870
Views
6
CrossRef citations to date
0
Altmetric
Biomedical paper

Robot-assisted thoracoscopic brachytherapy for lung cancer: Comparison of the ZEUS robot, VATS, and manual seed implantation

, , , , , , & , MD, MSc show all
Pages 270-277 | Received 08 Jan 2007, Accepted 15 Jul 2007, Published online: 06 Jan 2010

References

  • Parkin DM, Pisani P, Ferlay J. Estimates of the worldwide incidence of 25 major cancers in 1990. Int J Cancer 1999; 80(6)827–841
  • Martinez-Monge R, Garran C, Vivas I, Lopez-Picazo JM. Percutaneous CT-guided 103Pd implantation for the medically inoperable patient with T1N0M0 non-small cell lung cancer: A case report. Brachytherapy 2004; 3(3)179–181
  • Brach B, Buhler C, Hayman MH, Joyner LRJ, Liprie SF. Percutaneous computed tomography-guided fine needle brachytherapy of pulmonary malignancies. Chest 1994; 106(1)268–274
  • Imamura F, Chatani M, Nakayama T, Uda H, Nakamura S, Horai T. Percutaneous brachytherapy for small-sized non-small cell lung cancer. Lung Cancer 1999; 24(3)169–174
  • Ricke J, Wust P, Wieners G, Hengst S, Pech M, Lopez HE, Felix R. CT-guided interstitial single-fraction brachytherapy of lung tumors: Phase I results of a novel technique. Chest 2005; 127(6)2237–2242
  • Hilaris BS, Martini N. The current state of intraoperative interstitial brachytherapy in lung cancer. Int J Radiat Oncol Biol Phys 1988; 15(6)1347–1354
  • Fleischman EH, Kagan AR, Streeter OE, Tyrell J, Wollin M, Leagre CA. Harvey JC. Iodine125 interstitial brachytherapy in the treatment of carcinoma of the lung. J Surg Oncol 1992; 49(1)25–28
  • Tomberlin JK, Halperin EC, Kusin P, Leopold K, Bentel G, George S, Powers M, Wolfe W. Endobronchial interstitial Au-198 implantation in the treatment of recurrent bronchogenic carcinoma. J Surg Oncol 1992; 49(4)213–219
  • Buckingham RA, Buckingham RO. Robots in operating theatres. BMJ 1995; 311(7018)1479–1482
  • Munz Y, Moorthy K, Dosis A, Hernandez JD, Bann S, Bello F, Martin S, Darzi A, Rockall T. The benefits of stereoscopic vision in robotic-assisted performance on bench models. Surg Endosc 2004; 18(4)611–616
  • Corcione F, Esposito C, Cuccurullo D, Settembre A, Miranda N, Amato F, Pirozzi F, Caiazzo P. Advantages and limits of robot-assisted laparoscopic surgery: Preliminary experience. Surg Endosc 2005; 19(1)117–119
  • d'Amato TA, Galloway M, Szydlowski G, Chen A, Landreneau RJ. Intraoperative brachytherapy following thoracoscopic wedge resection of stage I lung cancer. Chest 1998; 114(4)1112–1115
  • Fernando HC, Santos RS, Benfield JR, Grannis FW, Keenan RJ, Luketich JD, Close JM, Landreneau RJ. Lobar and sublobar resection with and without brachytherapy for small stage IA non-small cell lung cancer. J Thoracic Cardiovascular Surg 2005;129(2):261–267.
  • Lee W, Daly BD, DiPetrillo TA, Morelli DM, Neuschatz AC, Morr J, Rivard MJ. Limited resection for non-small cell lung cancer: Observed local control with implantation of I-125 brachytherapy seeds. Ann Thoracic Surg 2003; 75(1)237–242
  • Pisch J, Belsley SJ, Ashton R, Wang L, Woode R, Connery C. Placement of 125I implants with the da Vinci robotic system after video-assisted thoracoscopic wedge resection: A feasibility study. Int J Radiat Oncol Biol Phys 11-1-2004;60(3):928–932.
