489
Views
45
CrossRef citations to date
0
Altmetric
Original Article

Surgical Navigation Based on Fluoroscopy—Clinical Application for Computer-Assisted Distal Locking of Intramedullary Implants

, , , &
Pages 391-400 | Received 27 Dec 1999, Accepted 25 Sep 2000, Published online: 06 Jan 2010

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (7)

Abdulaziz Al-Ahaideb, Andrew Quinn, Erin Smith, Jeffrey Yach, Randy Ellis & David Pichora. (2009) Computer assisted LISS plate placement: an in vitro study. Computer Aided Surgery 14:4-6, pages 123-126.
Read now
M.-Y. Lee, C. H. Kuo & S.-S. Hung. (2008) A new fluoroscopy-free navigation device for distal interlocking screw placement. Journal of Medical Engineering & Technology 32:4, pages 284-295.
Read now
Guoyan Zheng, Xuan Zhang, Daniel Haschtmann, Philippe Gédet, Frank Langlotz & Lutz P. Nolte. (2007) Accurate and reliable pose recovery of distal locking holes in computer-assisted intra-medullary nailing of femoral shaft fractures: A preliminary study. Computer Aided Surgery 12:3, pages 138-151.
Read now
Paul Alfred Grützner, Frank Langlotz, Guoyan Zheng, Jan Von Recum, Christina Keil, Lutz P. Nolte, Andreas Wentzensen & Klaus Wendl. (2005) Computer-assisted LISS plate osteosynthesis of proximal tibia fractures: Feasibility study and first clinical results. Computer Aided Surgery 10:3, pages 141-149.
Read now
Ofer Ron, Leo Joskowicz, Charles Milgrom & Ariel Simkin. (2002) Computer-Based Periaxial Rotation Measurement for Aligning Fractured Femur Fragments from CT: A Feasibility Study. Computer Aided Surgery 7:6, pages 332-341.
Read now
R. Hofstetter, M. Slomczykowski, C. Krettek, G. Köppen, M. Sati, L.-P. Nolte & Maurice E. Müller. (2000) Computer-Assisted Fluoroscopy-Based Reduction of Femoral Fractures and Antetorsion Correction. Computer Aided Surgery 5:5, pages 311-325.
Read now

Articles from other publishers (38)

