- Bishop N E, Burton A, Maheson M, Morlock M M. Biomechanics of short hip endoprostheses–the risk of bone failure increases with decreasing implant size. Clin Biomech (Bristol, Avon) 2010; 25 (7): 666–74.
- Brady O H, Garbuz D S, Masri B A, Duncan C P. The reliability and validity of the Vancouver classification of femoral fractures after hip replacement. J Arthroplasty 2000; 15 (1): 59–62.
- Brodén C, Mukka S, Muren O, Eisler T, Boden H, Stark A, et al. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem. Acta Orthop 2015; 86 (2): 169–74.
- Burston B J, Barnett A J, Amirfeyz R, Yates P J, Bannister G C. Clinical and radiological results of the collarless polished tapered stem at 15 years follow-up. J Bone Joint Surg Br 2012; 94 (7): 889–94.
- Chammout GK, Mukka SS, Carlsson T, Neander GF, Stark AW, Skoldenberg OG. Total hip replacement versus open reduction and internal fixation of displaced femoral neck fractures: a randomized long-term follow-up study. J Bone Joint Surg Am 2012 Nov 7;94(21):1921–8.
- Cook R E, Jenkins P J, Walmsley P J, Patton J T, Robinson C M. Risk factors for periprosthetic fractures of the hip: a survivorship analysis. Clin Orthop Relat Res 2008; 466 (7): 1652–6.
- Franklin J, Malchau H. Risk factors for periprosthetic femoral fracture. Injury 2007; 38 (6): 655–60.
- Garellick G, Malchau H, Herberts P. The Charnley versus the Spectron hip prosthesis: clinical evaluation of a randomized, prospective study of 2 different hip implants. J Arthroplasty 1999; 14 (4): 407–13.
- Garellick G K J, Lindahl H, Malchau H, Rogmark C, Rolfson O. Annual report from the Swedish Hip Arthroplasty Register. 2013. 2014; 196. http://www.shpr.se/sv/Publications/DocumentsReports.aspx. Accessed 3 November 2015.
- Garellick G K J, Lindahl H, Malchau H, Rogmark C, Rolfson O. Annual report from the Swedish Hip Arthroplasty Register. 2014. 2015. http://www.shpr.se/sv/Publications/DocumentsReports.aspx. Accessed 3 November 2015.
- Ginsel B L, Morishima T, Wilson L J, Whitehouse S L, Crawford R W. Can larger-bodied cemented femoral components reduce periprosthetic fractures? A biomechanical study. Arch Orthop Trauma Surg. 2015; 135(4): 517–22.
- Hank C, Schneider M, Achary C S, Smith L, Breusch S J. Anatomic stem design reduces risk of thin cement mantles in primary hip replacement. Arch Orthop Trauma Surg 2010; 130 (1): 17–22
- Hedbeck C J, Enocson A, Lapidus G, Blomfeldt R, Tornkvist H, Ponzer S, Tidermark J. Comparison of bipolar hemiarthroplasty with total hip arthroplasty for displaced femoral neck fractures: a concise four-year follow-up of a randomized trial. J Bone Joint Surg Am 2011; 93: 445–50.
- Inngul C, Enocson A. Postoperative periprosthetic fractures in patients with an Exeter stem due to a femoral neck fracture: cumulative incidence and surgical outcome. Int Orthop 2015; 39(9): 1683–8.
- Johansson T. Internal fixation compared with total hip replacement for displaced femoral neck fractures: a minimum fifteen-year follow-up study of a previously reported randomized trial. J Bone Joint Surg Am 2014; 96: e46.
- Leonardsson O, Sernbo I, Carlsson A, Akesson K, Rogmark C. Long-term follow-up of replacement compared with internal fixation for displaced femoral neck fractures: results at ten years in a randomised study of 450 patients. J Bone Joint Surg Br 2010; 92(3): 406–12. Erratum in: J Bone Joint Surg Br.
- Lindahl H, Malchau H, Herberts P, Garellick G. Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the Swedish National Hip Arthroplasty Register. J Arthroplasty 2005; 20 (7): 857–65.
- Lindahl H, Garellick G, Regner H, Herberts P, Malchau H. Three hundred and twenty-one periprosthetic femoral fractures. J Bone Joint Surg Am 2006a; 88 (6): 1215–22.
- Lindahl H, Malchau H, Oden A, Garellick G. Risk factors for failure after treatment of a periprosthetic fracture of the femur. J Bone Joint Surg Br 2006b; 88 (1): 26–30.
- Lindahl H, Oden A, Garellick G, Malchau H. The excess mortality due to periprosthetic femur fracture. A study from the Swedish national hip arthroplasty register. Bone 2007; 40 (5): 1294–8.
- Macpherson G J, Hank C, Schneider M, Trayner M, Elton R, Howie C R, et al. The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design. Acta Orthop 2010; 81 (3): 292–5
- Morishima T, Ginsel B L, Choy G G, Wilson L J, Whitehouse S L, Crawford R W. Periprosthetic fracture torque for short versus standard cemented hip stems: an experimental in vitro study. J Arthroplasty 2014; 29(5): 1067–71.
- Phillips J R, Moran C G, Manktelow A R. Periprosthetic fractures around hemiarthroplasty performed for hip fracture. Injury 2013; 44(6): 757–62.
- Raut S, Parker M J. Medium to long term follow up of a consecutive series of 604 Exeter Trauma Stem Hemiarthroplasties (ETS) for the treatment of displaced intracapsular femoral neck fractures. Injury 2015 Nov 10. pii: S0020-1383(15)00696-8. doi: 10.1016/j.injury.2015.10.077. [Epub ahead of print].
- Sarvilinna R, Huhtala H S, Sovelius R T, Halonen P J, Nevalainen J K, Pajamaki K J. Factors predisposing to periprosthetic fracture after hip arthroplasty: a case (n = 31)-control study. Acta Orthop Scand 2004; 75 (1): 16–20.
- Shields E, Behrend C, Bair J, Cram P, Kates S. Mortality and financial burden of periprosthetic fractures of the femur. Geriatr Orthop Surg Rehabil 2014; 5 (4): 147–53.
- Thien T M, Chatziagorou G, Garellick G, Furnes O, Havelin L I, Makela K, et al. Periprosthetic femoral fracture within two years after total hip replacement: analysis of 437,629 operations in the nordic arthroplasty register association database. J Bone Joint Surg Am 2014; 96 (19): e167.
- Yates P J, Burston B J, Whitley E, Bannister G C. Collarless polished tapered stem: clinical and radiological results at a minimum of ten years’ follow-up. J Bone Joint Surg Br 2008; 90 (1): 16–22.
Acta Orthopaedica
Volume 87, 2016 - Issue 3
Open access
1,901
Views
29
CrossRef citations to date
0
Altmetric
Original Articles
Substantially higher prevalence of postoperative periprosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem
Sebastian MukkaDepartment of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;; Correspondence[email protected]
, Carl MellnerDepartment of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;;
, Björn KnutssonDepartment of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;; ;Department of Surgical Sciences, Section of Orthopedics, Uppsala University, Uppsala;
, Arkan Sayed-NoorDepartment of Orthopedics, Sundsvall Hospital, Sundsvall, and Department of Surgical and Perioperative Sciences, Umeå University, Umeå;;
& Olof SköldenbergDepartment of Orthopedics, Danderyd Hospital and Karolinska Institutet, Stockholm, and Department of Clinical Sciences, Danderyd Hospital, Stockholm, Sweden
Pages 257-261
|
Received 12 Nov 2015, Accepted 08 Feb 2016, Published online: 04 Apr 2016
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.