Di Cesare P E, Kale A A, et al. Results of cemented metal-backed acetabular components: a 10-year-average follow-up study. J Arthroplasty 1998; 13 (8): 867-73.
- Chiu K H, Shen W Y, Tsui H F, Chan K M. Experience with primary Exeter total hip arthroplasty in patients with small femurs - Review at average follow-up period of 6 years. J Arthroplasty 1997; 12 (3): 267-72.
- Chiu K H, Shen W Y, Cheung K W, Tsui H F. Primary Exeter total hip arthroplasty in patients with small femurs: a minimal of 10 years follow-up. J Arthroplasty 2005; 20 (3): 275-81.
- de Kam D C, Klarenbeek R L, Gardeniers J W, Veth R P, Schreurs B W. The medium-term results of the cemented Exeter femoral component in patients under 40 years of age. J Bone Joint Surg Br 2008; 90 (11): 1417-21.
- Derbyshire B, Porter ML. Re: the premature failure of the Charnley Elite-Plus stem: a confirmation of RSA predictions. J Bone Joint Surg Br 2006; 88 (12): 1676; author reply -7.
- Derbyshire B, Porter M L. A study of the Elite Plus femoral component using radiostereometric analysis. J Bone Joint Surg Br 2007; 89 (6): 730-5.
- Digas G, Thanner J, Anderberg C, Karrholm J. Fluoride-containing acrylic bone cement in total hip arthroplasty. Randomized evaluation of 97 stems using radiostereometry and dual-energy X-ray absorptiometry. J Arthroplasty 2005; 20 (6): 784-92.
- Digas G, Karrholm J, Thanner J. Addition of fluoride to acrylic bone cement does not improve fixation of a total hip arthroplasty stem. Clin Orthop Relat Res 2006; 448: 58-66.
- Eingartner C, Volkmann R, Winter E, et al. Results of an uncemented straight femoral shaft prosthesis after 9 years of follow-up. J Arthroplasty 2000; 15 (4): 440-7.
- Eingartner C, Heigele T, Dieter J, Winter E, Weise K. Long-term results with the BiCONTACT system--aspects to investigate and to learn from. Int Orthop 2003; 27 Suppl 1: S11-5.
- Epinette J A, Manley M T. Uncemented stems in hip replacement--hydroxyapatite or plain porous: does it matter? Based on a prospective study of HA Omnifit stems at 15-years minimum follow-up. Hip Int 2008; 18 (2): 69-74.
- Espehaug B, Havelin L I, Engesaeter L B, Vollset S E, Langeland N. Early revision among 12,179 hip prostheses - A comparison of 10 different brands reported to the Norwegian Arthroplasty Register, 1987-1993. Acta Orthop Scand 1995; 66 (6): 487-93.
- Faro L M, Huiskes R. Quality assurance of joint replacement. Legal regulation and medical judgement. Acta Orthop Scand Suppl 1992; 250: 1-33.
- Fiocco M, Putter H, van Houwelingen J C. Meta-analysis of pairs of survival curves under heterogeneity: a Poisson correlated gamma-frailty approach. Stat Med 2009a; 28 (30): 3782-97.
- Fiocco M, Putter H, Van Houwelingen J C. A new serially correlated gamma-frailty process for longitudinal count data. Biostatistics 2009b; 10 (2): 245-57.
- Fiocco M, Stijnen T, Putter H. Meta-analysis of time-to-event outcomes using a hazard-based approach: Comparison with other models, robustness and meta-regression. Computational Statistics and Data Analysis 2012; 56 (5): 1028-37.
- Gallo J, Langova K, Havranek V, Cechova I. Poor survival of ABG I hip prosthesis in younger patients. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2008; 152 (1): 163-8.
- Garellick G, Malchau H, Regner H, Herberts P. The Charnley versus the Spectron hip prosthesis: radiographic evaluation of a randomized, prospective study of 2 different hip implants. J Arthroplasty 1999; 14 (4): 414-25.
- Garellick G, Malchau H, Herberts P. Survival of hip replacements. A comparison of a randomized trial and a registry. Clin Orthop Relat Res 2000; (375): 157-67.
