199
Views
15
CrossRef citations to date
0
Altmetric
Original Article

Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipients of the Nucleus CI24RE device

, , , , , , , , , , , , & show all
Pages 775-787 | Received 10 Mar 2009, Accepted 06 May 2010, Published online: 29 Jul 2010

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (7)

Oliver C. Dziemba, Aristotelis Aristeidou & Stefan Brill. (2021) Slope of electrically evoked compound action potential amplitude growth function is site-dependent. Cochlear Implants International 22:3, pages 136-147.
Read now
Tim Liebscher, Katrin Alberter & Ulrich Hoppe. (2018) Cortical auditory evoked potentials in cochlear implant listeners via single electrode stimulation in relation to speech perception. International Journal of Audiology 57:12, pages 939-946.
Read now
Femke L. Theelen - van den Hoek, Monique Boymans & Wouter A. Dreschler. (2015) Spectral loudness summation for electrical stimulation in cochlear implant users. International Journal of Audiology 54:11, pages 818-827.
Read now
Ralf Greisiger, Jon K. Shallop, Per Kristian Hol, Ole Jakob Elle & Greg Eigner Jablonski. (2015) Cochlear implantees: Analysis of behavioral and objective measures for a clinical population of various age groups. Cochlear Implants International 16:sup4, pages 1-19.
Read now
Alicia Huarte, Angel Ramos, Constantino Morera, Luis Garcia-Ibáñez, Rolf Battmer, Norbert Dillier, Thomas Wesarg, Joachim Müller-Deile, Mattias Hey, Erwin Offeciers, Ernst von Wallenberg, Chrystelle Coudert & Matthijs Killian. (2014) Evaluation of neural response telemetry (NRT™) with focus on long-term rate adaptation over a wide range of stimulation rates. Cochlear Implants International 15:3, pages 136-144.
Read now
Andrew Botros, Rami Banna & Saji Maruthurkkara. (2013) The next generation of Nucleus® fitting: A multiplatform approach towards universal cochlear implant management. International Journal of Audiology 52:7, pages 485-494.
Read now
Rolf-Dieter Battmer, Norbert Dillier, Wai Kong Lai, Klaus Begall, Elisabeth Estrada Leypon, Juan C. Falcón González, Manuel Manrique, Constantino Morera, Joachim Müller-Deile, Thomas Wesarg, Andrzej Zarowski, Matthijs J. Killian, Ernst von Wallenberg & Guido F. Smoorenburg. (2010) Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus® CI24RE device: Relation to perceptual threshold and loudness comfort profiles. International Journal of Audiology 49:9, pages 657-666.
Read now

Articles from other publishers (8)

Ursina Rüegg, Adrian Dalbert, Dorothe Veraguth, Christof Röösli, Alexander Huber & Flurin Pfiffner. (2021) Correlation between Speech Perception Outcomes after Cochlear Implantation and Postoperative Acoustic and Electric Hearing Thresholds. Journal of Clinical Medicine 10:2, pages 324.
Crossref
Johan J. de Vos, Jan Dirk Biesheuvel, Jeroen J. Briaire, Pieter S. Boot, Margriet J. van Gendt, Olaf M. Dekkers, Marta Fiocco & Johan H. M. Frijns. (2018) Use of Electrically Evoked Compound Action Potentials for Cochlear Implant Fitting: A Systematic Review. Ear & Hearing 39:3, pages 401-411.
Crossref
Oliver C. Dziemba, Thomas Hocke, Alexander Müller & Holger Kaftan. (2018) Excitation characteristic of a bipolar stimulus for broadband stimulation in measurements of electrically evoked auditory potentials. Zeitschrift für Medizinische Physik 28:1, pages 73-77.
Crossref
Feddo B. van der Beek, Jeroen J. Briaire, Kim S. van der Marel, Berit M. Verbist & Johan H.M. Frijns. (2016) Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn. Audiology and Neurotology 21:1, pages 54-67.
Crossref
Feddo B. van der Beek, Jeroen J. Briaire & Johan H.M. Frijns. (2015) Population-Based Prediction of Fitting Levels for Individual Cochlear Implant Recipients. Audiology and Neurotology 20:1, pages 1-16.
Crossref
Frederic Venail, Thibault Mura, Mohamed Akkari, Caroline Mathiolon, Sophie Menjot de Champfleur, Jean Pierre Piron, Marielle Sicard, Françoise Sterkers-Artieres, Michel Mondain & Alain Uziel. (2015) Modeling of Auditory Neuron Response Thresholds with Cochlear Implants. BioMed Research International 2015, pages 1-10.
Crossref
Pieter J. Venter & Johan J. Hanekom. (2014) Is There a Fundamental 300 Hz Limit to Pulse Rate Discrimination in Cochlear Implants?. Journal of the Association for Research in Otolaryngology 15:5, pages 849-866.
Crossref
Fei Ji, Ke Liu & Shi-ming Yang. (2014) Clinical application of electrically evoked compound action potentials. Journal of Otology 9:3, pages 117-121.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.