References
- Ahnfelt L. Re-opererade totala höftledsplastiker i Sverige under åren 1979–1983. (In Swedish). Thesis, University of Göteborg, GöteborgSweden 1987
- Alho A, Søreide O, Bjersand A J. Mechanical factors in loosening of Christiansen and Chamley arthroplasties. Acta Orthop Scand 1984; 55(3)261–6
- Andersson G BJ, Freeman M AR, Swanson S AV. Loosening of the cemented acetabularrup in total hip replacement. J Bone Joint Surg (Br) 1972; 54(4)590–9
- Dumbleton J. H. Tribology of natural and artificial joints. Elsevier, Amsterdam 1981
- Eiken O, Ekerot L, Lindström C, Jonsson K. Silicone carpal implants: risk or benefit?. Scand J Plast Reconstr Surg 1985; 19(3)295–304
- Forest M, Courpied J P, Lefloch P, Carlioz A, Abelanet R, Postel M. La hanche operee: reactions tissulaires locales. Ann Pathol 1985; 5(1)3–18
- Havelin L I, Gjerdet N R, Lunde O D, Rait M, Sudmann E. Wear of the Christiansen hip prosthesis. Acta Orthop Scand 1986; 57(5)419–22
- Heilmann K, Diezel P B, Rossner J A, Brinkman K A. Morphological studies in tissues surrounding alloarthroplastic joints. Virchows Arch (Pathol Anat) 1975; 366(2)93–106
- Howie D W, Vemon-Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement bone interface in the presence of polyethylene wear particles. J Bone Joint Surg (Am) 1988; 70(2)257–63
- Johanson N A, Callaghan J J, Salvati E A, Merkow R L. 14 year follow-up study of a patient with massive calcar resorption. A case report. Clin Orthop 1986; 189–96, (213)
- Josefsson G, Eriksson B, Fagerlund M, Gudmundsson G, Helgasson H, Nordstrom B, Olnäs B-O, Söderberg L, Wijkström S. Prohylaxis in total hip arthroplasty. A prospective, comparative study of 1,690 operations. Acta Orthop Scand 1980; 51: 383
- Kamme C, Lindberg L. Aerobic and anaerobic bacteria in deep infections after total hip arthroplasty: differential diagnosis between infectious and non-infectious loosening. Clin Orthop 1981; 201–7, 154
- Mathiesen E B, Lindgren U, Reinholt F P, Sudmann E. Wear of the acetabular socket. Comparison of polyacetal and polyethylene. Acta Orthop Scand 1986; 57(3)193–6
- Mirra J M, Marder R A, Amstutz H C. The pathology of failed total joint arthroplasty. Clin Orthop 1982; 175–83, 170
- Mittelmeier H, Singer L. Anatomische und histologische Untersuchungen von Arthroplastikgelenken mit Plexiglas Endoprothesen. Arch Orthop Unfall Chir 1956; 48: 519–60
- Ohlin A, Alffram P A, Olnäs B O. Beror Christiansen lossningar på plastmaterialet Delrin? (Abstract in Swedish). Svenska Läkarsällskapets Handlingar Hygiea 1982; 91(6)223
- Pazzaglia U E, Ceciliani L, Wilkinson M J, Dell Orbo C. Involvement of metal particles in loosening of metal plastic total hip prostheses. Arch Orthop Trauma Surg 1985; 104(3)164–74
- Persson P G, Ohlin A. A histological study of Christiansen total hip. (Abstract). Acta Orthop Scand 1986; 57(3)268
- Revell P A, Weightman B, Freeman M A, Roberts B V. The production and biology of polyethylene wear debris. Arch Orthop Trauma Surg 1978; 91(3)167–81
- Sudmann E, Havelin L I, Lunde O D, Rait M. The Chamley versus the Christiansen total hip arthroplasty. A comparative clinical study. Acta Orthop Scand 1983; 54(4)545–52
- Sundal B, Kavlie H, Christiansen T. Total hip replacement with a new trunnion bearing prosthesis (the Christiansen prosthesis). A report on the prosthesis and the early results. Acta Chir Scand 1974; 140(3)189–93
- Volz R G, Wilson R J. Factors affecting the mechanical stability of the cemented acetabular component in total hip replacement. J Bone Joint Surg (Am) 1977; 59(4)501–4
- Webb P J, Wright K W, Winter G D. The Monk “soft top” endoprosthesis. Clinical, biomechanical and histopathological observations. J Bone Joint Surg (Br) 1980; 62(2)174–9
- Willert H G, Semlitsch M. Reaction of the articular capsule to plastic and metallic wear products for joint endoprotheses. Sulzer Tech Rev 1975; 2: 119–33
- Wroblewski B. M. Wear of high density polyethylene on bone and cartilage. J Bone Joint Surg (Br) 1979; 61(4)498–500