- Gill H S, Alfaro-Adrian J, Alfaro-Adrian C, McLardy-Smith P, Murray D W. The effect of anteversion on femoral component stability assessed by radiostereometric analysis. J Arthroplasty 2002; 17 (8): 997-1005.
- Glyn-Jones S, Hicks J, Alfaro-Adrian J, Gill H S, McLardy-Smith P, Murray D W. The influence of cement viscosity on the early migration of a tapered polished femoral stem. Int Orthop 2003; 27 (6): 362-5.
- Glyn-Jones S, Alfaro-Adrian J, Murray D W, Gill H S. The influence of surgical approach on cemented stem stability: an RSA study. Clin Orthop Relat Res 2006; 448: 87-91.
- Grant P, Aamodt A, Falch J A, Nordsletten L. Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem A randomized study with use of radiostereometry and bone densitometry. J Orthop Res 2005; 23 (6): 1280-5.
- Grewal R, Rimmer M, Freeman M. Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacement. J Bone Joint Surg Br 1992; 74 (2): 239-42.
- Guther D, Pap G, Bamert P, Eggli S. [Long-term results with the cemetless CLS stem in hip replacement]. Z Orthop Ihre Grenzgeb 2003; 141 (3): 309-15.
- Hallan G, Lie S A, Furnes O, Engesaeter L B, Vollset S E, Havelin L I. Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br 2007; 89 (12): 1574-80.
- Hauptfleisch J, Glyn-Jones S, Beard D J, Gill H S, Murray D W. The premature failure of the Charnley Elite-Plus stem: a confirmation of RSA predictions. J Bone Joint Surg Br 2006; 88 (2): 179-83.
- Havelin L I, Engesaeter L B, Espehaug B, Furnes O, Lie S A, Vollset S E. The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties. Acta Orthop Scand 2000; 71 (4): 337-53.
- Herrera A, Canales V, Anderson J, Garcia-Araujo C, Murcia-Mazon A, Tonino A J. Seven to 10 years followup of an anatomic hip prosthesis: an international study. Clin Orthop Relat Res 2004; (423): 129-37.
- Hook S, Moulder E, Yates P J, Burston B J, Whitley E, Bannister G C. The Exeter Universal stem: a minimum ten-year review from an independent centre. J Bone Joint Surg Br 2006; 88 (12): 1584-90.
- Hozack W J, Rothman R H, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res 1996; (333): 217-25.
- Huiskes R, Verdonschot N, Nivbrant B. Migration, stem shape, and surface finish in cemented total hip arthroplasty. Clin Orthop Relat Res 1998; (355): 103-12.
- ISO. Implants for surgery -Roentgen stereophotogrammetric analysis for the assessment of migration of orthopaedic implants (16087:2013): http://www.iso.org/iso/home/store/catalogue_tc/catalogue_detail.htm?csnumber=55662.
- Issack P S, Botero H G, Hiebert R N, et al. Sixteen-year follow-up of the cemented spectron femoral stem for hip arthroplasty. J Arthroplasty 2003; 18 (7): 925-30.
- Iwase T, Wingstrand I, Persson B M, Kesteris U, Hasegawa Y, Wingstrand H. The ScanHip total hip arthroplasty: radiographic assessment of 72 hips after 10 years. Acta Orthop Scand 2002; 73 (1): 54-9.
- Jacobsson S A, Ivarsson I, Djerf K, Wahlstrom O. Stem loosening more common with ITH than Lubinus prosthesis - a 5-year clinical and radiographic follow-up of 142 patients. Acta Orthop Scand 1995; 66 (5): 425-31.
- Johnsson R, Franzen H, Nilsson L T. Combined survivorship and multivariate analyses of revisions in 799 hip prostheses. A 10- to 20-year review of mechanical loosening. J Bone Joint Surg Br 1994; 76 (3): 439-43.
- Kalairajah Y, Azurza K, Molloy S, Hulme C, Cronin M, Drabu K J. Is the Charnley evolution working? A five-year outcome study. Acta Orthop Belg 2004; 70 (4): 315-21.
- Kale A A, Della Valle C J, Frankel V H, Stuchin S A, Zuckerman J D, Di Cesare P E. Hip arthroplasty with a collared straight cobalt-chrome femoral stem using second-generation cementing technique - A 10-year-average follow-up study. J Arthroplasty 2000; 15 (2): 187-93.