Torsten Pastor, Tatjana Pastor, Philipp Kastner, Firas Souleiman, Matthias Knobe, Boyko Gueorguiev, Markus Windolf & Jan Buschbaum. (2022) Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking. Medicina 58:6, pages 773.
Crossref
Mohammadreza Maleki, Alireza Fadaei Tehrani, Ayda Aray & Mehdi Ranjbar. (2021) Intramedullary nail holes laser indicator, a non-invasive technique for interlocking of intramedullary nails. Scientific Reports 11:1.
Crossref
Jihun Yu, Hoseob Song, Chul-woo Park, Ilhyung Park & Sanghyun Joung. (2020) Fluoroscopic images-based aiming and targeting system with two line lasers for insertion guidance of interlocking screw. International Journal of Computer Assisted Radiology and Surgery 15:6, pages 1001-1012.
Crossref
Xiangqian Chen, Yu Wang, Gang Zhu, Weijun Zhang, Gang Zhou & Yubo Fan. (2020) Influence of multi-angle input of intraoperative fluoroscopic images on the spatial positioning accuracy of the C-arm calibration-based algorithm of a CAOS system. Medical & Biological Engineering & Computing 58:3, pages 559-572.
Crossref
Junqiang Wang, Yu Wang, Gang Zhu, Xiangqian Chen, Xiangrui Zhao, Huiting Qiao & Yubo Fan. (2018) Influence of the quality of intraoperative fluoroscopic images on the spatial positioning accuracy of a CAOS system. The International Journal of Medical Robotics and Computer Assisted Surgery 14:3.
Crossref
Delaram Behnami, Alireza Sedghi, Emran Mohammad Abu Anas, Abtin Rasoulian, Alexander Seitel, Victoria Lessoway, Tamas Ungi, David Yen, Jill Osborn, Parvin Mousavi, Robert Rohling & Purang Abolmaesumi. (2017) Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine. International Journal of Computer Assisted Radiology and Surgery 12:6, pages 973-982.
Crossref
Yanbin Zhu, Hengrui Chang, Yiyang Yu, Wei Chen, Song Liu & Yingze Zhang. (2016) Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures. International Orthopaedics 41:5, pages 1041-1048.
Crossref
P. Persiani, M. Gurzi, O. Moreschini, G. Di Giacomo & C. Villani. (2016) Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail. MUSCULOSKELETAL SURGERY 101:1, pages 19-23.
Crossref
Guoyan Zheng & Lutz P. Nolte. (2015) Computer-Assisted Orthopedic Surgery: Current State and Future Perspective. Frontiers in Surgery 2.
Crossref
Changsheng Li, Tianmiao Wang, Lei Hu, Lihai Zhang, Hailong Du, Lu Zhao, Lifeng Wang & Peifu Tang. (2015) A visual servo-based teleoperation robot system for closed diaphyseal fracture reduction. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 229:9, pages 629-637.
Crossref
Guoyan Zheng & Lutz-P. Nolte. 2014. Intraoperative Imaging and Image-Guided Therapy. Intraoperative Imaging and Image-Guided Therapy 647 659 .
Meghan C. Crookshank, Maarten Beek, Devin Singh, Emil H. Schemitsch & Cari M. Whyne. (2013) Can a semi-automated surface matching and principal axis-based algorithm accurately quantify femoral shaft fracture alignment in six degrees of freedom?. Medical Engineering & Physics 35:7, pages 1028-1036.
Crossref
Ioannis Stathopoulos, Panagiotis Karampinas, Dimitrios-Stergios Evangelopoulos, Kalliopi Lampropoulou-Adamidou & John Vlamis. (2013) Radiation-free distal locking of intramedullary nails: Evaluation of a new electromagnetic computer-assisted guidance system. Injury 44:6, pages 872-875.
Crossref
Shaolong Kuang, Kwok-sui Leung, Tianmiao Wang, Lei Hu, Elvis Chui, Wenyong Liu & Yu Wang. (2012) A novel passive/active hybrid robot for orthopaedic trauma surgery. The International Journal of Medical Robotics and Computer Assisted Surgery 8:4, pages 458-467.
Crossref
Erin J. Smith, Hisham A. Al-Sanawi, Braden Gammon, Paul J. St. John, David R. Pichora & Randy E. Ellis. (2011) Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation. International Journal of Computer Assisted Radiology and Surgery 7:3, pages 433-444.
Crossref
K. Dresing. (2011) R?ntgen in Unfallchirurgie und Orthop?dieX-ray in trauma and orthopedic surgery. Operative Orthop?die und Traumatologie 23:1, pages 70-78.
Crossref
Johannes Frank, Bernd Gritzbach, Christian Winter, Bernd Maier & Ingo Marzi. (2010) Computer-assisted Femur Fracture Reduction. European Journal of Trauma and Emergency Surgery 36:2, pages 151-156.
Crossref
