References
- Andriacchi T P., Stanwyck T S., Galante J O. Knee biomechanics and total knee replacement. J Arthroplasty 1986; 1(3)211–9
- Andriacchi T P., Galante J O. Retention of the posterior cruciate in total knee arthroplasty. J Arthroplasty (Suppl) 1988; 3: SI3–9
- Bartel D L., Bicknell V L., Wright T M. The effect of conformity, thickness, and material on stresses in ultra high molecular weight components for total joint replacement. J Bone Joint Surg (Am) 1986; 68(7)1041–51
- Connelly G M., Rimnac C M., Wright T M., Hertzberg R W., Manson J A. Fatigue crack propagation behavior of ultrahigh molecular weight polyethylene. J Orthop Res 1984; 2(2)119–25
- Dannenmaier W C., Haynes D W., Nelson C L. Granulomatous reaction and cystic bony destruction associated with high wear rate in a total knee prosthesis. Clin Orthop 1985; 198: 224–30
- Engh G A. Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report. J Bone Joint Surg (Am) 1988; 70(7)1093–6
- Hood R W., Wright T M., Burstein A H. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res 1983; 17(5)829–42
- Insall J N., Ranawat C S., Aglietti P, Shine J. A comparison of four models of total knee replacement prostheses. J Bone Joint Surg (Am) 1976; 58(6)754–65
- Kilgus D J., Moreland J R., Finerman G, Funahashi T T. Catastrophic wear of tibial polyethylene inserts. Presented at the Knee Society Meeting, AnaheimUSA, March, 1991
- Landy M M., Walker P S. Wear of ultra high molecular weight polyethylene components of 90 retrieved knee prostheses. J Arthroplasty (Suppl) 1988; 3: S73–85
- Lindstrand A, Ryd L, Stenstrom A. Polyethylene failure in two total knees. Wear of thin, metal backed PCA tibial components. Acta Orthop Scand 1990; 61(6)575–7
- Pizzoferrato A. Evaluation of the tissue response to the wear products of the hip joint endo arthroprosthesis. Biomater Med Devices Artif Organs 1979; 7(2)257–62
- Rose R M., Crugnola A, Ries M, Cimino W R., Paul I, Radin E L. On the origins of high in vivo wear rates in polyethylene components of total joint prostheses. Clin Orthop 1979; 145: 277–86
- Rose R M., Nusbaum H J., Schneider H, Ries M, Paul I, Crugnola A, Simon S R., Radin E L. On the true wear rate of ultra high molecular weight polyethylene in the total hip prosthesis. J Bone Joint Surg (Am) 1980; 62(4)537–49
- Rose R M., Ries M D., Paul I L., Crugnola A M., Ellis E. The true wear rate of ultra high molecular weight olyethylene in the total knee prosthesis. J Biomed Mater Res 1984; 18(2)207–224
- Rostoker W, Galante J O. Contact pressure dependence of wear rates of ultra high molecular weight polyethylene. J Biomed Mater Res 1979; 13(6)957–64
- Soudry M, Walker P S., Reilly D T., Kurosawa H, Sledge C B. Effects of total knee replacement design on femoral tibial contact conditions. J Arthroplasty 1986; 1(1)35–45
- Tsao A, McCrae C R., Mintz L, Stulberg S D. Arthroscopic evaluation of high density polyethylene wear in total knee replacements. Presented at the Knee Society Meeting, AnaheimUSA, March, 1991
- Uchida S, Yoshino S, Doi M, Kudo H. Side effects of prosthetic materials on the human body. Int Orthop 1980; 3(4)285–91
- Walker P S., Ben Dov M, Askew M J., Pugh J. The deformation and wear of plastic components in artificial knee joints. Engin Med 1981; 10: 33
- Wright T M., Bartel D L. The problem of surface damage in polyethylene total knee components. Clin Orthop 1986; 205: 67–74
- Wright T M., Astion D J., Bansal M, Rimnac C M., Green T, Insall J N., Robinson R P. Failure of carbon fiber reinforced polyethylene total knee replacement components. A report of two cases. J Bone Joint Surg (Am) 1988; 70(6)926–32
- Wright T M., Rimnac C M., Faris P M., Bansal M. Analysis of surface damage in retrieved carbon fiber reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements. J Bone Joint Surg (Am) 1988; 70(9)1312–9