- Karrholm J, Snorrason F. Subsidence, tip, and hump micromovements of noncoated ribbed femoral prostheses. Clin Orthop Relat Res 1993; (287): 50-60.
- Karrholm J, Borssen B, Lowenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 1994; 76 (6): 912-7.
- Kim Y H, Kim J S, Yoon S H. Long-term survivorship of the Charnley Elite Plus femoral component in young patients. J Bone Joint Surg Br 2007; 89 (4): 449-54.
- Lee G Y, Srivastava A, D’Lima D D, Pulido P A, Colwell C WJr. Hydroxyapatite-coated femoral stem survivorship at 10 years. J Arthroplasty 2005; 20 (7 Suppl 3): 57-62.
- Lewthwaite S C, Squires B, Gie G A, Timperley A J, Ling R S M. The Exeter (TM) Universal hip in patients 50 years or younger at 10-17 years’ followup. Clin Orthop Relat Res 2008; 466 (2): 324-31.
- Liow R Y, Murray D W. Which primary total knee replacement? A review of currently available TKR in the United Kingdom. Ann R Coll Surg Engl 1997; 79 (5): 335-40.
- Makela K, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V. Cemented total hip replacement for primary osteoarthritis in patients aged 55 years or older: results of the 12 most common cemented implants followed for 25 years in the Finnish Arthroplasty Register. J Bone Joint Surg Br 2008; 90B (12): 1562-9.
- Malchau H. On the importance of stepwise introduction of new hip implant technology: assessment of total hip replacement using clinical evaluation, radiostereometry, digitised radiography and a national hip registry. Ortopedisk kirurgi 1995.
- Malchau H. Introducing new technology: a stepwise algorithm. Spine (Phila Pa 1976) 2000; 25 (3): 285.
- Manley M T, Capello W N, D’Antonio J A, Edidin A A, Geesink R G T. Fixation of acetabular cups without cement in total hip arthroplasty - A comparison of three different implant surfaces at a minimum duration of follow-up of five years. J Bone Joint Surg Am 1998; 80A (8): 1175-85.
- McCombe P, Williams S A. A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial. J Bone Joint Surg Br 2004; 86 (3): 344-9.
- McCulloch P, Altman D G, Campbell W B, et al. No surgical innovation without evaluation: the IDEAL recommendations. Lancet 2009; 374 (9695): 1105-12.
- McLaughlin J R, Lee K R. Total hip arthroplasty with an uncemented femoral component - Excellent results at ten-year follow-up. J Bone Joint Surg Br 1997; 79B (6): 900-7.
- McLaughlin J R, Lee K R. Total hip arthroplasty in young patients. 8- to 13-year results using an uncemented stem. Clin Orthop Relat Res 2000; (373): 153-63.
- McLaughlin J R, Lee K R. The outcome of total hip replacement in obese and non-obese patients at 10-to 18-years. J Bone Joint Surg Br 2006; 88B (10): 1286-92.
- McLaughlin J R, Lee K R. Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg Am 2008; 90 (6): 1290-6.
- Min B W, Song K S, Bae K C, Cho C H, Kang C H, Kim S Y. The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component. J Arthroplasty 2008; 23 (3): 418-23.
- Mjoberg B, Selvik G, Hansson L I, Rosenqvist R, Onnerfalt R. Mechanical loosening of total hip prostheses. A radiographic and roentgen stereophotogrammetric study. J Bone Joint Surg Br 1986; 68 (5): 770-4.
- Mjoberg B, Franzen H, Selvik G. Early detection of prosthetic-hip loosening. Comparison of low- and high-viscosity bone cement. Acta Orthop Scand 1990; 61 (3): 273-4.
- Muirhead-Allwood S K. Lessons of a hip failure. BMJ 1998; 316 (7132): 644.
- Murray D W, Carr A J, Bulstrode C J. Which primary total hip replacement? J Bone Joint Surg Br 1995; 77 (4): 520-7.
- Myers G J C, Morgan D, O’Dwyer K. Exeter-Ogee total hip replacement using the Hardinge approach; the ten to twelve year results. Hip Int 2008; 18 (1): 35-9.