John T. Riehl & James C. Widmaier. (2009) Techniques of Obtaining and Maintaining Reduction During Nailing of Femur Fractures. Orthopedics 32:8, pages 581-588.
Crossref
Laurent Mundeleer, David Wikler, Thierry Leloup & Nadine Warzée. (2008) Development of a computer assisted system aimed at RFA liver surgery. Computerized Medical Imaging and Graphics 32:7, pages 611-621.
Crossref
T. Leloup, W. El Kazzi, F. Schuind & N. Warzee. (2008) A Novel Technique for Distal Locking of Intramedullary Nail Based on Two Non-constrained Fluoroscopic Images and Navigation. IEEE Transactions on Medical Imaging 27:9, pages 1202-1212.
Crossref
Michael J. Gardner, Musa Citak, Daniel Kendoff, Christian Krettek & Tobias H?fner. (2008) Femoral fracture malrotation caused by freehand versus navigated distal interlocking. Injury 39:2, pages 176-180.
Crossref
G Zheng, X Dong & P A Gruetzner. (2008) Reality-augmented virtual fluoroscopy for computer-assisted diaphyseal long bone fracture osteosynthesis: A novel technique and feasibility study results. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 222:1, pages 101-115.
Crossref
Guoyan Zheng, Xiao Dong, Paul Alfred Grutzner & Lutz-Peter Nolte. (2007) Automated detection and segmentation of cylindrical fragments from calibrated C-arm images for long bone fracture reduction. Computer Methods and Programs in Biomedicine 87:1, pages 1-11.
Crossref
Ulrich Stöckle, Klaus Schaser & Benjamin König. (2007) Image guidance in pelvic and acetabular surgery—Expectations, success and limitations. Injury 38:4, pages 450-462.
Crossref
G. Zheng, X. Zhang, X. Dong, S. Sagbo, P. A. Grützner & F. Langlotz. 2007. Navigation and MIS in Orthopedic Surgery. Navigation and MIS in Orthopedic Surgery 496 500 .
K.W. Chong, M.K. Wong, I.S. Rikhraj & T.S. Howe. (2006) The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures—The experience in Singapore. Injury 37:8, pages 755-762.
Crossref
G.M. Whatling & L.D.M. Nokes. (2006) Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury 37:2, pages 109-119.
Crossref
A. Lerner, A. Chezar, M. Haddad, H. Kaufman, N. Rozen & H. Stein. (2005) Complications encountered while using thin-wire-hybrid-external fixation modular frames for fracture fixation. Injury 36:5, pages 590-598.
Crossref
Ming-Yih Lee, Chung-Hsien Kuo & Shuo-Suei Hung. (2005) Hands-on practice and implementations on a sound-guided 3D navigation system for orthopedic surgical applications. Hands-on practice and implementations on a sound-guided 3D navigation system for orthopedic surgical applications.
Th. Leloup, W.E. Kazzi, O. Debeir, F. Schuind & N. Warzee. (2005) Automatic fluoroscopic Image Calibration for Traumatology Intervention Guidance. Automatic fluoroscopic Image Calibration for Traumatology Intervention Guidance.
Norbert Suhm, Peter Messmer, Ivan Zuna, Ludwig A Jacob & Pietro Regazzoni. (2004) Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. Injury 35:6, pages 567-574.
Crossref
P. A. Grützner, B. Vock & A. Wentzensen. (2003) Klinische Anwendung C-Arm-basierter registrierungsfreier Navigation. Aktuelle Traumatologie 33:04, pages 175-182.
Crossref
Frank Langlotz & Lutz-Peter Nolte. (2003) Computer-Assisted Orthopaedic Surgery. Techniques in Orthopaedics 18:2, pages 140-148.
Crossref
N Suhm, P Mueller, M Hehli, S Koller, U Bopp, A.L Jacob, P Regazzoni & P Messmer. (2003) Adapting the fluoroscope to image-guided surgery. Injury 34:4, pages 307-311.
Crossref
A. Hebecker. 2003. Navigation und Robotic in der Gelenk- und Wirbelsäulenchirurgie. Navigation und Robotic in der Gelenk- und Wirbelsäulenchirurgie 29 35 .
F.-W. Hagena, M. Kettrukat & R. Christ. 2003. Navigation und Robotic in der Gelenk- und Wirbelsäulenchirurgie. Navigation und Robotic in der Gelenk- und Wirbelsäulenchirurgie 256 261 .
Frank Langlotz. (2002) State‐of‐the‐art in orthopaedic surgical navigation with a focus on medical image modalities. The Journal of Visualization and Computer Animation 13:1, pages 77-83.
Crossref
N. Suhm. (2001) Intraoperative accuracy evaluation of virtual fluoroscopy?A method for application in computer-assisted distal locking. Computer Aided Surgery 6:4, pages 221-224.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.