  • Birdas TJ, Koehler RP, Colonias A, Trombetta M, Maley RH, Jr, Landreneau RJ, Keenan RJ. Sublobar resection with brachytherapy versus lobectomy for stage Ib nonsmall cell lung cancer. Ann Thoracic Surg 2006; 81(2)434–438
  • Chen A, Galloway M, Landreneau R, d'Amato T, Colonias A, Karlovits S, Quinn A, Santucci T, Kalnicki S, Brown D. Intraoperative 125I brachytherapy for high-risk stage I non-small cell lung carcinoma. Int J Radiat Oncol Biol Phys 1999; 44(5)1057–1063
  • American College of Surgeons Oncology Group. Z4032 study: A randomized Phase III study of sublobar resection versus sublobar resection plus brachytherapy in high risk patients with non-small cell lung cancer (NSCLC), 3 cm or smaller. https://www.acosog.org/studies/organ_site/thoracic/index.jsp.
  • Hornblower VD, Yu E, Fenster A, Battista JJ, Malthaner RA. 3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours. Phys Med Biol 2007; 52(1)91–106
  • Trejos AL, Patel RV, Malthaner RA. A device for robot-assisted minimally-invasive lung brachytherapy. Proceedings of the 2006 IEEE International Conference on Robotics and Automation, Orlando, FL, May 2006. pp 4187–4192.
  • Trejos AL, Aaronson NK, Lin AW, Pytel MP, Patel RV, Malthaner RA. Robot-assisted minimally invasive lung brachytherapy. Int J Med Robotics Comput Assist Surg 2007; 3: 44–55
  • Rasband W, National Institute of Mental Health. ImageJ. http://rsb.info.nih.gov/ij/docs/index.html.
  • Rosner, B, editor. Fundamentals of Biostatistics. 5th edition. Pacific Grove, CA: Duxbury Press; 2000.
  • Hoskins MW. Brachytherapy instrument and methods. US Patent Number 6,752,753.
  • Wei Z, Gardi L, Downey DB, Fenster A. Automated localization of implanted seeds in 3D TRUS images used for prostate brachytherapy. Med Phys 2006; 33(7)2404–2417
  • Wei Z, Ding M, Downey D, Fenster A. 3D TRUS guided robot assisted prostate brachytherapy. In: Duncan JS, Gerig G, editors. Proceedings of 8th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2005), Palm Springs, CA, October 2005. Part II. Lecture Notes in Computer Science 3750. Berlin: Springer; 2005. pp 17–24.
  • Wei Z, Wan G, Gardi L, Mills G, Downey D, Fenster A. Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation. Med Phys 2004; 31(3)539–548
  • Stoianovici D, Cadeddu JA, Demaree RD, Basile SA, Taylor RH, Whitcomb LL, Sharpe WN Jr, Kavoussi LR. A novel mechanical transmission applied to percutaneous renal access. Proceedings of ASME Dynamic Systems and Control Division 1997;DSC-61:401–406.
  • Cleary K, Freedman M, Clifford M, Lindisch D, Onda S, Jiang L. Image-guided robotic delivery system for precise placement of therapeutic agents. J Control Release 2001; 74(1–3)363–368
  • Yanof J, Bauer C, Wood B. Tactile feedback and display system for CT-guided, robot-assisted percutaneous procedures. In: Lemke HU, Vannier MW, Inamura K, Farman AG, Doi K, Reiber DHC, editors. Computer Assisted Radiology and Surgery. Proceedings of the 18th International Congress and Exhibition (CARS 2004), Chicago, IL, June 2004. Amsterdam: Elsevier; 2004. pp 521–526.
  • Hong J, Dohi T, Hashizume M, Konishi K, Hata N. An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy. Phys Med Biol 2004; 49(3)441–455

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.