- Nelissen R G, Garling E H, Valstar E R. Influence of cement viscosity and cement mantle thickness on migration of the Exeter total hip prosthesis. J Arthroplasty 2005; 20 (4): 521-8.
- Nelissen R G, Pijls B G, Karrholm J, Malchau H, Nieuwenhuijse M J, Valstar E R. RSA and registries: the quest for phased introduction of new implants. J Bone Joint Surg Am 2011; 93 Suppl 3: 62-5.
- NHS. National Institute for Clinical Excellence. Guidance on the selection of prostheses for primary total hip replacement. : http://www.nice.org.uk/nicemedia/pdf/Guidance_on_the_selection_of_hip_prostheses.pdf.
- Nieuwenhuijse M J, Valstar E R, Kaptein B L, Nelissen R G. Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups. Results from ten years of follow-up with roentgen stereophotogrammetric analysis (RSA). J Bone Joint Surg Am 2012; 94 (10): 874-80.
- Nivbrant B, Karrholm J, Soderlund P. Increased migration of the SHP prosthesis: radiostereometric comparison with the Lubinus SP2 design in 40 cases. Acta Orthop Scand 1999; 70 (6): 569-77.
- Nivbrant B, Karrholm J, Rohrl S, Hassander H, Wesslen B. Bone cement with reduced proportion of monomer in total hip arthroplasty: preclinical evaluation and randomized study of 47 cases with 5 years’ follow-up. Acta Orthop Scand 2001; 72 (6): 572-84.
- NJR. New Zealand National Joint Registry Annual Report 2012 (fourteen year report): http://www.nzoa.org.nz/nz-joint-registry.
- Nordsletten L, Aamodt A, Benum P, Grant P. The Unique customized prosthesis (UCP) is more stable than the cemented Elite Plus femoral stem. A randomized prospective study with radiostereometric one year follow up. J Bone Joint Surg Br 2004; 86-B: 401-40d.
- Ochs U, Eingartner C, Volkmann R, et al. >Prospective long-term follow-up of the cementless bicontact hip stem with plasmapore coating. Z Orthop Unfall 2007; 145 Suppl 1: S3-8.
- Ohnsorge J A, Davis J, Maus U, Saklak M, Weisskopf M, Wirtz D C. >Early polyethylene wear and excessive acetabular granuloma in an uncemented HA-coated total hip arthroplasty--midterm results of a prospective study. HSS J 2006; 2 (2): 114-20.
- Olofsson K, Digas G, Karrholm J. Influence of design variations on early migration of a cemented stem in THA. Clin Orthop Relat Res 2006; 448: 67-72.
- Oosterbos C J, Rahmy A I, Tonino A J. Hydroxyapatite coated hip prosthesis followed up for 5 years. Int Orthop 2001; 25 (1): 17-21.
- Oosterbos C J, Rahmy A I, Tonino A J, Witpeerd W. High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for 10 years. Acta Orthop Scand 2004; 75 (2): 127-33.
- Parvizi J, Sharkey P F, Hozack W J, Orzoco F, Bissett G A, Rothman R H. Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty. A concise follow-up of a previous report. J Bone Joint Surg Am 2004; 86-A (4): 783-6.
- Pijls B G, Dekkers O M, Middeldorp S, Valstar E R, van der Heide H J, Van der Linden-Van der Zwaag H M, Nelissen R G. AQUILA: assessment of quality in lower limb arthroplasty. An expert Delphi consensus for total knee and total hip arthroplasty. BMC Musculoskelet Disord 2011; 12: 173.
- Pijls B G, Nieuwenhuijse M J, Fiocco M, Plevier J W, Middeldorp S, Nelissen R G, Valstar E R. Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies. Acta Orthop Scand 2012a; 83 (6): 583-91.
- Pijls B G, Valstar E R, Nouta K A, Plevier J W, Fiocco M, Middeldorp S, Nelissen R G. Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties. Acta Orthop Scand 2012b; 83 (6): 614-24.
- Pivec R, Johnson A J, Mears S C, Mont M A. Hip arthroplasty. Lancet 2012; 380 (9855): 1768-77.
- Poon P C, Rennie J, Gray D H. Review of total hip replacement. The Middlemore Hospital experience, 1980-1991. N Z Med J 2001; 114 (1133): 254-6.
