885
Views
20
CrossRef citations to date
0
Altmetric
Original Article

Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC

, , &
Pages 1432-1437 | Received 20 May 2008, Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (5)

Tine B. Nielsen, Olfred Hansen, Tine Schytte & Carsten Brink. (2014) Four-dimensional dose evaluation of inhomogeneous dose distributions planned for non-small cell lung cancer patients with lymph node involvement. Acta Oncologica 53:5, pages 707-712.
Read now
Karina L. Gottlieb, Christian R. Hansen, Olfred Hansen, Jonas Westberg & Carsten Brink. (2010) Investigation of respiration induced intra- and inter-fractional tumour motion using a standard Cone Beam CT. Acta Oncologica 49:7, pages 1192-1198.
Read now
Per R. Poulsen, Byungchul Cho, Amit Sawant, Dan Ruan & Paul J. Keall. (2010) Dynamic MLC tracking of moving targets with a single kV imager for 3D conformal and IMRT treatments. Acta Oncologica 49:7, pages 1092-1100.
Read now
Ludvig Paul Muren, Jørgen B. Petersen, Jolanta Hansen & Rune Hafslund. (2009) Medical physics in the Nordic countries: The past, the present and the future. Acta Oncologica 48:2, pages 165-168.
Read now
Cai Grau, Ludvig Paul Muren, Morten Høyer, Jacob Lindegaard & Jens Overgaard. (2008) Image-guided adaptive radiotherapy – integration of biology and technology to improve clinical outcome. Acta Oncologica 47:7, pages 1182-1185.
Read now

Articles from other publishers (15)

Gang Liu, Lewei Zhao, Peilin Liu, Di Yan, Rohan Deraniyagala, Craig Stevens, Xiaoqiang Li & Xuanfeng Ding. (2023) Development of a standalone delivery sequence model for proton arc therapy. Medical Physics.
Crossref
Bin Han, Bian Wu, Fala Hu, Yangguang Ma, Haiyang Wang, Xinwei Han, Gang Liu & Yuexin Guo. (2022) Simulation of dosimetric consequences of intrafraction variation of tumor drift in lung cancer stereotactic body radiotherapy. Frontiers in Oncology 12.
Crossref
Kiyoshi Yoda. (2017) A Radiotherapy Treatment Margin Formula When Systematic Positioning Errors are Relatively Small Compared to Random Positioning Errors: A First-Order Approximation. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 06:02, pages 193-196.
Crossref
Mauro Loi & J.J. Nuyttens. 2018. Alternate Fractionation in Radiotherapy. Alternate Fractionation in Radiotherapy 157 172 .
M. Rico, E. Martínez, S. Pellejero, B. Bermejo, P. Navarrete, M. Barrado, M. Campo, F. Mañeru, E. Villafranca & J. Aristu. (2016) Influence of different treatment techniques and clinical factors over the intrafraction variation on lung stereotactic body radiotherapy. Clinical and Translational Oncology 18:10, pages 1011-1018.
Crossref
Tine Bjørn Nielsen, Christian Rønn Hansen, Jonas Westberg, Olfred Hansen & Carsten Brink. (2015) Impact of 4D image quality on the accuracy of target definition. Australasian Physical & Engineering Sciences in Medicine 39:1, pages 103-112.
Crossref
Martina Descovich, Christopher McGuinness, Danita Kannarunimit, Josephine Chen, Dilini Pinnaduwage, Jean Pouliot, Norbert Kased, Alexander R. Gottschalk & Sue S. Yom. (2015) Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: Insights from lung tumor patients treated with robotic radiosurgery. Medical Physics 42:3, pages 1280-1287.
Crossref
Joost J. Nuyttens. 2015. Stereotactic Body Radiotherapy. Stereotactic Body Radiotherapy 127 148 .
B. Zhao & J. Dai. (2014) Determining leaf trajectories for dynamic multileaf collimators with consideration of marker visibility: an algorithm study. Journal of Radiation Research 55:5, pages 976-987.
Crossref
Keisuke Usui, Yasunobu Ichimaru, Yasuhiro Okumura, Katsuki Murakami, Makoto Seo, Etsuo Kunieda & Koichi Ogawa. (2012) Dose calculation with a cone beam CT image in image-guided radiation therapy. Radiological Physics and Technology 6:1, pages 107-114.
Crossref
Chirag Shah, Inga S. Grills, Larry L. Kestin, Samuel McGrath, Hong Ye, Shannon K. Martin & Di Yan. (2012) Intrafraction Variation of Mean Tumor Position During Image-Guided Hypofractionated Stereotactic Body Radiotherapy for Lung Cancer. International Journal of Radiation Oncology*Biology*Physics 82:5, pages 1636-1641.
Crossref
Tine B. Nielsen, Vibeke N. Hansen, Jonas Westberg, Olfred Hansen & Carsten Brink. (2012) A dual centre study of setup accuracy for thoracic patients based on Cone-Beam CT data. Radiotherapy and Oncology 102:2, pages 281-286.
Crossref
Gitte Fredberg Persson, Ditte Eklund Nygaard, Carsten Brink, Jonas Westberg Jahn, Per Munck af Rosenschöld, Lena Specht & Stine Sofia Korreman. (2010) Deviations in delineated GTV caused by artefacts in 4DCT. Radiotherapy and Oncology 96:1, pages 61-66.
Crossref
Kiyotomo Matsugi, Yuichiro Narita, Akira Sawada, Mitsuhiro Nakamura, Yuki Miyabe, Yukinori Matsuo, Masaru Narabayashi, Yoshiki Norihisa, Takashi Mizowaki & Masahiro Hiraoka. (2009) Measurement of Interfraction Variations in Position and Size of Target Volumes in Stereotactic Body Radiotherapy for Lung Cancer. International Journal of Radiation Oncology*Biology*Physics 75:2, pages 543-548.
Crossref
Anne Richter, Qiaoqiao Hu, Doreen Steglich, Kurt Baier, Jürgen Wilbert, Matthias Guckenberger & Michael Flentje. (2008) Investigation of the usability of conebeam CT data sets for dose calculation. Radiation Oncology 3:1.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.