References
- Askew M J, Steege J W, Lewis J L, Ranieri J R, Wixson R L. Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 1984; 1(4)412–20
- Bannister G C, Miles A W. The influence of cementing technique and blood on the strength of the bone‐cement interface. Engineering Med 1988; 17(3)131–3
- Benjamin J B, Gie G A, Lee A J C, Ling R S M, Volz R G. Cementing technique and the effects of bleeding. J Bone Joint Surg (Br) 1987; 69(4)620–4
- Charnley J. Low friction arthroplasty of the hip. Theory and practice. Springer Verlag, Berlin 1979
- Eftekhar N S, Nercessian O. Incidence and mechanism of failure of cemented acetabular component in total hip arthroplasty. Orthop Clin N Am 1988; 19(3)557–66
- Garcia‐Cimbrelo E, Munuera L. Early and late loosening of the acetabular cup after low‐friction arthroplasty. J Bone Joint Surg (Am) 1992; 74(8)1119–29
- Gruen T A, Markolf K L, Amstutz H C. Effects of lamination and blood entrapment on the strength of acrylic bone cement. Clin Orthop 1976; 119: 250–5
- Holm N J. The modulus of elasticity and flexural strength of some acrylic bone cements. Acta Orthop Scand 1977; 48: 436–42
- Huiskes R, Sloof T J. Thermal injury of cancellous bone, following pressurized penetration of acrylic cement. Trans Orthop Res Soc 1981; 6: 134
- Juliusson R, Arve J, Ryd L. Cementation pressure in arthroplasty. In vitro study of cement penetration into femoral heads. Acta Orthop Scand 1994; 65(2)131–4
- Juliusson R, Flivik G, Nilsson J, Ryd L, Önnerfält R. Circulating blood diminishes cement penetration into cancellous bone. In vivo studies of 21 arthrotic femoral heads. Acta Orthop Scand 1995; 66(3)234–8
- Krause W R, Krug W, Eng B, Miller J. Strength of the cement‐bone interface. Clin Orthop 1982; 163: 290–9
- Lee A J C, Ling R S M, Vangala S S. Some clinically relevant variables affecting the mechanical behavior of bone cement. Arch Orthop Trauma Surg 1978; 92: 1–18
- MacDonald W, Swarts E, Beaver R. Penetration and shear strength of cement‐bone interfaces In vivo. Clin Orthop 1993; 286: 283–8
- Majkowski R S, Miles A W, Bannister G C, Perkins J, Taylor G J S. Bone surface preparation in cemented joint replacement. J Bone Joint Surg (Br) 1993; 75(3)459–63
- Majkowski R S, Bannister G C, Miles A W. The effect of bleeding on the cement‐bone interface. An experimental study. Clin Orthop 1994; 299: 293–7
- Malchau H, Herberts P, Ahnfelt L. Prognosis of total hip replacements in Sweden. Follow‐up of 92,675 operations performed 1978–1990. Acta Orthop Scand 1993; 64(5)497–506
- Mulroy W F, Estok D M, Harris W H. Total hip arthroplasty with use of so‐called second‐generation cementing techniques. A fifteen‐year‐average follow‐up study. J Bone Joint Surg (Am) 1995; 77(12)1845–52
- Noble P, Swarts E. Penetration of acrylic bone cements into cancellous bone. Acta Orthop Scand 1983; 54: 566–73
- Ranawat C S, Deshmukh R G, Peters L E, Umlas M E. Prediction of the long‐term durability of all‐polyethylene cemented sockets. Clin Orthop 1995; 317: 89–105
- Rey R M, Paiement G D, McGann W M, Jasty M, Harrigan T P, Burke D W, Harris W H. A study of intrusion characteristics of low‐viscosity cement Simplex‐P and Palacos cements in a bovine cancellous bone model. Clin Orthop 1987; 215: 272–8
- Saha S, Pal S. Mechanical properties of bone cement: A review. J Biomed Mater Res 1984; 18: 435–62
- Schmalzried T P, Kwong L M, Jastu M, Sedlacek R C, Haire T C, O'Connor D O, Bragdon C R, Kabo J M, Malcom A J, Harris W H. The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Clin Orthop 1992; 274: 60–78