- Purtill J J, Rothman R H, Hozack W J, Sharkey P F. Total hip arthroplasty using two different cementless tapered stems. Clin Orthop Relat Res 2001; (393): 121-7.
- Putter H, Fiocco M, Stijnen T. Meta-analysis of diagnostic test accuracy studies with multiple thresholds using survival methods. Biom J 2010; 52 (1): 95-110.
- Rogers A, Kulkarni R, Downes E M. The ABG hydroxyapatite-coated hip prosthesis: one hundred consecutive operations with average 6-year follow-up. J Arthroplasty 2003; 18 (5): 619-25.
- Ryd L, Albrektsson B E, Carlsson L, Dansgard F, Herberts P, Lindstrand A, Regner L, Toksvig-Larsen S. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg Br 1995; 77 (3): 377-83.
- Savilahti S, Myllyneva I, Lindholm T S, Pajamaki K J, Nevalainen J, Laippala P. Clinical outcome and survival of Link RS total hip prosthesis. J Bone Joint Surg Br 1995; 77 (3): 369-73.
- Schemitsch E H, Bhandari M, Boden S D, et al. The evidence-based approach in bringing new orthopaedic devices to market. J Bone Joint Surg Am 2010; 92 (4): 1030-7.
- Schramm M, Keck F, Hohmann D, Pitto R P. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg 2000; 120 (7-8): 407-12.
- Schreiner U, Scheller G, Herbig J, Jani L. Mid-term results of the cementless CLS stem. A 7- to 11-year follow-up study. Arch Orthop Trauma Surg 2001; 121 (6): 321-4.
- SHAR. Swedish Hip Arthroplasty Registry Report 2011: http://www.shpr.se/en/Publications/DocumentsReports.aspx.
- Sheth U, Nguyen N A, Gaines S, Bhandari M, Mehlman C T, Klein G. New orthopedic devices and the FDA. J Long Term Eff Med Implants. 2009; 19 (3): 173-84.
- Siebold R, Scheller G, Schreiner U, Jani L. [Long-term results with the cement-free Spotorno CLS shaft]. Orthopade 2001; 30 (5): 317-22.
- Soballe K, Christensen F. Calcar resorption after total hip arthroplasty. J Arthroplasty 1988; 3 (2): 103-7.
- Soballe K, Christensen F, Luxhoj T. Hip replacement in obese patients. Acta Orthop Scand 1987a; 58 (3): 223-5.
- Soballe K, Olsen N J, Ejsted R, Christensen F, Luxhoj T. Revision of the uncemented hip prosthesis. Acta Orthop Scand 1987b; 58 (6): 630-3.
- Spotorno L, Romagnoli S, Ivaldo N, et al. The CLS system. Theoretical concept and results. Acta Orthop Belg 1993; 59 Suppl 1: 144-8.
- Stefansdottir A, Franzen H, Johnsson R, Ornstein E, Sundberg M. Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years. Acta Orthop Scand 2004; 75 (4): 408-14.
- Steimer O, Adam F, Johann S, Pape D. [Primary stability of cementless implanted hip stems made of titanium alloy with metaphyseal fixation. A prospective clinical Roentgen-Stereometry-Analysis (RSA) study]. Z Orthop Ihre Grenzgeb 2006; 144 (6): 587-93.
- Strom H, Mallmin H, Milbrink J, Petren-Mallmin M, Nivbrant B, Kolstad K. The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA. Acta Orthop Scand 2003; 74 (5): 525-30.
- Strom H, Kolstad K, Mallmin H, Sahlstedt B, Milbrink J. Comparison of the uncemented Cone and the cemented Bimetric hip prosthesis in young patients with osteoarthritis: an RSA, clinical and radiographic study. Acta Orthop Scand 2006; 77 (1): 71-8.
- Swierstra B A, Vervest A M, Walenkamp G H, et al. Dutch guideline on total hip prosthesis. Acta Orthop Scand 2011; 82 (5): 567-76.
- Tarasevicius S, Kesteris U, Robertsson O, Smailys A, Janusonis V, Wingstrand H. Introduction of total hip arthroplasty in Lithuania: results from the first 10 years. Acta Orthop Scand 2007; 78 (4): 454-7.
- Thanner J, Freij-Larsson C, Karrholm J, Malchau H, Wesslen B. Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties. Acta Orthop Scand 1995; 66 (3): 207-14.
- Thien T M, Ahnfelt L, Eriksson M, Stromberg C, Karrholm J. Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem - A prospective randomized comparison using radiostereometry. Acta Orthop Scand 2007; 78 (6): 730-8.
- Tonino A J, Rahmy A I. The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group. J Arthroplasty 2000; 15 (3): 274-82.
- Vochteloo A J, Pijls B G, van der Heide H J. Sutures v staples. Let’s add three other studies. BMJ 2010; 340: c2627.
- Volkmann R, Eingartner C, Winter E, Weise K, Weller S. Midterm results in 500 titanium alloy straight femoral stem prostheses-cemented and cementless technique. Eur J Ortho Surg Traumatol 1998; 8 (3): 133-9.
- von Schewelov T, Sanzen L, Onsten I, Carlsson A. Catastrophic failure of an uncemented acetabular component due to high wear and osteolysis - An analysis of 154 Omnifit prostheses with mean 6-year follow-up. Acta Orthop Scand 2004; 75 (3): 283-94.
- Weise K, Eingartner C, Winter E. [Cemented versus uncemented hip replacement--rational decision making using the BiCONTACT total hip system]. Zentralbl Chir 2003; 128 (1): 46-52.
- Williams H D, Browne G, Gie G A, Ling R S, Timperley A J, Wendover N A. The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips. J Bone Joint Surg Br 2002; 84 (3): 324-34.
- Wingstrand I, Persson B M, Wingstrand H. Total hip replacement with second generation cementing technique and the monobloc ScanHip: a 10-year follow-up. Int Orthop 2002; 26 (2): 69-71.
- Wykman A, Lundberg A. Subsidence of porous coated noncemented femoral components in total hip arthroplasty. A roentgen stereophotogrammetric analysis. J Arthroplasty 1992; 7 (2): 197-200.
- Wykman A, Selvik G, Goldie I. Subsidence of the femoral component in the noncemented total hip. A roentgen stereophotogrammetric analysis. Acta Orthop Scand 1988; 59 (6): 635-7.
- Wykman A, Olsson E, Axdorph G, Goldie I. Total hip arthroplasty. A comparison between cemented and press-fit noncemented fixation. J Arthroplasty 1991; 6 (1): 19-29.
- Yoo J J, Kim Y M, Yoon K S, Koo K H, Song W S, Kim H J. Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am 2005; 87 (3): 530-5.
- Young L, Duckett S, Dunn A. The use of the cemented Exeter Universal femoral stem in a District General Hospital: a minimum ten-year follow-up. J Bone Joint Surg Br 2009; 91 (2): 170-5.
Acta Orthopaedica
Volume 86, 2015 - Issue 5
Open access
2,069
Views
52
CrossRef citations to date
0
Altmetric
Original Articles
Early subsidence of shape-closed hip arthroplasty stems is associated with late revision
A systematic review and meta-analysis of 24 RSA studies and 56 survival studies
Paul van der VoortDepartment of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, LeidenCorrespondence[email protected]
, Bart G PijlsDepartment of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, LeidenCorrespondence[email protected]
, Marc J NieuwenhuijseDepartment of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, LeidenCorrespondence[email protected]
, Jorrit JasperDepartment of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, LeidenCorrespondence[email protected]
, Marta FioccoDepartment of Medical Statistics and Bioinformatics, Leiden University Medical Center, LeidenCorrespondence[email protected]
, Josepha W M PlevierWalaeus LibraryCorrespondence[email protected]
, Saskia MiddeldorpAcademic Medical Center, Department of Vascular Medicine, Amsterdam;Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the NetherlandsCorrespondence[email protected]
, Edward R ValstarDepartment of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden;Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, University of Technology, DelftCorrespondence[email protected]
& Rob G H H NelissenDepartment of Orthopaedics, Biomechanics and Imaging Group, Leiden University Medical Center, LeidenCorrespondence[email protected]
show all
Pages 575-585
|
Received 30 Jul 2014, Accepted 02 Mar 2015, Published online: 01 Sep 2015
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.